1. Introduction
The PowMr MPPT Solar Charge Controller is an advanced maximum power point tracking (MPPT) device designed to efficiently manage power flow from your solar panels to your battery bank. This series includes models with current ratings of 20A, 30A, 40A, and 60A, supporting 12V, 24V, 36V, and 48V battery systems automatically. It is suitable for various battery types including Vented, Sealed, Gel, NiCd, Lead Acid, and Lithium batteries.
Key features include a 3-stage charging algorithm to optimize battery performance and extend battery life, multi-function protection, and high PV utilization (≥99%). The controller is equipped with a backlight LCD for easy monitoring and configuration.
Image: PowMr MPPT Solar Charge Controller models, showing 20A, 30A, 40A, and 60A variants.
2. Safety Precautions
- This series of MPPT controllers uses a common positive design. The positive pole of the PV array, battery, and load can be grounded simultaneously.
- If an inverter or other high starting current device is part of your system, connect it directly to the battery. Do not connect it to the controller's load terminal.
- For lithium batteries, it is crucial to set the system voltage and the correct battery type before use. Refer to section 3.8 and 3.9 for detailed instructions.
- Critical Connection Order: Always connect the battery first, then the solar panel, and finally the load. Failure to follow this order can damage the battery.
3. Setup and Installation
Follow these steps to correctly connect and install your solar charge controller:
- Step 1: Connect Batteries - Connect the battery to the controller. Ensure correct polarity.
- Step 2: Connect the Load - Connect your DC load to the controller's load terminals. Ensure correct polarity.
- Step 3: Connect the Solar Panels - Connect the PV array to the controller's solar panel terminals. Ensure correct polarity.
- Step 4: Connect Inverter (Optional) - If using an inverter, connect it directly to the battery terminals. This step can be ignored if no inverter is used.
Wiring Diagram:
Image: Diagram illustrating the connection sequence for the solar charge controller, PV array, battery, and DC load. It also shows an optional inverter connection to the battery.
For a visual guide on unboxing and basic setup, please watch the official product video:
Video: An overview of the PowMr Keeper series solar charge controllers, including unboxing, showing the included user manual and installation guide, and highlighting key features like MPPT efficiency, charging current, 3-stage charging, maximum PV input voltage, system voltage compatibility (12V/24V for lithium-ion and lead-acid), and DC output capabilities.
4. Operating Instructions
4.1 LCD Screen Overview
The LCD screen displays various system parameters and statuses. Key indicators include PV array status, battery status, load status, voltage, current, temperature, and battery type.
Image: A detailed view of the 60A model's LCD screen, showing battery voltage, charging current, temperature, and working mode. It also highlights the fan cooling system.
| Item | Icon | Status |
|---|---|---|
| PV array | ☀️ / 🌙 | Day / Night |
| PV array | MPPT icon | Charging |
| Battery | Battery icon | Uncharged / Battery capacity |
| Battery | LiPo / LiFe | Battery type |
| Load | Light bulb icon | Load on / Load off |
4.2 Button Definitions
| Button Meaning | Button Pattern | Button Function |
|---|---|---|
| MENU | ▲ | Short Press: Switch down/next interface. Hold for 3 seconds: Enter next interface. |
| SET | SET | Short Press: Switch up. Hold for 3 seconds: Exit without saving. |
NOTICE: From the first interface, long press the "MENU" button for 3 seconds to enter the secondary interface. It will automatically switch back to the first interface if no action is taken for 15 seconds.
4.3 Boot Screen
When the system is powered on, the LCD will first detect and display the starting interface, followed by the battery voltage interface, and then the software revision.
4.4 Load Switch On/Off
From the main page, a short press of the "SET" button will toggle the load on or off. This function is available in any load operating mode.
4.5 Main Loop Pages
After powering on, the controller defaults to the main page. Use short presses of "MENU" or "SET" to navigate through the main loop pages, which display information such as battery temperature, charging current, discharging current, and accumulated charging/discharging Amp-hours.
4.6 Setting Pages
From the main page, long press "MENU" for 3 seconds to enter the setting pages. Short press "MENU" or "SET" to switch between different setting parameters. To save changes, long press "MENU" for 3 seconds. To exit without saving, long press "SET" for 3 seconds.
4.7 Battery Type and System Voltage Setting
It is critical to configure the correct battery type and system voltage for optimal performance and battery longevity.
- Battery Type: Navigate to the battery type page (User Mode 1) in the setting menu. Long press "MENU" for 3 seconds to enter the selection. Use "MENU" or "SET" to choose between GEL, Sealed, Flooded, and Lithium battery types.
- Lithium Battery Capacity: For lithium batteries, after selecting the type, long press "MENU" for 3 seconds to enter capacity setting. The parameter will flash. Use "MENU" or "SET" to adjust the capacity. Long press "MENU" for 3 seconds to save.
- System Voltage: After setting the battery type, proceed to the system voltage page. Long press "MENU" for 3 seconds until "AUTO" flashes. Then, short press "MENU" or "SET" to select 12V or 24V.
Battery Type Options:
| Display | Battery Type |
|---|---|
| USE 1 | Lead-acid battery custom |
| GEL | Colloidal lead acid battery |
| SLD | Sealed lead acid battery |
| FLD | Valve-Regulated Lead-Acid Battery |
| 4*3.2 | 4S LiFePO4 battery |
| 5*3.2 | 5S LiFePO4 battery |
| 3*3.7 | 3S Lithium-ion battery |
| 4*3.7 | 4S Lithium-ion battery |
| USE 2 | Lithium battery custom |
4.8 Load Working Mode
The controller offers four load working modes to configure load output conditions and durations:
| Icon | Description |
|---|---|
| LD1 | Regular mode: The load works normally and can be turned on or off manually. |
| LD2 | Light control mode: The load automatically turns on at dark and turns off at dawn. |
| LD3 | Light & time control mode: Load working hours after dark, load working hours before dawn. (Automatically identifies dark and light according to local environment) |
| LD4 | Reverse light control mode: Load automatically turns on at dawn, load automatically turns off at dark. |
In light control modes (LD2, LD3, LD4), the controller will start or stop the load with approximately a 30-second delay after light detection or disappearance. The load on/off button on the main page is functional in any load operating mode.
4.9 PV Voltage Page
Long press "SET" for 3 seconds to switch between the main page and the PV voltage display page.
4.10 Charging Duration Settings
To adjust equalization or absorption charging durations, navigate to the respective charging page from the main menu. Long press "MENU" for 3 seconds until the parameter flashes. Continue pressing "MENU" for 3 seconds to enter the duration setting page. Use short presses of "MENU" or "SET" to increase or decrease the time. Long press "MENU" to save.
5. Maintenance
To ensure optimal performance and longevity of your PowMr MPPT Solar Charge Controller, consider the following general maintenance tips:
- Keep the controller in a clean, dry, and well-ventilated area to prevent overheating.
- Regularly check all wiring connections for tightness and corrosion. Loose connections can lead to power loss or damage.
- Inspect the controller for any visible signs of damage or wear.
- Ensure the cooling fan (if present on your model) is free from dust and obstructions to maintain efficient heat dissipation.
- Periodically verify that the battery type and system voltage settings are correct, especially after any system modifications or battery replacements.
6. Troubleshooting
The controller displays error codes to help identify and resolve issues. The fault code consists of an "E" and two digits. The first digit represents the current error count, and the second digit indicates the specific fault condition.
| Error Code | Cause | Correction |
|---|---|---|
| PV array indicator is off (sunlight enough) | Solar panel is disconnected. | Check if PV array connection is proper. |
| No sign on LCD (connection right) |
|
|
| E 1 (Ex1) | Battery over discharge. | Load will stop automatically and recover when battery voltage reaches 12.6V (LVR). |
| E 2 (Ex2) | Battery over voltage. | Ensure settled high voltage disconnection voltage is over battery voltage and reconnect PV array. |
| E 3 (Ex3) | Over load. | Reduce load or check load connection. |
| E 5 (Ex5) | Controller overheating. | The controller will restart after it cools down. |
| E 6 (Ex6) | Input voltage of solar panel is too high. | Check voltage of solar panel and reduce quantities of solar panel in series. |
| E 7 (Ex7) | No operation. | Controller will restart after setting system voltage. |
7. Technical Data
| Parameter | 20A Model | 30A Model | 40A Model |
|---|---|---|---|
| Rated Charge Current | 20A | 30A | 40A |
| PV Input | |||
| Max. open voltage of PV array | <60V | <75V | <100V |
| System rated voltage | 12/24V Auto recognized | ||
| Battery voltage range | 8V~32V | ||
| Maximum input power | 260W(12V) / 520W(24V) | 390W(12V) / 780W(24V) | 520W(12V) / 1040W(24V) |
| DC Output | |||
| Rated Discharge Current | 20A | 20A | 30A |
| Battery type | User default, Sealed, Flooded, GEL, LiFePO4, Li(NiCoMn)O2 | ||
| Equalize charging voltage* | Maintenance-free lead-acid battery: 14.6V; GEL: 14.2V; Lead-acid Flooded battery: 14.6V. Duration: 2 hours. | ||
| Absorption charging voltage* | Maintenance-free lead-acid battery: 14.4V; GEL: No; Lead-acid Flooded battery: 14.8V. Duration: 2 hours. | ||
| Float charging voltage* | Maintenance-free lead-acid battery, GEL, Lead-acid Flooded battery: 13.8V. | ||
| LVR* | Maintenance-free lead-acid battery, GEL, Lead-acid Flooded battery: 12.6V. | ||
| LVD* | Maintenance-free lead-acid battery, GEL, Lead-acid Flooded battery: 10.8V. | ||
| Static loss | ≤50mA | ||
| HVD | Lead acid battery 16V | ||
| Light control voltage | 5V/10A | ||
| Temperature compensation coefficient | -4mV/°C/2V(25°C) | ||
| Discharge loop voltage drop | ≤0.2V | ||
| LCD temperature | -20°C~+70°C | ||
| Operating temperature | -20°C~+55°C | ||
| Storage temperature | -30°C~+80°C | ||
| Working humidity | ≤90%, No condensation | ||
| Protection class | IP30 | ||
| Grounded type | Positive grounded | ||
| Aperture for installation | Φ5mm | ||
*Above parameters are for 12V system at 25°C; values are twice for 24V system.
8. User Tips
- Prioritize Battery Settings: When using lithium batteries, always set the system voltage and the correct battery type first before any other operations. This is crucial for proper charging and to prevent damage.
- Correct Wiring Sequence: To avoid damaging the battery or controller, always connect the battery first, then the solar panel, and finally the load.
- Inverter Connection: If you are using an inverter, connect it directly to the battery, not to the controller's load terminals, especially for devices with high starting currents.
9. Warranty and Support
For technical support or inquiries, please contact:
- Company: SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
- Tel/Fax: +86 755-28219903
- Email: support@powmr.com
- Web: www.powmr.com
- Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China
A detailed user manual in PDF format is also available for download. Please refer to the official website or contact support for the latest version: PowMr MPPT Solar Charge Controller User Manual (PDF)