1. Product Introduction
Welcome to the HHJ series solar controller. This controller represents advanced innovation in the field of solar technology and is designed to provide exceptional performance and reliability for your solar energy system. The controller is equipped with advanced CNC technology, an LCD display, automated operation, and a Maximum Power Point Tracking (MPPT) battery charging mode. Combined with advanced control technology, it significantly extends the lifespan of your batteries.
The HHJ series solar controller is designed to meet the diverse needs of various solar energy systems, whether in standalone systems or other application scenarios. It automatically controls the charging and discharging processes. By optimizing the controller's battery charging and discharging processes, it not only prolongs the battery's lifespan but also enhances the overall system's performance. The controller features self-diagnostic functions and electronic protection, effectively preventing damage to the controller or batteries during installation errors or system faults, ensuring system reliability and stability.
Our HHJ series solar controllers are suitable for a wide range of solar energy applications. We offer a user-friendly custom open-program configuration interface, making the configuration process of solar energy systems quicker and smoother. It also provides more possibilities for expanding solar energy systems. Whether you are setting up a small-scale residential standalone solar system or expanding your solar energy project, the HHJ series solar controller will be an indispensable partner.
By choosing the HHJ series solar controller, you will gain an efficient, sustainable, and secure energy management solution that provides strong support for future energy needs. We are committed to advancing solar technology and delivering outstanding products and services to you.
Key Features:
- MPPT Technology: Built-in Maximum Power Point Tracking (MPPT) technology with 99.9% tracking efficiency and up to 97% peak conversion efficiency.
- System Voltage: Suitable for 12V, 24V, 36V, and 48V energy storage systems.
- Multi-Stage Charging: Features a three-stage charging algorithm (Boost, Bulk, Float) and presets for quick and safe configuration for different battery types, ensuring efficient charging and extending battery life.
- Parallel Operation: Supports up to 12 units in parallel for easy energy capacity expansion.
- Multiple Protections: Includes overvoltage, over-temperature, reversed PV polarity, overdischarge, and short circuit protection.
- Battery Compatibility: Compatible with various battery types including Vented, Sealed, Gel, NiCd, and Lithium batteries.
- Efficient Cooling: Dual cooling system with a quiet bladeless fan and robust die-cast aluminum heat sink for efficient heat dissipation.
Product Overview Video
This video provides an unboxing and overview of the HHJ60-PRO solar charge controller, highlighting its key features and components.
2. Important Safety Instructions
WARNING: Carefully read and adhere to all safety instructions.
- Before installing and operating the controller, please read the user manual thoroughly and keep it for future reference.
- The installation or operation of the controller should only be performed by individuals who have received proper training and supervision. This includes individuals with the necessary knowledge, experience, or capabilities for safe installation and operation, and excludes individuals (including children) who may have physical, sensory, or intellectual impairments that could affect safe installation and operation.
2.1 Controller Installation and Operation Safety
- This controller product does not have user-serviceable components; do not disassemble or attempt to repair the controller yourself.
- Install the controller in a well-ventilated environment with adequate clearance around it.
- Install the controller on non-combustible walls and ensure there are no flammable materials nearby; it is normal for the controller to generate heat during operation.
- Place the controller in an environment that is protected from direct sunlight, rain, humidity, and dust, and keep it away from any flammable liquids or gases. The controller is for indoor use only.
- Do not install or operate the controller on top of, directly above, or in an enclosed space above batteries, as batteries emit explosive gases.
- Do not place any objects on top of the controller.
2.2 Battery Installation and Charging Safety
- Install and charge batteries in well-ventilated or exhaust-ventilated environments.
- Ensure there are no open flames in the vicinity of the batteries, as batteries emit explosive gases.
- Battery acid is corrosive; if battery acid comes into contact with the skin, rinse immediately with clean water.
- Do not charge non-rechargeable batteries. Do not charge lithium batteries when the temperature is below 0°C. Charging frozen batteries is prohibited.
- Ensure that the equipment is properly configured for the type of battery connected to it.
2.3 DC Battery Connections Safety
- Ensure that the DC system is fully off/powered down by disconnecting all cables and/or new ports from the battery/DC system.
- Use flexible, multi-strand copper cables with an appropriate cross-sectional area, and connect them to matching fuses or circuit breakers.
- Connecting the photovoltaic array to the controller is prohibited until the battery is connected first.
2.4 Controller Configuration Safety
- Refer to the battery manufacturer's guide and specifications to ensure the battery is suitable for the controller and confirm the recommended charging settings.
- Integrated charging modes include adaptive charging logic, which is suitable for most battery types.
3. Product Appearance
The following diagram illustrates the main components and ports of the PowMr MPPT Solar Charge Controller.
Diagram of the PowMr MPPT Solar Controller, showing its front panel with LCD display and buttons, and the connection terminals at the bottom.
| No. | Component | No. | Component |
|---|---|---|---|
| 1 | LCD display | 5 | Load port |
| 2 | Function key | 6 | Temperature probe port |
| 3 | PV input port | 7 | Parallel communication port |
| 4 | Battery port |
4. Installation and Wiring
4.1 Unpacking and Inspection
Before unpacking, inspect the packaging for any signs of damage. After unpacking, check the contents to ensure nothing is damaged or missing. Inside the package, you will find the following items:
- Controller
- User Manual (this document)
- Installation screws
- Parallel connector
- External temperature sensor
4.2 Choosing the Installation Location
Before installation, several aspects should be considered to determine or provide a suitable and safe installation location:
- Install the controller in a space with good natural ventilation/exhaust.
- Avoid direct sunlight.
- Ensure there is ample clearance around the controller. The minimum clearance at the top, bottom, and both sides of the controller is 75mm.
- Install the controller on a non-combustible wall and ensure there are no flammable materials nearby; an increase in temperature during controller operation is a normal occurrence.
- Install the controller in an environment that avoids direct sunlight, rain, humidity, and dust, and keep it away from any flammable liquids or gases. The controller is for indoor use only.
- Do not install or operate the controller on top of, directly above, or in an enclosed space above batteries, as batteries emit explosive gases.
- When running multiple controllers in parallel, ensure they are installed at the same horizontal height, with a minimum spacing of 75mm between controllers.
4.3 Wiring Precautions
- Installation and wiring work should be carried out by a certified electrician.
- Wiring should follow the sequence of Battery > PV Input > Load.
- To avoid short-circuits and polarity reversal, pay attention to connecting the positive (+) cable to the device's positive (+) terminal and the negative (-) cable to the device's negative (-) terminal.
- Loose and/or incomplete connections can lead to cable or terminal overheating. Therefore, tighten all cables to minimize transition resistance, using cable sizes appropriate for the specific circuit's current rating.
- Do not connect the inverter to the load terminal of the controller, as doing so may result in irreversible damage to the equipment. If it is necessary to connect the inverter, please follow the battery connection steps outlined in Section 4.4, as indicated in the wiring diagram.
4.4 Installation and Wiring Guidelines
WARNING: Risk of Electric Shock! Before wiring, ensure that all power sources are turned off and follow the relevant inspection and operation procedures.
Step 1. Mount the Controller: Install the controller vertically with its ports facing downward, securing it to the wall through the four mounting holes using screws. For ease of installation, it is recommended to use two upper screws for initial "hanging" of the device, followed by the addition of two lower screws, and then fully tighten all four screws.
Diagram showing the vertical mounting of the controller to a wall using four screws.
Step 2. Battery Wiring: Connect the battery to the controller using cables. Ensure all circuit breakers are in the off position before wiring. Connect the positive cable terminal to the positive terminal port, and the negative cable terminal to the negative terminal port.
Attention: Do not connect the inverter to the load terminal of the controller; otherwise, it may cause irreversible damage to the equipment. If an inverter is needed, connect it directly to the battery bank.
Wiring diagram illustrating the connection of the battery to the solar charge controller, including an optional inverter connection to the battery.
Step 3. PV Wiring: Connect the photovoltaic array to the controller using cables. Ensure all circuit breakers are in the off position before wiring. Connect the positive PV cable to the positive PV input port, and the negative PV cable to the negative PV input port.
Wiring diagram showing the connection of the photovoltaic (solar) array to the solar charge controller via a breaker.
Step 4. DC Output Wiring: Connect the load to the controller using cables. Ensure all circuit breakers are in the off position before wiring. Connect the positive load cable to the positive load port, and the negative load cable to the negative load port.
Wiring diagram illustrating the connection of a DC load to the solar charge controller, including a fuse.
Step 5. Temperature Probe Connection: Connect the temperature probe wire to the controller and securely fix the probe end to the battery using insulation tape.
Diagram showing the connection of the external temperature probe to the controller and its placement on the battery.
Step 6. Pre-Startup Check: Refer to the wiring diagrams. If all connections are accurate, and all wiring is securely connected, close the circuit breakers in the order of Battery, PV Input, and Load terminals.
4.5 Parallel Installation and Wiring
The controller device is capable of standalone operation for individual units and can also support a maximum of 12 units in parallel operation. When operating in parallel, communication between the parallel controllers is achieved through communication lines. The parallel controllers are installed at the same horizontal height.
- Solar Array: Each controller must be connected to a separate solar array. One solar array cannot be simultaneously connected to more than one controller. The input power connected to each controller should not exceed the rated input power of a single controller.
- Battery Bank: Parallel controllers are connected to the same battery bank.
Parallel Installation Steps:
- Install parallel devices at the same height level with a minimum distance of approximately 75mm between devices.
- Connect communication lines.
- Connect all parallel controllers to the same battery bank in sequence.
- Then, individually connect each controller to its respective photovoltaic array.
- Finally, connect each controller to the DC load.
- Set the parallel operation code for each controller, as detailed in Section 5.5 (D05 Parallel Communication Code Setting).
Schematic diagram showing multiple solar charge controllers connected in parallel to separate solar arrays and a common battery bank.
5. Operation Guide
5.1 Key Introduction
The controller features an LCD display and several function keys for operation and configuration.
| Function Key | Description |
|---|---|
| PRG/ESC | Enter the setup program / Exit the setup program |
| Up Arrow (▲) | Enter the next item / Increase value |
| Down Arrow (▼) | Return to the previous item / Decrease value |
| ENTER | Confirmation button |
5.2 Main Page Overview
The main display shows key operational parameters:
- PV Input Voltage / Load Power Consumption: Displays the current photovoltaic input voltage and the power consumed by the load.
- Battery Voltage / Charging Current: Shows the current battery voltage and the charging current.
- Operation Mode / Device Temperature: Indicates the current operating mode and the internal temperature of the device.
- Fault Codes / Parallel Operation: Displays any active fault codes or the parallel operation status.
5.3 Operating Modes
The controller operates in various modes depending on the charging state:
| Mode Code | Description |
|---|---|
| 3.0 | Night Mode, No Charging |
| 4.0 | MPPT Mode |
| 7.0 | Boost Charging Mode (Constant Voltage Charging) |
| 8.0 | Float Charging Mode |
5.4 Overview of the Settings Page
On the main screen, press the PRG button to access the settings page. Use the Up (▲) and Down (▼) buttons to navigate through the settings items, then press the ENT button to enter the settings for the selected item. Within a setting item, use the Up (▲) or Down (▼) buttons to adjust the numerical values or toggle options. Finally, press the ENT button to save the settings. After configuring all the settings items, press the ESC button to exit the settings page.
5.5 Setting Guidelines
D00 Load Operation Mode Setting: Configure the mode and duration for enabling the load output.
- 1.00H: Light control mode (Loads start to supply power after dark and stop working after dawn).
- 2.24H (Default): Immediate load activation.
- 3.01H~23H: Adjust the duration for load activation.
D01 Float Charge Voltage Setting: After the boost charge phase, the controller will reduce the battery voltage by decreasing the charging current and maintain the battery at the float charge voltage setting value to keep the battery in a fully charged state. Adjust this setting based on the charging parameters of the connected batteries.
D02 Boost Charge Voltage Setting: During the boost charge phase, the battery will be charged at a constant preset voltage value. Set this value according to the specific charging parameters of your batteries.
D03 Low Voltage Disconnect Setting: When the battery voltage falls below this value, the controller will stop discharging the battery to prevent over-discharging.
D04 Voltage Calibration Setting: This setting allows you to calibrate the displayed battery voltage when there is a difference between the controller's detected voltage and the voltage measured with a multimeter. Note that using excessively long or thin cables can affect the controller's ability to accurately read the battery voltage.
D05 Parallel Communication Code Setting: This program requires no configuration if you are not operating in parallel mode. After completing parallel wiring, use the D05 setting program to define master and slave controllers. The controller with the lowest communication code value will be the master. If the master fails, the system automatically selects the controller with the next code value as the new master.
D06 Battery Type Setting: Select the battery type from the available options. If 'USE' (User-Defined) is selected, you will proceed to D07 to set the system voltage manually.
| Display | Battery Type |
|---|---|
| SEL | Sealed Lead Acid Battery (Default) |
| GEL | Gel Sealed Lead-acid Battery |
| FLd | Flooded Lead-acid Battery |
| L04 | 4-Cell Lithium Iron Phosphate Battery |
| L08 | 8-Cell Lithium Iron Phosphate Battery |
| L15 | 15-Cell Lithium Iron Phosphate Battery |
| L16 | 16-Cell Lithium Iron Phosphate Battery |
| USE | User-Defined |
D07 System Voltage Setting: If D06 is set to USE, you will enter D07 to select the system voltage. If D06 is not set to USE, the system will automatically detect the system voltage of the connected battery and will not enter the D07 setting program. The system voltage configuration range is 12V/24V/36V/48V.
6. Maintenance
We recommend conducting the following checks and maintenance at least twice a year to ensure optimal performance:
- Ensure the controller is securely mounted in a clean and dry environment.
- Ensure proper airflow around the controller and clean any dust or debris from the heat sinks.
- Inspect all exposed wires for insulation damage, such as severe sun exposure, friction wear, dryness, insect or rodent damage. Repair or replace any damaged wires as necessary.
- Tighten all terminals and check for loose, broken, or burnt cable connections.
- Confirm that all system components are properly grounded.
- Ensure all terminals are free from corrosion, insulation damage, high temperatures, or signs of burning/discoloration, and tighten terminal screws.
- Check for dirt, nesting insects, and corrosion. If present, clean promptly.
WARNING: Risk of electric shock! Before performing the above operations, ensure that all power sources are turned off and then follow the relevant check and operation guidelines.
7. Troubleshooting
Refer to the table below for common fault codes and their resolutions:
| Fault Code | Description | Resolution |
|---|---|---|
| 18 | Photovoltaic Input Voltage Too Low | Increase the photovoltaic array voltage by changing the series-parallel connection or adding more solar panels. |
| 60 | Over-temperature Protection | In case of over-temperature, the fan will start automatically to provide efficient forced cooling. |
| 63 | Battery Overvoltage | Charging will automatically stop, and it will resume when the battery voltage returns to normal levels. |
| 65 | Battery Undervoltage | Discharging will automatically stop, and it will resume when the battery voltage rises to normal levels. |
| 71 | Photovoltaic Input Voltage Too High | Reduce the photovoltaic array voltage by changing the series-parallel connection or reducing the number of solar panels. |
| 73 | Overcharging Current | Reduce the photovoltaic input power by decreasing the number of solar panels. |
8. Specifications
| Parameter Category | Parameter | Value (HHJ60-PRO) |
|---|---|---|
| Solar Input Parameters | Maximum Input Power (12V System) | 720W |
| Maximum Input Power (24V System) | 1440W | |
| Maximum Input Power (36V System) | 2100W | |
| Maximum Input Power (48V System) | 2800W | |
| Input Voltage Range (Voc) | 160VDC | |
| Battery Charging Parameters | Charging Technology | MPPT |
| Charging Algorithm | 3 stages | |
| Battery Voltage Auto-Detection (12V System) | DC9V~DC15V | |
| Battery Voltage Auto-Detection (24V System) | DC18V~DC29V | |
| Battery Voltage Auto-Detection (36V System) | DC30V~DC39V | |
| Battery Voltage Auto-Detection (48V System) | DC40V~DC60V | |
| Overcharge Protection Voltage | 60V | |
| Charging Limit Current | 61A | |
| Efficiency | Maximum Efficiency | ≥98.1% |
| Solar Utilization Rate | ≥99% | |
| Load Terminal Output | Rated Output Current | 6A |
| Maximum DC Output Current | 8A | |
| Protection | Temperature Protection | 75°C / 167°F |
| Fan Start Temperature | >45°C / 104°F | |
| Fan Shutdown Temperature | <40°C / 95°F | |
| General Specification | Dimensions | 215x130x85mm / 8.46x5.12x3.35in |
| Net Weight | 990g / 2.18lb | |
| Electromagnetic Compatibility | EN61000, EN55022, EN55024 | |
| Protection Level | IP21 | |
| Operating Temperature | -20°C ~ +55°C / -4°F ~ 131°F |
9. Warranty and Support
9.1 Warranty Terms
Thank you for choosing the HHJ series solar controller. Please carefully read this manual as it will help you maximize the many advantages the controller offers for your solar system. This manual provides important recommendations regarding installation and usage. For your own benefit, please read and pay close attention to the safety advice within.
In accordance with the instructions, repair services may be provided to users for any damaged units resulting from incorrect installation, disassembly, or improper use of this product.
- Within 30 days from the date of purchase, a malfunctioning controller will be replaced at no charge, provided that it has been used under normal circumstances and authorized by the company's technical personnel.
- Within 2 years from the date of purchase, a malfunctioning controller will be repaired at no charge.
NOTE: Unauthorized disassembly voids the warranty.
9.2 Warranty Exclusions (Declaration)
Under the following circumstances, our company reserves the right not to assume any quality warranty responsibilities:
- Damage caused by improper transportation.
- Damage resulting from incorrect storage, installation, or usage.
- Damage caused by non-professionals or untrained personnel installing and operating the equipment.
- Damage resulting from non-compliance with the instructions and safety warnings in this document.
- Damage caused by operation in environments that do not meet the requirements specified in this document.
- Damage due to operation beyond the parameter ranges specified in applicable technical specifications.
- Damage resulting from unauthorized disassembly, product alteration, or software code modification.
- Damage caused by abnormal natural conditions (force majeure), such as lightning, earthquakes, fires, storms, etc.
- Any damage resulting from failure to adhere to local standards and regulations during the installation and operation processes.
- Products outside the warranty period.
9.3 Contact Information
For further assistance or inquiries, please contact:
- Company: SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
- Tel/Fax: +86 755-28219903
- Email: support@powmr.com
- Web: www.powmr.com
- Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China
For a complete user manual, including detailed diagrams and advanced settings, please refer to the official PDF document: User manual (PDF).
10. User Tips
- Battery Compatibility: Always verify the compatibility of your battery type with the controller settings. If using a lead-acid battery, ensure it's either Vented, Sealed, or Gel, and configure the controller accordingly. For Lithium batteries, confirm the cell count (e.g., 4-cell, 8-cell, 15-cell, 16-cell) and set the D06 parameter correctly to optimize charging and prolong battery life.
- System Sizing: When connecting a battery, consider its capacity relative to the controller's capabilities. While the controller supports various battery voltages, ensure the battery's maximum charge current and voltage align with the controller's specifications to prevent damage.
- Parallel Expansion: If you plan to expand your solar system, the parallel operation feature allows for easy scalability. Remember to maintain the recommended 75mm spacing between units and configure the D05 parallel communication code for proper master-slave operation.