1. Product Overview
This document provides instructions for the installation, operation, and maintenance of the Hongxin 5-18V 6mm Hose Barb End Water Flow Sensor. This sensor is designed for precise flow measurement in various applications, including coffee machines, hot water purifiers, water dispensers, and other water-based systems.

Figure 1: Front view of the water flow sensor.

Figure 2: Side view of the water flow sensor, highlighting the electrical connection pins.
Video 1: Product demonstration of the water flow sensor.
2. Setup and Installation
2.1 Physical Installation
- Hose Connection: The sensor features 6mm hose barb ends for easy connection to compatible tubing. The intubation design of the inlet and outlet pipes facilitates straightforward connection and operation.
- Orientation: For optimal accuracy, the flow meter should be installed horizontally.
- Filtration: To prevent particle debris from affecting sensor performance and accuracy, the sensor must be installed after a suitable filter in the water line.
- Environment: Avoid installing the flow sensor in environments with strong vibration or shaking, as this can negatively impact measurement accuracy.
- Mounting: The sensor is small and lightweight, designed for self-assembly in four directions, making it easy to install in various configurations.

Figure 3: Diagram illustrating the recommended horizontal installation for accurate flow measurement.
2.2 Electrical Connection
The sensor uses an NPN transistor open collector for signal output. Ensure proper wiring according to the circuit diagrams provided below. Cables are not included with the sensor.

Figure 4: Various wiring diagrams for the flow sensor, including simple, TTL level, and optocoupler isolation circuits.
2.3 Dimensional Information

Figure 5: Detailed dimensional drawing of the water flow sensor (all units in millimeters).
3. Operating Instructions
The water flow sensor generates a square wave pulse output proportional to the water flow rate. This signal can be used by a microcontroller or other electronic circuits to calculate the volume of water passing through the sensor.
- Output Signal: Square wave with approximately 50% duty cycle.
- Flow Rate Calculation: The frequency (F) of the output pulses can be converted to flow rate (Q) using the formula:
F(Hz) = 76 * Q (l/min). - Power Supply: Ensure the sensor is powered within the specified voltage range of +3.8V to +20V DC.
4. Maintenance
- Filtration: Regularly check and clean the filter installed upstream of the sensor to prevent debris accumulation, which can affect accuracy and sensor lifespan.
- Cleaning: If the sensor's internal components become fouled, carefully disassemble (refer to Figure 6 for internal view) and clean with appropriate methods, ensuring no damage to the rotor or magnetic components.
- Inspection: Periodically inspect hose connections for leaks or damage.

Figure 6: Internal view of the sensor, showing the rotor assembly.
5. Troubleshooting
- Inaccurate Readings:
- Check for debris in the water line or sensor. Ensure a filter is in place and clean.
- Verify the sensor is installed horizontally.
- Ensure there are no strong magnetic materials close to the sensor, as this can alter its characteristics and affect readings.
- Check for excessive vibration or shaking in the installation environment.
- No Output Signal:
- Verify power supply voltage is within the +3.8V to +20V DC range.
- Check all electrical connections for proper wiring and secure contact.
- Ensure water is actually flowing through the sensor.
6. Specifications
| Feature | Specification |
|---|---|
| Product Name | Flow Meter |
| Model | 40JE1AA800761 |
| Manufacturer | Shenzhen Hongxin Hardware Co., Ltd |
| Calculation Formula | F(Hz) = 76 * Q (l/min) |
| Flow Range | 75ml - 570ml/min |
| Measurement Accuracy | +/- 3.0% |
| Temperature Range | -10°C to 65°C |
| Pressure Range | -10 to 0.3 Bar at 20°C |
| Power Supply Voltage | +3.8V to +20V DC |
| Signal Connection | NPN Transistor Open Collector |
| Signal Voltage | VDC GND |
| Connection Terminal | PANCON MAX-CON 156MLSS |
| Output Signal | Square Wave |
| Duty Cycle | ~50% |
| Rated Voltage & Current | DC5V, no more than 8mA |
| Output Voltage (DC 5V) | High level ≥ 4.5V; Low level ≤ 0.5V |
| Pulse Output Duty Cycle | 50% ± 10% |
| Insulation Resistance | ≥ 100M Ohm |
| Tightness | No leakage/deformation after 0.8MPa water for 1 min |
| Working Pressure | ≤ 0.8Mpa |
| Electrical Strength | AC500V 50Hz |
| Material | Food Grade POM (Polyformaldehyde) |
| Dimensions | 56 x 50 x 35mm (2.2 x 1.97 x 1.38 inches) |
| Color | Black |
| Quantity | 1 Pc |
7. User Tips
- Users have reported stable and accurate readings at flow rates between 150-200 milliliters per minute.
- Ensure all connections are secure to prevent leaks, especially when integrating into existing systems.
- Remember that connecting cables are not included with the sensor and must be sourced separately.
8. Warranty and Support
For technical support, warranty inquiries, or further assistance, please contact the manufacturer or your seller. When contacting support, please provide your product model number (40JE1AA800761) and a detailed description of the issue.
Manufacturer Contact:
Shenzhen Hongxin Hardware Co., Ltd
E-mail: smthxwj@163.com
Tel: +86 13534226519