1. Product Introduction
Welcome to the HHJ series solar controller. This controller represents advanced innovation in the field of solar technology and is designed to provide exceptional performance and reliability for your solar energy system. The controller is equipped with advanced CNC technology, an LCD display, automated operation, and a Maximum Power Point Tracking (MPPT) battery charging mode. Combined with advanced control technology, it significantly extends the lifespan of your batteries.
The HHJ series solar controller is designed to meet the diverse needs of various solar energy systems, whether in standalone systems or other application scenarios. It automatically controls the charging and discharging processes. By optimizing the controller's battery charging and discharging processes, it not only prolongs the battery's lifespan but also enhances the overall system's performance. The controller features self-diagnostic functions and electronic protection, effectively preventing damage to the controller or batteries during installation errors or system faults, ensuring system reliability and stability.
Our HHJ series solar controllers are suitable for a wide range of solar energy applications. We offer a user-friendly custom open-program configuration interface, making the configuration process of solar energy systems quicker and smoother. It also provides more possibilities for expanding solar energy systems. Whether you are setting up a small-scale residential standalone solar system or expanding your solar energy project, the HHJ series solar controller will be an indispensable partner.
By choosing the HHJ series solar controller, you will gain an efficient, sustainable, and secure energy management solution that provides strong support for future energy needs. We are committed to advancing solar technology and delivering outstanding products and services to you.
Figure 1: PowMr HHJ60-PRO MPPT Solar Charge Controller highlighting key features.
2. Features
- Integrated Charging Presets: Adaptive charging logic suitable for most battery types (flooded lead-acid, gel-sealed lead-acid, lithium).
- Versatile Application: Compatible with 12V/24V/36V/48V system voltages.
- Multi-Stage Charging Algorithm: Optimizes each charging cycle and maintains battery capacity.
- Maximum Power Point Tracking (MPPT) Technology: Tracks Vmp for maximum power collection with 99.9% tracking efficiency and up to 97% peak conversion efficiency.
- Supports Up to 12 Units in Parallel: Allows easy expansion of solar panel configuration and energy storage capacity.
- Adaptive Boost Charging: Monitors battery response and determines boost stage duration to ensure full charge without overcharging.
- Durable and Secure: Includes photovoltaic input overcurrent, photovoltaic array short circuit, and reversed photovoltaic polarity protection.
- External Temperature Probe Configuration: Precisely monitors battery temperature, stopping charging if it exceeds 65°C and resuming below 55°C.
- Forced Air Cooling: Built-in cooling fan for efficient heat dissipation.
- Lithium Battery Activation: Compatible with lithium batteries, adjusting charging cycles and activating protected lithium batteries using solar panel energy.
Figure 2: Illustration of the 4-stage PWM charging process.
3. Product Appearance
Figure 3: Front view of the PowMr MPPT Solar Controller.
Figure 4: Back view of the PowMr MPPT Solar Controller with heat fins.
Figure 5: Dimensions of the PowMr MPPT Solar Controller.
3.1. Component Identification
| No. | Component | No. | Component |
|---|---|---|---|
| 1 | LCD display | 5 | Load port |
| 2 | Function key | 6 | Temperature probe port |
| 3 | PV input port | 7 | Parallel communication port |
| 4 | Battery port |
4. Important Safety Instructions
WARNING: Carefully read and adhere to all safety instructions.
- Before installing and operating the controller, please read the user manual thoroughly and keep it for future reference.
- The installation or operation of the controller should only be performed by individuals who have received proper training and supervision.
- Anyone lacking the necessary knowledge, experience, or capabilities for the safe installation and operation requirements should not attempt installation.
- Individuals (including children) who may have physical, sensory, or intellectual impairments that could affect the safe installation and operation should not attempt installation.
4.1. Controller Installation and Operation Safety
- This controller product does not have user-serviceable components; do not disassemble or attempt to repair the controller yourself.
- Install the controller in a well-ventilated environment with adequate clearance around it.
- Install the controller on non-combustible walls and ensure there are no flammable materials nearby; it is normal for the controller to generate heat during operation.
- Place the controller in an environment that is protected from direct sunlight, rain, humidity, and dust, and keep it away from any flammable liquids or gases. The controller is for indoor use only.
- Do not install or operate the controller on top of, directly above, or in an enclosed space above batteries, as batteries emit explosive gases.
- Do not place any objects on top of the controller.
4.2. Battery Installation and Charging Safety
- Install and charge batteries in well-ventilated or exhaust-ventilated environments.
- Ensure there are no open flames in the vicinity of the batteries, as batteries emit explosive gases.
- Battery acid is corrosive; if battery acid comes into contact with the skin, rinse immediately with clean water.
- Do not charge non-rechargeable batteries. Do not charge lithium batteries when the temperature is below 0°C. Charging frozen batteries is prohibited.
- Ensure that the equipment is properly configured for the type of battery connected to it.
4.3. DC Battery Connections Safety
- Ensure that the DC system is fully off/powered down by disconnecting all cables and/or new ports from the battery/DC system.
- Use flexible, multi-strand copper cables with an appropriate cross-sectional area, and connect them to matching fuses or circuit breakers.
- Connecting the photovoltaic array to the controller is prohibited until the battery is connected first.
4.4. Controller Configuration Safety
- Refer to the battery manufacturer's guide and specifications to ensure the battery is suitable for the controller and confirm the recommended charging settings.
- Integrated charging modes include adaptive charging logic, which is suitable for most battery types.
5. Installation and Wiring
5.1. Unpacking and Inspection
Before unpacking, inspect the packaging for any signs of damage. After unpacking, check the contents to ensure nothing is damaged or missing. Inside the package, you will find the following items:
- Controller device
- External temperature probe
- Parallel connection terminal
- Set of installation screws
- User Manual
Video 1: Unboxing and overview of the HHJ60-PRO solar charge controller package contents.
5.2. Choosing the Installation Location
Several aspects should be considered to determine or provide a suitable and safe installation location:
- Install the controller in a space with good natural ventilation/exhaust.
- Avoid direct sunlight.
- Ensure there is ample clearance around the controller. The minimum clearance at the top, bottom, and both sides of the controller is 75mm.
- Install the controller on a non-combustible wall and ensure there are no flammable materials nearby; an increase in temperature during controller operation is a normal occurrence.
- When running multiple controllers in parallel, ensure they are installed at the same horizontal height, with a minimum spacing of 75mm between controllers.
5.3. Wiring Precautions
- Installation and wiring work should be carried out by a certified electrician.
- Wiring should follow the sequence of Battery > PV Input > Load.
- To avoid short-circuits and polarity reversal, pay attention to connecting the positive (+) cable to the device's positive (+) terminal and the negative (-) cable to the device's negative (-) terminal.
- Loose and/or incomplete connections can lead to cable or terminal overheating. Therefore, tighten all cables to minimize transition resistance, using cable sizes appropriate for the specific circuit's current rating.
- Do not connect the inverter to the load terminal of the controller, as doing so may result in irreversible damage to the equipment. If it is necessary to connect the inverter, please follow the battery connection steps outlined in Section 5.4, as indicated in the wiring diagram.
5.4. Installation and Wiring Guidelines
Please refer to the following steps to complete the installation and wiring of the controller. A full user manual is available in PDF format: PowMr HHJ60-PRO User Manual (PDF).
Step 1. Controller Mounting
Install the controller vertically with its ports facing downward, securing it to the wall through the four mounting holes using screws. For ease of installation, it is recommended to use two upper screws for initial "hanging" of the device, followed by the addition of two lower screws, and then fully tighten all four screws.
Figure 6: Controller mounting diagram.
Step 2. Battery Wiring
Connect the battery to the controller using cables.
Attention: Do not connect the inverter to the load terminal of the controller; otherwise, it may cause irreversible damage to the equipment. If it is necessary to connect the inverter, please refer to the diagram below.
Figure 7: Battery wiring diagram.
NOTE:
- All wiring work must be carried out by professionals.
- For safe operation and proper application, circuit breakers of the appropriate specifications must be installed on the cables connected to the controller, and ensure that the connections are tight.
- Ensure that all circuit breakers are in the off position before completing all wiring.
- Connect the positive cable terminal to the positive terminal port, and the negative cable terminal to the negative terminal port.
- The above notes also apply to the PV ports and DC output ports.
Step 3. PV Wiring
Connect the photovoltaic array to the controller using cables.
Figure 8: PV array wiring diagram.
Step 4. DC Output Wiring
Connect the load to the controller using cables.
Figure 9: DC output wiring diagram.
Step 5. Temperature Probe Connection
Connect the temperature probe wire to the controller and securely fix the probe end to the battery using insulation tape.
Figure 10: Temperature probe connection.
Step 6. Pre-Startup Check
Refer to the wiring diagrams. If all connections are accurate, and all wiring is securely connected, close the circuit breakers in the order of Battery, PV Input, and Load terminals.
WARNING: Risk of Electric Shock! Before wiring, ensure that all power sources are turned off and follow the relevant inspection and operation procedures.
6. Operation Guide
6.1. Key Introduction
Figure 11: LCD display and control buttons.
| Function key | Description |
|---|---|
| PRG/ESC | Enter the setup program / Exit the setup program |
| ▲ | Enter the next item/Increase value |
| ▼ | Return to the previous item/ Decrease value |
| ENTER | Confirmation button |
6.2. Main Page Overview
The LCD display shows various parameters. Here's a breakdown of the main pages:
| Page | Description |
|---|---|
| 1 | PV Voltage / Output Power |
| 2 | Battery Voltage / Charging Current |
| 3 | Operating Mode / Temperature |
| 4 | Fault Codes/Parallel Operation Code |
6.3. Operating Modes
| Mode Codes | Description |
|---|---|
| 3.0 | Night Mode, No Charging |
| 4.0 | MPPT Mode |
| 7.0 | Boost Charging Mode (Constant Voltage Charging) |
| 8.0 | Float Charging Mode |
6.4. Overview of the Settings Page
On the main screen, press the PRG button to access the settings page. Use the ▲ and ▼ buttons to navigate through the settings items, then press the ENT button to enter the settings for the selected item. Within a setting item, use the ▲ or ▼ buttons to adjust the numerical values or toggle options. Finally, press the ENT button to save the settings. After configuring all the settings items, press the ESC button to exit the settings page.
6.5. Setting Guidelines
D00 Load Operation Mode Setting
Configure the mode and duration for enabling the load output:
- 1.00H: Light control mode. (Loads start to supply power after dark and stop working after dawn.)
- 2.24H (Default): Immediate load activation.
- 3.01H~23H: Adjust the duration for load activation.
D01 Float Charge Voltage Setting
After the boost charge phase, the controller will reduce the battery voltage by decreasing the charging current and maintain the battery at the float charge voltage setting value to keep the battery in a fully charged state. Please adjust this setting based on the charging parameters of the connected batteries.
D02 Boost Charge Voltage Setting
During the boost charge phase, the battery will be charged at a constant preset voltage value. Please set this value according to the specific charging parameters of your batteries.
D03 Low Voltage Disconnect Setting
When the battery voltage falls below the value set in D03, the controller will stop discharging the battery to prevent over-discharging.
D04 Voltage Calibration Setting
This setting allows you to calibrate the displayed battery voltage when there is a difference between the controller's detected voltage and the voltage measured with a multimeter. Please note that using excessively long or thin cables can affect the controller's ability to accurately read the battery voltage.
D05 Parallel Communication Code Setting
NOTICE: This program requires no configuration if you are not operating in parallel mode.
After completing the parallel wiring, you can use the D05 setting program to define the master and slave controllers. The controller with the lowest communication code value will be the master. In parallel operation, if the master encounters an issue, the system will automatically select the controller with the next code value as the new master. For example, if the No. 01 master fails, the system will designate No. 02 as the new master.
Assuming six controllers are operating in parallel:
| Scenario | 01 | 02 | 03 | 04 | 05 | 06 |
|---|---|---|---|---|---|---|
| Scenario 1: Normal operation | Master | Slave | Slave | Slave | Slave | Slave |
| Scenario 2: No. 01 failure | Fault | Master | Slave | Slave | Slave | Slave |
| Scenario 3: No. 03 failure | Master | Slave | Fault | Slave | Slave | Slave |
| Scenario 4: No. 01 & 02 failures | Fault | Fault | Master | Slave | Slave | Slave |
D06 Battery Type Setting
| Display | Battery Type |
|---|---|
| SEL | Lead-acid Battery (Default) |
| GEL | Gel Sealed Lead-acid Battery |
| FLd | Flooded Lead-acid Battery |
| L04 | 4-Cell Lithium Iron Phosphate Battery |
| L08 | 8-Cell Lithium Iron Phosphate Battery |
| L15 | 15-Cell Lithium Iron Phosphate Battery |
| L16 | 16-Cell Lithium Iron Phosphate Battery |
| USE | Custom Battery Type |
Battery Charging Voltage Reference
| Battery Type | Float Charging Voltage | Boost Charging Voltage | Undervoltage Protection Voltage |
|---|---|---|---|
| SEL | 13.8 | 14.4 | 11.0 |
| GEL | 13.8 | 14.2 | 11.0 |
| FLd | 13.8 | 14.6 | 11.0 |
| L04 | 13.8 | 14.5 | 11.2 |
| L08 | 27.6 | 29.0 | 22.4 |
| L15 | 51.8 | 54.4 | 42.0 |
| L16 | 55.2 | 58.0 | 44.8 |
| USE | User-defined | ||
D07 System Voltage Setting
If D06 is set to USE, it will enter D07 to select the system voltage. If D06 is not set to USE, the system will automatically detect the system voltage of the connected battery and will not enter D07 setting program. The system voltage configuration range is 12V/24V/36V/48V.
7. Parallel Operation Guide
The controller device is capable of standalone operation for individual units and can also support a maximum of 12 units in parallel operation. When operating in parallel, communication between the parallel controllers is achieved through communication lines. The parallel controllers are installed at the same horizontal height.
7.1. Main Modules
- Controller: Each unit can operate standalone or in parallel (up to 12 units).
- Solar Array: Each controller must be connected to a separate solar array. One solar array cannot be simultaneously connected to more than one controller. The input power connected to each controller should not exceed the rated input power of a single controller.
- Battery Bank: Parallel controllers are connected to the same battery bank.
7.2. Parallel Operation Schematic
Figure 12: Parallel operation schematic.
7.3. Parallel Installation and Wiring
You can view the parallel operation guide by scanning the QR code in the full user manual PDF.
- Install parallel devices at the same height level with a minimum distance of approximately 75mm between devices.
- Connect communication lines.
- Connect all parallel controllers to the same battery bank in sequence.
- Then, individually connect each controller to its respective photovoltaic array.
- Finally, connect each controller to the DC load.
- Set the parallel operation code for each controller, as detailed in Section 6.5 (D05 Parallel Communication Code Setting).
Figure 13: Parallel installation diagram.
8. Protection Function
| Protection | Description |
|---|---|
| Photovoltaic Input Overcurrent | The controller limits the battery charging current to the maximum battery current rating. Consequently, an overcurrent from the photovoltaic array input will not allow it to operate at peak power. |
| Photovoltaic Array Short Circuit | When a short circuit occurs in the photovoltaic array, the controller will stop charging, and operation can be restored by eliminating the short circuit fault. |
| Photovoltaic Polarity Reversal | If the photovoltaic input wiring polarity is reversed, the controller will not operate, and it will not damage the controller. After proper reconnection, the controller will operate normally. |
| Battery Overvoltage | When the battery voltage exceeds 15.5/31.0/46.5/62.0V, the controller will stop charging to protect the battery from overcharging damage. Please note that stopping the charging means the charging current is very low. |
| Battery Over-discharge | When the battery voltage drops to the low-voltage disconnect setpoint, the controller will stop discharging to protect the battery from over-discharge damage. |
| Over-temperature Protection | When the battery temperature drops to the low-voltage disconnect setpoint, the controller will stop discharging to protect the battery from over-discharge damage. |
9. Troubleshooting
| Fault Code | Description | Resolution |
|---|---|---|
| 18 | Photovoltaic Input Voltage Too Low | Increase the photovoltaic array voltage by changing the series-parallel connection or adding more solar panels. |
| 60 | Over-temperature Protection | In case of over-temperature, the fan will start automatically to provide efficient forced cooling. |
| 63 | Battery Overvoltage | Charging will automatically stop, and it will resume when the battery voltage returns to normal levels. |
| 65 | Battery Undervoltage | Discharging will automatically stop, and it will resume when the battery voltage rises to normal levels. |
| 71 | Photovoltaic Input Voltage Too High | Reduce the photovoltaic array voltage by changing the series-parallel connection or reducing the number of solar panels. |
| 73 | Overcharging Current | Reduce the photovoltaic input power by decreasing the number of solar panels. |
10. Maintenance
We recommend conducting the following checks and maintenance at least twice a year to ensure optimal performance:
- Ensure the controller is securely mounted in a clean and dry environment.
- Ensure proper airflow around the controller and clean any dust or debris from the heat sinks.
- Inspect all exposed wires for insulation damage, such as severe sun exposure, friction wear, dryness, insect or rodent damage. Repair or replace any damaged wires as necessary.
- Tighten all terminals and check for loose, broken, or burnt cable connections.
- Confirm that all system components are properly grounded.
- Ensure all terminals are free from corrosion, insulation damage, high temperatures, or signs of burning/discoloration, and tighten terminal screws.
- Check for dirt, nesting insects, and corrosion. If present, clean promptly.
WARNING: Risk of electric shock! Before performing the above operations, ensure that all power sources are turned off and then follow the relevant check and operation guidelines.
11. Specification Parameters
| Models | HHJ60-PRO | |
|---|---|---|
| Solar Input Parameters | ||
| Max. Solar Array Open-Circuit Voltage | 160V | |
| Maximum Input Power: | For 12V System | 720W |
| For 24V System | 1440W | |
| For 36V System | 2100W | |
| For 48V System | 2800W | |
| Input Voltage Range: | For 12V System | 20V~80V |
| For 24V System | 37V~105V | |
| For 36V System | 50V~160V | |
| For 48V System | 72V~160V | |
| Battery Charging Parameters | ||
| Charging Technology | MPPT | |
| Charging Algorithm | 3 stages | |
| Battery Voltage Auto-Detection | 12V System | DC9V~DC15V |
| 24V System | DC18V~DC29V | |
| 36V System | DC30V~DC39V | |
| 48V System | DC40V~DC60V | |
| Overcharge Protection Voltage | 60V | |
| Charging Limit Current | 61A | |
| Maximum Efficiency | ≥98.1% | |
| Solar Utilization Rate | ≥99% | |
| Load Terminal Output | ||
| Rated Output Current | 6A | |
| Protection | ||
| Temperature Protection | 75°C / 167 °F | |
| Fan Start Temperature | >45°C / 104°F | |
| Fan Shutdown Temperature | <40°C / 95°F | |
| General Specification | ||
| Dimensions | 215x130x85mm / 8.46x5.12x3.35in | |
| Net Weight | 990g / 2.18lb | |
| Electromagnetic Compatibility | EN61000, EN55022, EN55024 | |
| Protection Level | IP21 | |
| Operating Temperature | -20°C ~ +55°C / -4°F ~ 131°F | |
| Storage Temperature | -40°C ~ +75°C / -40°F ~ 167°F | |
12. User Tips
- Always verify the wattage output, especially when connecting to an inverter, to ensure it meets your expectations and avoid potential damage.
- If you encounter issues with the inverter not delivering expected wattage, contact support. They may offer solutions or compensation without requiring a return.
- Ensure proper packaging for transit to prevent damage to the unit.
13. Frequently Asked Questions (FAQ)
- Q: Does this charge controller support LiFePO4 batteries?
- A: Yes, this charge controller supports LiFePO4 batteries. Refer to Section 6.5, D06 Battery Type Setting, for specific configurations.
- Q: Why does the charger block with two 550W panels in parallel (45V, 36A max)?
- A: This could be due to the photovoltaic input voltage being too high or overcurrent. Please check the troubleshooting section (Section 9, Fault Code 71 and 73) and ensure your panel configuration does not exceed the controller's maximum input voltage (160V) or charging limit current (61A). You may need to adjust the series-parallel connection or reduce the number of solar panels.
- Q: Does it fit for Nickel Cadmium batteries?
- A: The manual specifies compatibility with flooded lead-acid, gel-sealed lead-acid, and lithium batteries, and offers custom battery type settings. It does not explicitly mention Nickel Cadmium batteries. Please refer to the battery manufacturer's guide and specifications to ensure compatibility and proper charging settings, or use the custom setting option if applicable.
14. Warranty and Support
14.1. Warranty Services
Thank you for choosing the HHJ series solar controller. Please carefully read this manual as it will help you maximize the many advantages the controller offers for your solar system.
This manual provides important recommendations regarding installation and usage. For your own benefit, please read and pay close attention to the safety advice within.
In accordance with the instructions, repair services may be provided to users for any damaged units resulting from incorrect installation, disassembly, or improper use of this product.
Warranty Terms:
- Within 30 days from the date of purchase, a malfunctioning controller will be replaced at no charge, provided that it has been used under normal circumstances and authorized by the company's technical personnel.
- Within 2 years from the date of purchase, a malfunctioning controller will be repaired at no charge.
NOTE: Unauthorized disassembly voids the warranty.
Declaration (Circumstances Not Covered by Warranty):
Under the following circumstances, our company reserves the right not to assume any quality warranty responsibilities:
- Damage caused by improper transportation.
- Damage resulting from incorrect storage, installation, or usage.
- Damage caused by non-professionals or untrained personnel installing and operating the equipment.
- Damage resulting from non-compliance with the instructions and safety warnings in this document.
- Damage caused by operation in environments that do not meet the requirements specified in this document.
- Damage due to operation beyond the parameter ranges specified in applicable technical specifications.
- Damage resulting from unauthorized disassembly, product alteration, or software code modification.
- Damage caused by abnormal natural conditions (force majeure), such as lightning, earthquakes, fires, storms, etc.
- Any damage resulting from failure to adhere to local standards and regulations during the installation and operation processes.
- Products outside the warranty period.
14.2. Contact Information
SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
- Tel/Fax: +86 755-28219903
- Email: support@powmr.com
- Web: www.powmr.com
- Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China