SUSWE SU600 Series Variable Frequency Drive (VFD) User Manual

Economical VFD Variable Frequency Drive Converter Inverter for Motor Speed Control

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the SUSWE SU600 Series Variable Frequency Drive (VFD). The SU600 series is designed to convert 220V to 380V or 220V to 220V, or 380V to 380V power for precise motor speed control, offering a range of power outputs from 0.75KW to 7.5KW. Please read this manual thoroughly before using the product.

SUSWE SU600 VFD with power and voltage specifications

Figure 1: SUSWE SU600 VFD with Power (0.75-5.5kW) and Voltage (220V/380V) Specifications

2. Safety Information

Always observe the following safety precautions to prevent personal injury or damage to the equipment:

  • Ensure all power is disconnected before installation, wiring, or maintenance.
  • Only qualified personnel should install, operate, and maintain this equipment.
  • Verify correct voltage and current ratings before connecting to power.
  • Proper grounding is essential to prevent electric shock.
  • Do not touch internal components immediately after power-off, as residual voltage may be present. Wait at least 5 minutes.
  • Protect the VFD from moisture, dust, and corrosive environments.
  • Ensure adequate ventilation to prevent overheating.

3. Product Overview

3.1 Key Features

  • Economical variable frequency drive for motor speed control.
  • Supports various power ratings: 0.75KW, 1.5KW, 2.2KW, 3.7KW, 4KW, 5.5KW, 7.5KW.
  • Input voltage options: 220V or 380V.
  • Output type: Single-phase or Three-phase.
  • Main board material characteristics: Waterproof, Moisture-proof, Mildew-proof for enhanced durability.
  • User-friendly control panel with clear indicators.
  • External operation panel support for flexible control.
  • CE certified.
Internal components of the SUSWE VFD showing waterproof, moisture-proof, and mildew-proof main board

Figure 2: Inverter Components Display with Main Board Characteristics

3.2 Control Panel and Indicators

The VFD features an intuitive control panel for easy operation and monitoring:

VFD control panel with labeled buttons and indicators

Figure 3: Introduction to Operation and Display Interface (Humanity Design VFD)

  • Programming Key (PRG): Enters/exits programming mode.
  • Confirm Key (ENT): Confirms parameter settings.
  • Run Key (RUN): Starts motor operation.
  • Stop Key (STOP/RST): Stops motor operation and resets faults.
  • Incremental Key (▲): Increases parameter values or navigates up.
  • Decrement Key (▼): Decreases parameter values or navigates down.
  • Knob: For fine-tuning frequency or parameter values.
  • External Network Port: For external communication.
  • Indicators: FWD (Forward), REV (Reverse), Hz (Frequency), A (Current), V (Voltage), ALM (Alarm/Fault).

4. Specifications

The SUSWE SU600 series VFD comes in various models with different power ratings and input/output configurations. Below are general specifications and a detailed series index.

Product parameters for SU600-0R75G1 model

Figure 4: Example Product Parameters (SU600-0R75G1)

General Specifications
Attribute Value
Brand Name Erilles
Model Series SU600
Type DC/AC Inverters
Output Current 2.5-13A (varies by model)
Output Frequency 50/60Hz
Output Power 0.75KW - 7.5KW (varies by model)
Output Type Single/Three-phase
Weight 750g - 1150g (approx., varies by model)
Dimensions (approx.) 15*15*10 cm (varies by model, e.g., 185x87x138mm for 3.7kW/5.5kW)
Certification CE
Customization Yes

4.1 SU-600 Frequency Converter Series Index

Table of SU-600 frequency converter series index with power, current, and adapted motor details

Figure 5: SU-600 Frequency Converter Series Index

Refer to Figure 5 for detailed specifications including power supply capacity, rated input current, rated output current, and adapted motor power (kW/HP) for different voltage configurations (Single-phase 220V into three-phase 380V/220V, and Three-phase 380V into three-phase 380V).

5. Setup

5.1 Wiring Diagram

Follow the wiring diagram carefully for proper and safe installation. Ensure all connections are secure and correctly matched to their respective terminals.

Wiring diagram for input power, output motor, ground, and brake resistor connections

Figure 6: Basic Wiring Diagram

  • Input Power Connection: Connect R, S/L1, T/L2 terminals to your power source.
  • Output Power Connection: Connect motor U, V, W terminals to your three-phase induction motor.
  • Ground Wire: Connect the ground wire to the designated ground terminal.
  • Brake Resistor Connection: For CNC machine tool selection, connect the brake resistor to P+ and PB terminals.
Detailed terminal wiring diagram including multifunctional inputs, analog I/O, and RS485

Figure 7: Detailed Terminal Wiring Diagram

Figure 7 provides a comprehensive view of all terminals:

  • Multifunctional Input Terminals: X1, X2, X3, X4, COM for various control signals.
  • External Keyboard Interface: J11 for connecting an external operation panel.
  • Analog Input (AI): DC 0-10V / DC 0-20mA with +10V and GND.
  • Analog Output (AO): DC 0-10V / 0-20mA.
  • RS485 Communication: 485+, 485- for serial communication.
  • Relay Output: TA, TC for external control.
  • Potentiometer: SK-10K for speed adjustment.

5.2 External Operation Panel

The VFD supports an external operation panel for remote control and monitoring. Connect the external panel to the designated port using a network cable.

Connection of external operation panel to the VFD

Figure 8: External Operation Panel Connection

6. Operating Instructions

After successful installation and wiring, you can begin operating the VFD using the control panel or an external panel.

6.1 Basic Operation

  1. Power On: Ensure all connections are correct and secure, then apply power to the VFD. The display should light up.
  2. Parameter Setting: Press the PRG key to enter programming mode. Use the ▲ and ▼ keys to navigate through parameters. Use the ENT key to select a parameter and confirm changes. The knob can be used for precise adjustments.
  3. Start Motor: Press the RUN key to start the motor. The display will show the operating frequency.
  4. Adjust Speed: Use the knob or the ▲ and ▼ keys to adjust the motor speed (frequency).
  5. Stop Motor: Press the STOP/RST key to stop the motor.
  6. Fault Reset: If a fault occurs (indicated by the ALM light), address the issue and then press the STOP/RST key to reset the fault.

6.2 Product Demonstration Video

For a visual guide on the product's features and operation, please watch the official demonstration video:

Video 1: SUSWE VFD Product Demonstration

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your VFD.

  • Cleaning: Keep the VFD clean and free from dust. Use a soft, dry cloth for cleaning. Do not use liquid cleaners.
  • Ventilation: Ensure that the cooling fan and ventilation openings are not obstructed. Periodically check and clean the fan to maintain proper airflow.
  • Connections: Periodically check all wiring connections for tightness and signs of corrosion.
  • Environment: Operate the VFD within its specified environmental conditions (temperature, humidity). The main board is designed to be waterproof, moisture-proof, and mildew-proof, contributing to its durability in various industrial settings.
  • Inspection: Visually inspect the VFD for any signs of damage, discoloration, or unusual odors.

8. Troubleshooting

If you encounter issues with your VFD, refer to the following general troubleshooting steps. For specific fault codes and advanced diagnostics, please consult the comprehensive product manual (if available) or contact customer support.

  • No Power/Display: Check the input power supply and all power connections. Ensure the circuit breaker is on.
  • Motor Not Running: Verify that the RUN command is active. Check motor wiring and parameters. Ensure no fault indicators are active.
  • Overcurrent/Overload: Check the motor load. Ensure motor parameters are correctly set in the VFD. Inspect motor and load for mechanical issues.
  • Overvoltage/Undervoltage: Check the input power supply voltage. Ensure the VFD is rated for the supply voltage.
  • Overheating: Check ambient temperature, ensure proper ventilation, and clean cooling fins/fan.
  • Fault Indication (ALM): Note the specific fault code displayed (if any) and refer to the detailed manual for its meaning and resolution.

9. User Tips

  • Versatile Application: The SU600 series is suitable for a wide range of motor applications, including those requiring 3-phase output, such as heat pumps. Its high output power and customizable features make it adaptable to various industrial needs.
  • Parameter Adjustment: Take time to understand the programming parameters. Correct parameter settings are crucial for optimal performance and motor protection.
  • External Control: Utilize the external operation panel or multifunctional input terminals for integrated control within your system, enhancing flexibility and convenience.

10. Warranty and Support

For any questions, technical assistance, or warranty claims, please contact the seller or manufacturer directly. Provide your product model and purchase details for efficient support.

We are committed to providing high-quality products and support. If you have any concerns or require further assistance, please reach out to our customer service staff.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.