1. Introduction & Product Overview
This Feyree EV Charger is designed for electric vehicle AC charging, offering a simple yet highly functional solution. It supports various specifications including Type2, Type1, GB/T, and TS-NACS. The charger features both swipe card and plug-and-play charging methods, along with multiple safety protection functions. Its robust dustproof and waterproof design (IP66 rated) ensures safe operation in outdoor environments.
Key features include Dynamic Load Balancing (DLB) for efficient power distribution, remote control via a mobile application, a large LCD screen for real-time data, and high compatibility with various EV brands.
2. Safety Instructions
- Warning: The charging station must be grounded (PE) in order to use it properly.
- Warning: Do not place flammable, explosive, or combustible materials, chemicals, combustible vapors, or other hazardous materials near the charging station.
- Warning: Keep the charging plug head clean and dry. If dirty, wipe it with a clean and dry cloth. It is strictly forbidden to touch the charging plug core by hand when it is charged.
- Warning: It is strictly forbidden to use the charging station when the charging plug or charging cable is defective, cracked, worn, broken, or when the charging cable is exposed.
- Warning: Do not attempt to disassemble, repair, or modify the charging station. If repair or modification is needed, contact relevant staff. Improper operation may cause damage, water leakage, electrical leakage, short circuit, electric shock, and other risks.
- Warning: Use with caution during thunderstorms.
- Warning: Children should not approach or use the charging station during the charging process to avoid electric shock.
- Warning: Do not drive the car while it is charging. Charging can only start when the car is stationary. For hybrid cars, turn off the engine before charging.
- Warning: In case of emergency, press the emergency stop button immediately to cut off all input and output power.
- Warning: The use of the charging station is prohibited in the following cases and the manufacturer should be contacted immediately:
- Bad charging station shell.
- When the charging cable on the charging station is damaged, cracked, frayed, broken, etc.
- Lightning strikes charging station.
- Accidents or fires near charging stations.
- Water in the charging station.
- The length of the charging cable is not long enough to connect to the car, and an extension cable needs to be installed.
3. Setup
3.1 Pre-use Preparation
- Ensure that there are no open flames around the equipment and that the surrounding space is not blocked.
- Ensure that the equipment casing and charging cable are not damaged.
- Ensure proper maintenance of equipment.
- Make sure the emergency stop button is popped up. If it has been pressed, rotate the button clockwise to turn it back.
3.2 Physical Installation
The charging station is designed for wall mounting. Follow these steps for proper installation:
- Step 1: Mount the Bracket
According to the position of the holes on the metal back mounting bracket, use an electric drill to create holes in the corresponding positions on the wall. Refer to the diagram below for recommended installation height (e.g., 1100mm from the top of the charger to the ceiling, 1280mm from the top of the charger to the floor, 800mm from the bottom of the charger to the floor). Insert expansion tubes into the holes and use long screws to fix the metal mounting bracket to the wall.
Charger dimensions and mounting bracket installation. - Step 2: Hang the Charger
After fixing the metal bracket to the wall, hang the charger on the bracket. Use screws to secure the metal bracket underneath the charger to the wall. - Step 3: Install Charging Plug Holder
Install the charging plug holder in a convenient position near the charging station. - Step 4: Connect Power Supply
Connect the power supply to the charging station and ensure it can work properly. Refer to the wiring diagrams below for single-phase and three-phase connections.
3.3 Wiring Diagrams
Ensure correct wiring based on your charger's phase configuration:
Note on Type 2 Plugs:
- Type 2 Single Phase: L2 and L3 pins have no silver. Only supports single-phase charging.
- Type 2 Three Phase: L2 and L3 pins have silver. Supports both single-phase and three-phase charging.
3.4 App Installation and Connection (Tuya Smart / Smart Life)
The charger supports remote control via the Tuya Smart or Smart Life app (requires WiFi and Bluetooth function on the charger).
- Download the "Tuya Smart" or "Smart Life" App from your cell phone's app store.
- After downloading, open the app, turn on your phone's WiFi and Bluetooth.
- Select "Add Device" and follow the in-app instructions to complete adding your new device. This typically involves searching for nearby devices and entering your WiFi password.
Note: The app can also be used without WiFi. Connect your phone and charger by hotspot first, then you can control the charger via Bluetooth within 10 meters (requires your SIM card to have a signal).
4. Operating Instructions
4.1 Charging Steps
- Standby Status: When the charging station is in standby mode, the interface shows that the device is ready for charging. The indicator light (for Wi-Fi function only) is green and always on.
- Waiting for Card Swipe Status: After parking your car, take the charging plug from the holder, set the charging current (if not using app), then insert the charging plug into the electric vehicle's connector. Ensure the plug is securely inserted. The device will enter identity verification status.
- Start-up Device: Use an RFID card to authorize the use of the charging station.
- Start Charging: The device starts charging, and the interface displays charging status and information. The indicator light (for Wi-Fi function only) is green and breathing.
- Stop Charging:
- The charging station automatically stops charging when the vehicle is fully charged.
- In case of emergency, manually press the Emergency Stop button to cut off power.
- An RFID card can also be used to authorize stopping the charging process.
4.2 Key Operation Instructions (Control Box)
The control box features buttons for navigation and settings. Long press the designated area for 5 seconds to enter the setting interface.
- How to set the charging current: When the charging plug is not inserted, press button 'A' on the panel to adjust the charging current. After using the RFID card to turn on charging, the device will output the corresponding current. The current setting range is 8-32A for 7.6kW and 22kW versions, and 8-16A for the 11kW version.
- How to set delay time charging: When the charging plug is not inserted, touch the delay button on the panel to set the delayed charging time (0-15 hours). After swiping the card and turning on the charger, it will start charging after the set delay.
- How to set timing charging: Similar to delay charging, touch the timing button to set the charging duration (0-15 hours). The charger will stop after the set time.
- How to access the menu page: Long press the designated area on the panel for 5 seconds to enter the settings menu. For RFID-enabled versions, you may need to swipe the RFID card after the long press.
4.3 RFID Card Management
The charger supports RFID cards for starting and stopping charging. You can add or delete cards through the menu.
- Access the menu and navigate to "Rfid Manage".
- To add a card, select "Add Card" and swipe a blank RFID card.
- To delete a card, select "Delete Card" and follow the prompts to remove the binding of an existing RFID card. Up to 10 additional RFID cards can be added.
To turn on/off the RFID Cards function:
- Long press for 5 seconds to enter the settings page.
- Swipe an RFID card to enter.
- Navigate to "Setting" and then click to turn on/off the "CardID Check" function.
4.4 Dynamic Load Balancing (DLB) Function
The DLB function automatically adjusts charging power to prevent overloading your home's electrical system. It works by connecting an energy meter to your home circuit, which collects real-time current data. The charging equipment then adjusts its current based on this data and the rated current you set for your home circuit.
- Prerequisites:
- 485 communication must be correctly and reliably connected.
- The charging station and the energy meter must be on the same circuit as other household appliances.
- The total current set on the charging station should be less than or equal to the household total current.
- Setting Home Rated Current: Follow prompts for RFID swipe operation before modifying. Settable range is 20A to 99A.
5. Maintenance
- Regularly inspect the charging cable and plug for any signs of damage, cracks, or wear. If any damage is found, discontinue use immediately and contact support.
- Keep the charging station and its components clean and dry. Wipe with a soft, dry cloth. Avoid using harsh chemicals or abrasive materials.
- Ensure the area around the charging station is free from obstructions and flammable materials to allow for proper ventilation and safe operation.
- The charger is designed with high-strength materials and a unique waterproof and breathable membrane to dissipate heat faster and extend its lifespan. However, regular visual checks are recommended.
6. Troubleshooting
This section provides common troubleshooting steps for issues you might encounter. Refer to the Charging Status and Indicator Light section for specific light patterns.
| Fault Name | Reason for Failure | Recommendations |
|---|---|---|
| Over Voltage | AC input voltage is too high |
|
| Under Voltage | AC input voltage is too low |
|
| Over Current | AC input current is too high |
|
| Over TEMP | Charger internal temperature greater than 85°C |
|
| Elec Leakage | Leakage is greater than specified values (TypeA: AC30mA, TypeB: AC30mA+DC6mA) |
|
| Leakage self check | The sensor for detecting leakage is abnormal |
|
| PE Fault | Poor grounding or incorrect wiring |
|
| Err:CP | Charging plug CC/CP connection abnormality |
|
| Err:Reset | Reset button is pressed |
|
6.1 Charging Status and Indicator Light
| Charging Status | Green Light | Blue Light | Red Light | Description |
|---|---|---|---|---|
| Ready | Ever-bright | / | / | Power-up for self-test or reset |
| Connect | Flashing | / | / | Detection point 1 voltage is 9 ± 0.8 V. |
| Charging | / | Breathing | / | Detection point 1 voltage is 6 ± 0.8 V, relay closed |
| Finish | / | Ever-bright | / | Charging finished |
| Err:CP | / | / | Flash 1 time (0.5S) | Detection point 1 voltage is 9.8V<U<11.2V; 6.8V<U<8.2V; 12.8V<U or U<5.2V; relay opened |
| Under Voltage | / | / | Flash 2 time (0.5S) | Single-phase: voltage <85V, Three-phase: <304V |
| Over Voltage | / | / | Flash 3 time (0.5S) | Single-phase: voltage > 264V, Three-phase: > 457V |
| Elec Leakage | / | / | Flash 4 time (0.5S) | Relay is opened, it will be closed if re-powered after troubleshooting. |
| Over Current | / | / | Flash 5 time (0.5S) | The line current keeps at Ie+2<I <Ie+4 for 5 seconds, the relay is opened, then restarted automatically after 10 seconds. It will permanently disconnect after three repetitions. At I> Ie+4, the relay is disconnected and the charging is finished. |
| Over Temp | / | / | Flash 6 time (0.5S) | Temperature > 85°C, the relay is opened. When the temperature is < 65°C, charging restarts. |
| Err:Reset | / | / | Flash 7 time (0.5S) | Emergency stop button is pressed, the relay is opened, and it is allowed to close only after the fault is solved. |
7. Specifications
7.1 General Parameters
| Attribute | Value |
|---|---|
| Brand Name | feyree |
| Charger Type | Charging Station |
| Power | 7.6 KW / 11KW / 22KW |
| Current | 16A/32A |
| Voltage | 85V-264V (Single Phase) / 380V±20% (Three Phase) |
| Input Frequency | 50Hz-60Hz |
| Number of phases | single phase / three phase |
| Cable Length | 5m |
| IP Rating | IP66 (Charger Plug & Box) |
| Operating Temperature | -30°C ~ +55°C |
| Storage Temperature | -40°C ~ +80°C |
| Working Humidity | 5% ~ 95% non-condensation |
| Material | Copper alloy, silver plating (contacts) |
| Weight | 4.5kg |
| Dimensions (Length x Width x Height) | 46cm x 40cm x 10cm (Package) |
| Standby power consumption | < 3W |
| Cooling | Natural air cooling |
| Certificates | CE |
7.2 Control Box Functions
- Leakage protection (restart recover)
- Over voltage under-voltage protection (self-checking recover)
- Lightning protection
- Over current protection
- Overheat protection
- Ground protection
- Change the current: 8A/10A/13A/16A/20A/25A/32A adjustable
- RFID card function
- Charging time to make an appointment
- APP WIFI version
7.3 Product Performance
- Charging plug according to IEC 62196-2 standard.
- Control box in accordance with IEC61851 control principle.
- Insulation resistance: >1000MΩ.
- Terminal temperature rise: <50K.
- Mechanical life: Charging Plug plugging and unplugging times (Non-operating state) >10000 times.
- External impact: Charging Station Plug can withstand the 1-meter drop and 2 tons of vehicle crushing.
- Altitude: ≤2000m.
- With emergency stop function.
7.4 Package Contents
The product package typically includes:
- EV Charging Station
- Charging Cable (5m)
- RFID Cards (x3)
- Energy Meter
- Mounting Bracket
- Free Gift (e.g., charging plug holder)
8. User Tips
- Three-Phase to Single-Phase Connection: If you have a three-phase charger model but only a single-phase connection available, ensure your specific charger model supports single-phase operation. Some three-phase chargers are designed to work on a single phase, but it's crucial to verify this in the specifications or with an electrician to avoid damage or inefficient charging.
9. Warranty & Support
9.1 Customer Service Team
E-mail: tina@feyree.com
9.2 Two-Year Warranty
Feyree offers a two-year warranty to customers who purchase original Feyree products.
9.3 Lifetime Technical Support
In case of any product-related issues, we encourage you to reach out to us, providing pictures and videos for further assistance.
9.4 Exclusions
The warranty does not cover:
- Any product damage resulting from failure to follow the recommended guidelines.
- Damage caused by unauthorized disassembly of the machine or seeking maintenance from a non-designated service center.
- Purchased non-original Feyree products.
- Any modifications or do-it-yourself alterations carried out without guidance from a licensed electrician.
10. FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference; (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates and uses can radiate radio frequency energy, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Note: The Grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could void the user's authority to operate the equipment.
The device has been evaluated to meet general RF exposure requirement. To maintain compliance with FCC's RF exposure guidelines, the distance must be at least 20cm between the radiator and your body, and fully supported by the operating and installation configurations of the transmitter and its antennas.