Important Safety Instructions
WARNING: Carefully read and adhere to all safety instructions.
- Before installing and operating the controller, please read this user manual thoroughly and keep it for future reference.
- The installation or operation of the controller should only be performed by individuals who have received proper training and supervision.
- This controller product does not have user-serviceable components; do not disassemble or attempt to repair the controller yourself.
Controller Installation and Operation Safety
- Install the controller in a well-ventilated environment with adequate clearance around it.
- Install the controller on non-combustible walls and ensure there are no flammable materials nearby; it is normal for the controller to generate heat during operation.
- Place the controller in an environment that is protected from direct sunlight, rain, humidity, and dust, and keep it away from any flammable liquids or gases. The controller is for indoor use only.
- Do not install or operate the controller on top of, directly above, or in an enclosed space above batteries, as batteries emit explosive gases.
- Do not place any objects on top of the controller.
Battery Installation and Charging Safety
- Install and charge batteries in well-ventilated or exhaust-ventilated environments.
- Ensure there are no open flames in the vicinity of the batteries, as batteries emit explosive gases.
- Battery acid is corrosive; if battery acid comes into contact with the skin, rinse immediately with clean water.
- Do not charge non-rechargeable batteries. Do not charge lithium batteries when the temperature is below 0°C.
- Ensure that the equipment is properly configured for the type of battery connected to it.
DC Battery Connections Safety
- Ensure that the DC system is fully off/powered down by disconnecting all cables and/or new ports from the battery/DC system.
- Use flexible, multi-strand copper cables with an appropriate cross-sectional area, and connect them to matching fuses or circuit breakers.
- Connecting the photovoltaic array to the controller is prohibited until the battery is connected first.
Product Introduction
Welcome to the HHJ series solar controller. This controller represents advanced innovation in the field of solar technology and is designed to provide exceptional performance and reliability for your solar energy system. The controller is equipped with advanced CNC technology, an LCD display, automated operation, and a Maximum Power Point Tracking (MPPT) battery charging mode. Combined with advanced control technology, it significantly extends the lifespan of your batteries.
The HHJ series solar controller is designed to meet the diverse needs of various solar energy systems, whether in standalone systems or other application scenarios. It automatically controls the charging and discharging processes. By optimizing the controller's battery charging and discharging processes, it not only prolongs the battery's lifespan but also enhances the overall system's performance. The controller features self-diagnostic functions and electronic protection, effectively preventing damage to the controller or batteries during installation errors or system faults, ensuring system reliability and stability.
Our HHJ series solar controllers are suitable for a wide range of solar energy applications. We offer a user-friendly custom open-program configuration interface, making the configuration process of solar energy systems quicker and smoother. It also provides more possibilities for expanding solar energy systems. Whether you are setting up a small-scale residential standalone solar system or expanding your solar energy project, the HHJ series solar controller will be an indispensable partner.
By choosing the HHJ series solar controller, you will gain an efficient, sustainable, and secure energy management solution that provides strong support for future energy needs. We are committed to advancing solar technology and delivering outstanding products and services to you.
Features

Image: MPPT 60A Solar Controller features, including power ratings for 12V/24V/36V/48V systems, battery compatibility, dual cooling, and 99.9% tracking efficiency.
- Integrated Charging Presets: Adaptive charging logic for most battery types (flooded lead-acid, gel-sealed lead-acid, lithium batteries).
- Versatile Application: Compatible with 12V/24V/36V/48V system voltages.
- Multi-Stage Charging Algorithm: Optimizes each charging cycle, maintains battery capacity with preset charging parameters.
- Maximum Power Point Tracking (MPPT) Technology: Tracks Vmp of the array for maximum power collection, with 99.9% tracking efficiency and 97% peak conversion efficiency.
- Supports Up to 12 Units in Parallel: Easy expansion of solar panel configuration and energy storage capacity.
- Adaptive Boost Charging: Monitors battery response to determine boost stage duration, ensuring full charge and preventing overcharging.
- Durable and Secure: Includes protections against photovoltaic input overcurrent, photovoltaic array short circuit, reversed photovoltaic polarity, overvoltage, overdischarge, and over-temperature.
- External Temperature Probe Configuration: Precisely monitors battery temperature, stopping charging if it exceeds 65°C and resuming below 55°C.
- Forced Air Cooling: Built-in cooling fan for efficient heat dissipation.
- Lithium Battery Activation: Adjusts charging cycle for lithium batteries and activates protected lithium batteries using solar energy.

Image: Diagram illustrating multiple protection features: Overvoltage Protection for Batteries, Over-temperature Protection, Reversed PV Polarity Protection, Overdischarge Protection, and Short Circuit Protection.

Image: Illustration of the dual cooling system with a quiet bladeless fan and robust die-cast aluminum heat sink for efficient heat dissipation. Also shows applications in RVs, commercial vehicles, boats, yachts, and solar systems.
Product Appearance

Image: Front view of the PowMr MPPT Solar Controller HHJ-60A-PRO, highlighting the LCD display, control buttons, and connection ports.

Image: PowMr MPPT Solar Controller HHJ-60A-PRO with dimensions (8.46in height, 5.16in width, 3.35in depth) and key features like 60A MPPT, 12V/24V/36V/48V Auto, 160VDC Max PV Input, and Parallel Function.
| No. | Component | No. | Component |
|---|---|---|---|
| 1 | LCD display | 5 | Load port |
| 2 | Function key | 6 | Temperature probe port |
| 3 | PV input port | 7 | Parallel communication port |
| 4 | Battery port |
Setup (Installation and Wiring)
Unpacking and Inspection
Before unpacking, inspect the packaging for any signs of damage. After unpacking, check the contents to ensure nothing is damaged or missing. Inside the package, you will find the following items:
- Controller
- User Manual
- Installation screws
- Parallel connector
- External temperature sensor
Choosing the Installation Location
Before installation, several aspects should be considered to determine or provide a suitable and safe installation location:
- Install the controller in a space with good natural ventilation/exhaust.
- Avoid direct sunlight.
- Ensure there is ample clearance around the controller. The minimum clearance at the top, bottom, and both sides of the controller is 75mm.
- Install the controller on a non-combustible wall and ensure there are no flammable materials nearby; an increase in temperature during controller operation is a normal occurrence.
- Install the controller in an environment that avoids direct sunlight, rain, humidity, and dust, and keep it away from any flammable liquids or gases. The controller is for indoor use only.
- Do not install or operate the controller on top of, directly above, or in an enclosed space above batteries, as batteries emit explosive gases.
- When running multiple controllers in parallel, ensure they are installed at the same horizontal height, with a minimum spacing of 75mm between controllers.
Wiring Precautions
- Installation and wiring work should be carried out by a certified electrician.
- Wiring should follow the sequence of Battery > PV Input > Load.
- To avoid short-circuits and polarity reversal, pay attention to connecting the positive (+) cable to the device's positive (+) terminal and the negative (-) cable to the device's negative (-) terminal.
- Loose and/or incomplete connections can lead to cable or terminal overheating. Therefore, tighten all cables to minimize transition resistance, using cable sizes appropriate for the specific circuit's current rating.
- Do not connect the inverter to the load terminal of the controller, as doing so may result in irreversible damage to the equipment. If it is necessary to connect the inverter, please follow the battery connection steps outlined in Section 2.4, as indicated in the wiring diagram.
Installation and Wiring Guidelines
Please refer to the following steps to complete the installation and wiring of the controller. Alternatively, you can refer to the official user manual PDF for more details: PowMr HHJ-60A-PRO User Manual PDF.
Step 1. Mounting the Controller
Install the controller vertically with its ports facing downward, securing it to the wall through the four mounting holes using screws. For ease of installation, it is recommended to use two upper screws for initial "hanging" of the device, followed by the addition of two lower screws, and then fully tighten all four screws.
Step 2. Battery Wiring
Connect the battery to the controller using cables.

Image: Single Connection Diagram showing the wiring from PV array to controller, controller to battery, and controller to load. Note the fuse placement and inverter connection guidance.
Attention:
- Do not connect the inverter to the load terminal of the controller; otherwise, it may cause irreversible damage to the equipment. If it is necessary to connect the inverter, please refer to the diagram above.
- All wiring work must be carried out by professionals.
- For safe operation and proper application, circuit breakers of the appropriate specifications must be installed on the cables connected to the controller, and ensure that the connections are tight.
- Ensure that all circuit breakers are in the off position before completing all wiring.
- Connect the positive cable terminal to the positive terminal port, and the negative cable terminal to the negative terminal port.
- The above notes also apply to the PV ports and DC output ports.
Step 3. PV Wiring
Connect the photovoltaic array to the controller using cables. Ensure the PV array is connected after the battery.
Step 4. DC Output Wiring
Connect the load to the controller using cables.
Step 5. Temperature Probe Connection
Connect the temperature probe wire to the controller and securely fix the probe end to the battery using insulation tape.
WARNING: Risk of Electric Shock!
Before wiring, ensure that all power sources are turned off and follow the relevant inspection and operation procedures.
Step 6. Pre-Startup Check
Refer to the wiring diagram. If all connections are accurate, and all wiring is securely connected, close the circuit breakers in the order of Battery, PV Input, and Load terminals.
Operation Guide
Key Introduction
| Function key | Description |
|---|---|
| PRG/ESC | Enter the setup program / Exit the setup program |
| ▲ | Enter the next item/Increase value |
| ▼ | Return to the previous item/ Decrease value |
| ENTER | Confirmation button |
Main Page Overview
| Page | Description |
|---|---|
| 1 | PV Voltage / Output Power |
| 2 | Battery Voltage / Charging Current |
| 3 | Operating Mode / Temperature |
| 4 | Fault Codes/Parallel Operation Code |
Operating Modes
| Mode Codes | Description |
|---|---|
| 3.0 | Night Mode, No Charging |
| 4.0 | MPPT Mode |
| 7.0 | Boost Charging Mode (Constant Voltage Charging) |
| 8.0 | Float Charging Mode |
Overview of the Settings Page
On the main screen, press the PRG button to access the settings page. Use the ▲ and ▼ buttons to navigate through the settings items, then press the ENT button to enter the settings for the selected item. Within a setting item, use the ▲ or ▼ buttons to adjust the numerical values or toggle options. Finally, press the ENT button to save the settings. After configuring all the settings items, press the ESC button to exit the settings page.
Setting Guidelines
D00 Load Operation Mode Setting: Configure the mode and duration for enabling the load output.
- 1.00H: Light control mode (Loads start to supply power after dark and stop working after dawn).
- 2.24H (Default): Immediate load activation.
- 3.01H~23H: Adjust the duration for load activation.
D01 Float Charge Voltage Setting: After the boost charge phase, the controller will reduce the battery voltage by decreasing the charging current and maintain the battery at the float charge voltage setting value to keep the battery in a fully charged state. Adjust this setting based on the charging parameters of the connected batteries.
D02 Boost Charge Voltage Setting: During the boost charge phase, the battery will be charged at a constant preset voltage value. Set this value according to the specific charging parameters of your batteries.
D03 Low Voltage Disconnect Setting: When the battery voltage falls below this value, the controller will stop discharging the battery to prevent over-discharging.
D04 Voltage Calibration Setting: This setting allows you to calibrate the displayed battery voltage when there is a difference between the controller's detected voltage and the voltage measured with a multimeter. Note that using excessively long or thin cables can affect the controller's ability to accurately read the battery voltage.
D05 Parallel Communication Code Setting: This program requires no configuration if you are not operating in parallel mode. After completing the parallel wiring, use the D05 setting program to define the master and slave controllers. The controller with the lowest communication code value will be the master. If the master fails, the system will automatically select the controller with the next lowest code as the new master.
D06 Battery Type Setting: Select the appropriate battery type from the options (Lead-acid, Gel Sealed, Flooded, 4-Cell LiFePO4, 8-Cell LiFePO4, 15-Cell LiFePO4, 16-Cell LiFePO4, or User-Defined).

Image: Visual representation of compatible battery types (GEL, FLD, SLA, Li, USER) and a table detailing the sequence, display code, and corresponding battery type.
D07 System Voltage Setting: If D06 is set to USE (User-Defined), you will enter D07 to select the system voltage (12V/24V/36V/48V). If D06 is not set to USE, the system will automatically detect the system voltage.
Parallel Operation Guide
The controller device is capable of standalone operation for individual units and can also support a maximum of 12 units in parallel operation. When operating in parallel, communication between the parallel controllers is achieved through communication lines. The parallel controllers are installed at the same horizontal height.
Main Modules for Parallel Operation
- Controller: Each unit can operate independently or in parallel (up to 12 units).
- Solar Array: Each controller must be connected to a separate solar array. One solar array cannot be simultaneously connected to more than one controller. The input power connected to each controller should not exceed the rated input power of a single controller.
- Battery Bank: Parallel controllers are connected to the same battery bank.
Parallel Installation and Wiring

Image: Parallel Operation Schematic showing multiple solar arrays connected to individual controllers, which are then connected in parallel to a single battery pack via communication and power cables.
- Step 1. Install Parallel Devices: Install parallel devices at the same height level with a minimum distance of approximately 75mm between devices.
- Step 2. Connect Communication Lines: Connect the communication lines between the controllers.
- Step 3. Connect All Parallel Controllers to the Same Battery Bank: Connect all controllers to the battery bank in sequence.
- Step 4. Connect Each Controller to its Respective Photovoltaic Array: Individually connect each controller to its dedicated solar array.
- Step 5. Connect Each Controller to the DC Load: Finally, connect each controller to the DC load.
- Step 6. Set Parallel Operation Code: Set the parallel operation code for each controller, as detailed in the D05 setting guidelines in the Operation section.
Maintenance
We recommend conducting the following checks and maintenance at least twice a year to ensure optimal performance:
- Ensure the controller is securely mounted in a clean and dry environment.
- Ensure proper airflow around the controller and clean any dust or debris from the heat sinks.
- Inspect all exposed wires for insulation damage, such as severe sun exposure, friction wear, dryness, insect or rodent damage. Repair or replace any damaged wires as necessary.
- Tighten all terminals and check for loose, broken, or burnt cable connections.
- Confirm that all system components are properly grounded.
- Ensure all terminals are free from corrosion, insulation damage, high temperatures, or signs of burning/discoloration, and tighten terminal screws.
- Check for dirt, nesting insects, and corrosion. If present, clean promptly.
WARNING: Risk of electric shock!
Before performing the above operations, ensure that all power sources are turned off and then follow the relevant check and operation guidelines.
Troubleshooting
| Fault Code | Description | Resolution |
|---|---|---|
| 18 | Photovoltaic Input Voltage Too Low | Increase the photovoltaic array voltage by changing the series-parallel connection or adding more solar panels. |
| 60 | Over-temperature Protection | In case of over-temperature, the fan will start automatically to provide efficient forced cooling. |
| 63 | Battery Overvoltage | Charging will automatically stop, and it will resume when the battery voltage returns to normal levels. |
| 65 | Battery Undervoltage | Discharging will automatically stop, and it will resume when the battery voltage rises to normal levels. |
| 71 | Photovoltaic Input Voltage Too High | Reduce the photovoltaic array voltage by changing the series-parallel connection or reducing the number of solar panels. |
| 73 | Overcharging Current | Reduce the photovoltaic input power by decreasing the number of solar panels. |
Specifications
| Category | Parameter | Value (HHJ-60A-PRO) |
|---|---|---|
| Solar Input Power | Max. Input Power (12V System) | 720W |
| Max. Input Power (24V System) | 1440W | |
| Max. Input Power (36V System) | 2100W | |
| Max. Input Power (48V System) | 2800W | |
| Input Voltage Range | For 12V System | 20V~80V |
| For 24V System | 37V~105V | |
| For 36V System | 50V~160V | |
| For 48V System | 72V~160V | |
| Charging Technology | MPPT | |
| Charging Algorithm | 3 stages | |
| Battery Voltage Auto-Detection | 12V System | DC9V~DC15V |
| 24V System | DC18V~DC29V | |
| 36V System | DC30V~DC39V | |
| 48V System | DC40V~DC60V | |
| Overcharge Protection Voltage | 60V | |
| Charging Limit Current | 61A | |
| Maximum Efficiency | ≥98.1% | |
| Solar Utilization Rate | ≥99% | |
| Rated Output Current | 6A | |
| Maximum DC Output Current | 8A | |
| Temperature Protection | 75°C / 167°F | |
| Fan Start Temperature | >45°C / 104°F | |
| Fan Shutdown Temperature | <40°C / 95°F | |
| Dimensions | 215x130x85mm / 8.46x5.12x3.35in | |
| Net Weight | 990g / 2.18lb | |
| Electromagnetic Compatibility | EN61000, EN55022, EN55024 | |
| Protection Level | IP21 | |
| Operating Temperature | -20°C ~ +55°C / -4°F ~ 131°F | |
| Storage Temperature | -40°C ~ +75°C / -40°F ~ 167°F | |
Warranty and Support
Warranty Terms
- Within 30 days from the date of purchase, a malfunctioning controller will be replaced at no charge, provided that it has been used under normal circumstances and authorized by the company's technical personnel.
- Within 2 years from the date of purchase, a malfunctioning controller will be repaired at no charge.
NOTE: Unauthorized disassembly voids the warranty.
Warranty Exclusions (Declaration)
Our company reserves the right not to assume any quality warranty responsibilities under the following circumstances:
- Damage caused by improper transportation.
- Damage resulting from incorrect storage, installation, or usage.
- Damage caused by non-professionals or untrained personnel installing and operating the equipment.
- Damage resulting from non-compliance with the instructions and safety warnings in this document.
- Damage caused by operation in environments that do not meet the requirements specified in this document.
- Damage due to operation beyond the parameter ranges specified in applicable technical specifications.
- Damage resulting from unauthorized disassembly, product alteration, or software code modification.
- Damage caused by abnormal natural conditions (force majeure), such as lightning, earthquakes, fires, storms, etc.
- Any damage resulting from failure to adhere to local standards and regulations during the installation and operation processes.
- Products outside the warranty period.
Contact Information
SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
- Tel/Fax: +86 755-28219903
- Email: support@powmr.com
- Web: www.powmr.com
- Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China
User Tips
- Always double-check all wiring connections for tightness and correct polarity before powering on the system to ensure optimal performance and safety.
- Regularly inspect the controller and connections as part of your system maintenance to prevent potential issues.
Product Overview Video
Video: An overview of the PowMr HHJ-60A-PRO solar charge controller, detailing its components, MPPT charging efficiency, system voltage compatibility, three-stage charging, parallel operation capabilities, and multiple protection features.