ATORCH GR2P/W/WS

Contents

ATORCH GR2P/W/WS Din Rail Power Energy Meter User Manual

Models: GR2P (Basic), GR2PW (WiFi), GR2PWS (WiFi with Switch)

1. Introduction

This ATORCH Din Rail Power Energy Meter is designed for the measurement and control of various AC power parameters. It accurately measures voltage, current, power, electricity quantity (energy consumption), frequency, and electricity charges. Depending on the model, it also offers control and safety protection alarm functions, along with smart connectivity features.

It is suitable for single-phase AC power supplies with a voltage range of AC50~320V and a current range of 0-100A at 50/60Hz.

ATORCH Din Rail Power Energy Meter with display and app interface
ATORCH Din Rail Power Energy Meter displaying real-time data and a smartphone app interface.

2. Important Safety Warnings

WARNING: The input of this product involves strong electricity. To prevent electric shock, do not touch the metal parts with electricity during use. Always pay attention to safety during installation and operation.

  • Ensure all power is disconnected before installation or wiring.
  • Do not attempt to disassemble or modify the device.
  • This device should be installed by a qualified electrician.
  • Ensure proper grounding if required by local electrical codes.
  • Avoid using the device in environments with excessive moisture or extreme temperatures outside the specified operating range.

3. Package Contents

Upon opening the package, please verify that all items are present and in good condition:

  • ATORCH Din Rail Power Energy Meter (GR2P, GR2PW, or GR2PWS model)
  • User Manual (this document, or a printed version)
ATORCH Din Rail Power Energy Meter in its packaging
The ATORCH Din Rail Power Energy Meter and its retail packaging.

4. Specifications

Feature Specification
Product NameGuide Rail Meter Electricity Measure Smart Control Equipment
Product ModelGR2P, GR2PW, GR2PWS
Input VoltageAC50 ~ 320V (50/60Hz)
Maximum Current100A
Maximum Power32.0KW
Operating Temperature-10°C ~ +60°C
Accuracy Class1.0
Measuring Energy Range0 ~ 999999KWH
Display TypeAnalog and Digital (Color Screen)
Power SupplyAC
CertificationCE, RoHS
Dimensions45 x 36 x 80mm (Rail installation Size: 35mm)
Mobile Phone ControlTuya or Smart Life App (for WiFi versions)
Hardware UpgradeWiFi remote network firmware upgrade (for WiFi versions)
Power Off MemorySupported
Product label with detailed specifications
Detailed specifications as printed on the product label.

5. Installation and Wiring

The meter is designed for installation on a C45 National standard DIN Rail. Use a screwdriver to install and disassemble it by pressing down the external spring mounting buckle.

Always ensure the main power supply is OFF before attempting any wiring or installation.

Wiring diagram for ATORCH Din Rail Power Energy Meter
Wiring Diagram: Connect the AC input (L-IN, N-IN) and AC output (L-OUT, N-OUT) as shown. The meter is installed on a DIN rail.

Wiring Steps:

  1. Mount the meter onto a standard 35mm DIN rail.
  2. Connect the Live (L-IN) and Neutral (N-IN) wires from your AC power source to the corresponding input terminals on the meter.
  3. Connect the Live (L-OUT) and Neutral (N-OUT) wires to your load (the device or circuit you wish to monitor/control).
  4. Ensure all connections are secure and properly insulated.
  5. Once wiring is complete, you may restore power to the circuit.
ATORCH Din Rail Power Energy Meter installed in an electrical panel
Example of the ATORCH meter installed alongside other circuit breakers in an electrical panel.

6. Operation

6.1 Main Interface Description

The meter's color screen displays various parameters simultaneously. The layout includes:

  • Vol: Voltage (V)
  • Cur: Current (A)
  • Pwr: Power (W)
  • Ene: Accumulated Energy (KWh)
  • Bill: Electricity Bill (based on set price)
  • Fre: Frequency (Hz)
  • Factor: Power Factor (PF)
  • Run Time: Device operating time
  • CPU Temp: Internal CPU temperature
  • Power/Connect Buttons: For navigation and connection.
Basic Version (GR2P) display showing voltage, current, power, energy, bill, frequency, power factor, run time, and CPU temperature
Main display interface of the Basic Version (GR2P) meter.

6.2 Button Operation

The meter features two main buttons, typically labeled '-' (minus) and '+' (plus), and a central 'M' (Menu) button for navigation and settings.

Diagram showing button functions and display indicators
Main interface description and button operation method.
  • '-' Button:
    • Short press: Page up through display screens.
    • Long press: Switch display mode.
    • When a number is flashing (in settings): Continuously reduce the value.
  • '+' Button:
    • Short press: Page down through display screens.
    • Long press: Switch display mode.
    • When a number is flashing (in settings): Continuously add the value.
  • 'M' (Menu) Button:
    • Short press: Flash the set number / repeatedly short press to switch number position (in settings).
    • Long press: Enter the background setting menu.

6.3 System Settings

To access system settings, long press the 'M' button. Use short presses of 'M' to navigate through the setting columns. When a number is flashing, use the '+/-' buttons to adjust the value. Long press '+/-' to confirm or abort the flashing number.

Key settings include:

  1. Display Brightness: Adjust screen brightness (e.g., 9).
  2. Standby Brightness: Adjust brightness in standby mode (e.g., 3).
  3. Enter Standby Time: Set the duration before entering standby (e.g., 60S).
  4. Key Beep: Turn button beep sound ON/OFF.
  5. Price Setting: Set the electricity price (e.g., 0001.00).
  6. Over-Voltage Threshold: Set the maximum allowable voltage (e.g., 265.0V).
  7. Over-Current Threshold: Set the maximum allowable current (e.g., 100.0A).
  8. Over-Power Threshold: Set the maximum allowable power (e.g., 26500W).
  9. Under-Voltage Threshold: Set the minimum allowable voltage (e.g., 075.0V).
  10. Switching Model: Controlled (for GR2PWS model).
  11. Standby Screen: Choose between simple measurement or detailed display.
  12. Wi-Fi Device Reset: Reset WiFi settings (for WiFi versions).
  13. Date Zero: Clear accumulated data.
  14. System All Default Setting: Restore factory settings.

Notes on Settings:

  • Protection Thresholds: If over-voltage, over-current, or under-voltage thresholds are reached, an alarm will display. For relay-equipped models (GR2PWS), power output will be cut off.
  • Clear Accumulated Data: Navigate to 'Date Zero' and press the '+' button. An 'OK' prompt will appear to confirm clearing accumulated electricity bill data.
  • WiFi Settings Reset: If your WiFi network password changes, reset this setting to reconfigure the network.
  • Restore Factory Settings: Navigate to 'System All Default Setting', short press 'M', then long press '+' for 3 seconds to reset.

6.4 Alarm Function

The meter provides alarm functions based on the model:

  • Basic version (GR2P): Only provides prompt alarms; does not cut off power. WiFi is not supported.
  • WiFi version (GR2PW): Only provides prompt alarms; does not cut off power. Supports WiFi settings and reminders.
  • WiFi Switch Version (GR2PWS): Supports WiFi, provides prompt alarms, and can cut off power.

Note: For GR2PWS, insufficient power may prevent the cut-off function from working. This function requires the WiFi version app operation. GR2P and GR2PW versions do not have this function.

Dual alarm prompts for over voltage, over current, over power, and low voltage
Visual representation of dual alarm prompts for various electrical anomalies.

7. Connectivity (Bluetooth & WiFi)

7.1 Bluetooth Connection (for GR2P-BLE models)

For Bluetooth versions, you can connect to a smartphone app or PC software:

  1. Search for "E_test" in the Apple App Store or scan the Android QR code to download the app.
  2. Open the app and click the Bluetooth icon (usually in the upper left corner) to enter the device list.
  3. Select the
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.