1. Introduction
The Hi-Link 2W Ultra Small Series AC-DC Power Module is a compact, high-efficiency power supply designed by Shenzhen Hi-Link Electronic Co., Ltd. These modules offer a global input voltage range, low temperature rise, low power consumption, high efficiency, high reliability, and high safety isolation. They are widely used in various applications including smart home devices, automation control systems, communications equipment, and instrumentation.

2. Product Features
- Ultra-thin, ultra-small, smallest volume design.
- Global universal input voltage (90~245Vac).
- Low power consumption, green environmental protection, no-load loss less than 0.1W.
- Low ripple, low noise output.
- High output short circuit and over-current protection with self-recovery function.
- High efficiency, high power density.
- Input and output isolation voltage of 3000Vac.
- 100% full load aging and testing performed.
- High reliability, long life design, with continuous working time greater than 100,000 hours.
- Meets UL, CE requirements; product design adheres to EMC and safety testing standards.
- Utilizes high-quality environmentally friendly waterproof plastic potting, providing moisture, vibration, water, and dust resistance to meet IP65 standards.
- Economic and cost-effective solution.
- Operates without the need for external circuitry.
- 1-year quality guarantee period.
3. Technical Specifications
3.1. General Specifications
| Attribute | Value |
|---|---|
| Brand Name | Hi-Link (bibikoo) |
| Model Number | 2W Series (2M03, 2M05, 2M09, 2M12, 2M15, 2M24) |
| Power | 2W |
| Power Source | AC |
| Voltage Range | High voltage (50-1000V DC, 75-1000V AC) |
| Efficiency | 69% |
| Certification | CE, RoHS |
| Origin | Mainland China |
| Inbox Adaptor | No |
| High-concerned chemical | None |
3.2. Environmental Conditions
| Item | Technical Parameters | Units |
|---|---|---|
| Working temperature | -25 to +60 | °C |
| Storage temperature | -40 to +80 | °C |
| Relative humidity | 5-95 | % |
| Thermal methods | Natural cooling | |
| Atmospheric pressure | 80-106 | Kpa |
| Altitude | <2000 | m |
| Vibration | 10-500Hz, 2G10min./1cycle, 60min.each along X,Y,Z axes |
3.3. Input Features
| Item | Technical Parameters | Units |
|---|---|---|
| Rated input voltage | 100-230 | Vac |
| Input voltage range | 90-245 | Vac |
| Maximum input current | ≤0.2 | A |
| Input inrush current | ≤10 | A |
| Rated input voltage | ≤250 | Vac |
| Input low start | ≤50 | mS |
| Input low voltage efficiency (Vin=110Vac, Output full load) | ≥69 | % |
| Input high voltage efficiency (Vin=220Vac, Output full load) | ≥70 | % |
| Long-term reliability (MTBF) | ≥100,000 | h |
| External fuse recommended | 0.5A/250Vac (Slow blow) |
3.4. Output Features by Model
The 2W series offers various output voltages. Below is a summary table, followed by detailed specifications for each model.
| Model | Output Power (W) | Output Voltage (V) | Output Current (mA) |
|---|---|---|---|
| HLK-2M03 | 2 | 3.3 | 600 |
| HLK-2M05 | 2 | 5 | 400 |
| HLK-2M09 | 2 | 9 | 230 |
| HLK-2M12 | 2 | 12 | 170 |
| HLK-2M15 | 2 | 15 | 130 |
| HLK-2M24 | 2 | 24 | 83 |
Detailed Output Features (Common to all models unless specified)
| Item | Technical Parameters | Units | Notes |
|---|---|---|---|
| No-load rated output voltage | Vout ±0.1 | Vdc | |
| Full-load rated output voltage | Vout ±0.2 | Vdc | |
| Voltage regulation | ±0.2 | % | |
| Load regulation | ±0.5 | % | |
| Output ripple and noise (mVp-p) | ≤50 (for 3.3V/5V), ≤70 (for 9V/12V/15V/24V) | mV | Rated input voltage, output full load. With 20MHz bandwidth oscilloscope, Load side 10uF and 0.1uF capacitance test. |
| Switching on/off overshoot amplitude | (Rated input voltage, output plus 10% load)≤ 5 | %Vo | |
| Output over-current protection | Output maximum load 110-200% (varies by model) | A | |
| Output short circuit protection | Direct short circuit in normal output and automatic return to normal operation after removal of short circuit | No-damage to the whole device |
3.5. Physical Dimensions and Weight
The module has compact dimensions, making it suitable for space-constrained applications.
- Size: 30mm × 16mm × 19mm (Length × Width × Height)
- Weight: Approximately 18g per piece
- Dimensional Error: ±1mm for length, width, height, and pin spacing. Pin length error: ±1mm. Pin diameter error: -0.2mm.
Note: The dimensions on the drawing are for reference only. The actual dimensions shall be subject to the physical product.
4. Installation and Application Circuit
The Hi-Link 2W series power modules are designed for straightforward integration into electronic circuits. They require minimal external components for basic operation.
4.1. Typical Application Circuit Overview
A typical application circuit for the power module includes input protection, filtering, and the power module itself, followed by the load. The circuit generally consists of a fuse (F1), a varistor (MOV1), an X-safety capacitance (C1), a common-mode inductance (L1), the power module, and an output filter capacitor (C2) connected to the load (RL).
Input Side:
- F1/Fuse: A 1A/250Vac slow-blow fuse is recommended to protect the circuit from damage in case of module malfunction.
- MOV1/Varistor: A 10D561K varistor is used to protect the module from cumulative surges.
- C1/X Safety capacitance: A 0.1uF/275Vac capacitor is used for filtering and safety protection (EMC certification).
- L1/Common-mode inductance: An inductance of 10-30mH (tested at 1KHZ/0.3V, current 100-500mA) is used for EMI filtering.
Output Side:
- C2/Filter capacitor: An aluminum electrolytic capacitor with a capacity of 100-220 μF is recommended. Adding this capacitor can control output ripple to within 30mV and achieve a voltage reduction greater than 75%.
- RL/Load: The power module connects directly to the intended load.
Important Note: The fuse and varistor are basic protective circuits and must be connected. If authentication/certification (e.g., UL, CE) is required, the safety capacitance and common-mode inductance cannot be omitted.
For a visual representation of the circuit, please refer to the "Typical application circuit" diagram in the full user manual PDF available at this link.
5. Operation Guidelines
To ensure optimal performance and longevity of your Hi-Link 2W series power module, adhere to the specified operating conditions.
5.1. Input Voltage and Load Characteristics
The module operates with a global universal input voltage range of 90-245Vac. The rated input voltage is 100-230Vac. The load capacity of the module is dependent on the input voltage. Generally, the module can sustain 100% load within the 100-230Vac input range. At the lower end of the input voltage range (e.g., 90Vac), the maximum load capacity may decrease. Conversely, at higher input voltages, the module maintains its rated output.
For a detailed graph illustrating the relationship between input voltage and load percentage, please consult the "Input voltage and load characteristics" diagram in the full user manual PDF.
5.2. Working Temperature and Load Characteristics
The module is designed to operate within a working temperature range of -25°C to +60°C. The maximum load capacity is also affected by the ambient temperature. At temperatures up to approximately 50°C, the module can typically sustain 100% load. Beyond this temperature, the load capacity may need to be derated to prevent overheating and ensure stable operation. For instance, at 60°C, the load capacity might be reduced to around 80%.
Refer to the "Working environment temperature and load characteristics" diagram in the full user manual PDF for specific derating curves.
6. Safety and Certifications
The Hi-Link 2W series power modules are designed with safety as a priority and comply with international standards.
6.1. Certifications
Product design meets UL and CE safety certification requirements. The modules are also RoHS certified, indicating compliance with restrictions on hazardous substances.
Note: UL and CE certifications are typically obtained by the customer and require design according to a reference circuit.
6.2. Safety and Electromagnetic Compatibility (EMC)
- Input Protection: The input design incorporates a UL listed 1A fuse for protection.
- PCB Material: The PCB board is made of double-sided copper clad foil with a material fire resistance grade of 94-V0.
- Safety Standards: Meets UL1012, EN60950, UL60950.
- Insulation Voltage: Input-to-Output (I/P-O/P) insulation voltage is 2500Vac.
- Insulation Resistance: Input-to-Output (I/P-O/P) insulation resistance is greater than 100M Ohms at 500Vdc, 25°C, 70% RH.
- Conduction and Radiation: Meets EN55011, EN55022 (CISPR22) standards.
- Electrostatic Discharge (ESD): Complies with IEC/EN 61000-4-2 level 4 (8kV/15kV).
- Radio Frequency Radiation Immunity: Complies with IEC/EN 61000-4-3.
7. Troubleshooting
This section provides guidance for common issues you might encounter with your power module.
- No Output Voltage:
- Check the input power supply: Ensure the AC input voltage is within the specified range (90-245Vac) and is stable.
- Check the input fuse (F1): A blown fuse indicates an overcurrent event. Replace with a 1A/250Vac slow-blow fuse after identifying and resolving the cause of the overcurrent.
- Verify connections: Ensure all input and output connections are secure and correctly wired according to the application circuit.
- Output Voltage Instability or Ripple:
- Check output load: Ensure the load does not exceed the module's rated output current. Overloading can cause voltage drops or instability.
- Verify output filter capacitor (C2): Ensure the recommended output filter capacitor (100-220 μF) is correctly installed and functioning. An insufficient or faulty capacitor can lead to increased ripple.
- Check for electromagnetic interference (EMI): Ensure proper shielding and grounding in your application to minimize external interference.
- Module Overheating:
- Check ambient temperature: Ensure the operating environment temperature is within -25°C to +60°C. High ambient temperatures can lead to overheating.
- Verify load: Reduce the load if operating at higher ambient temperatures, as per the load derating characteristics.
- Ensure proper ventilation: Although designed for natural cooling, ensure the module is not enclosed in a way that restricts airflow.
- Short Circuit Protection Triggered:
- The module features output short circuit protection and will automatically recover once the short circuit is removed. Identify and clear any short circuits on the output side.
- Over-current Protection Triggered:
- The module has over-current protection. Reduce the load to within the specified output current limits for your model. The module should recover automatically.
If issues persist after following these steps, please contact technical support.
8. Maintenance
The Hi-Link 2W series power modules are designed for high reliability and long life, requiring minimal maintenance.
- Cleaning: Keep the module free from dust and debris. If cleaning is necessary, use a soft, dry brush or compressed air. Avoid using liquids or solvents.
- Inspection: Periodically inspect the module for any signs of physical damage, loose connections, or discoloration which might indicate overheating.
- Environmental Control: Ensure the module operates within the specified temperature and humidity ranges to prevent premature aging of components.
- Component Replacement: In case of component failure (e.g., blown fuse), replace with an equivalent specified part. For internal component failures, contact technical support.
9. User Tips
Based on user feedback and common inquiries, here are some helpful tips for using your Hi-Link 2W series power module:
- Safety First: Always ensure proper input protection (fuse and varistor) is in place, especially when integrating into new projects. Hi-Link modules are known for meeting safety standards, but proper circuit design is crucial.
- Compact Design: The small size (30x16x19mm) and light weight (approx. 18g) make these modules ideal for compact projects where space is a premium.
- Certifications: The CE and RoHS certifications provide assurance of quality and compliance with environmental and safety directives.
- Reliable Performance: Users consistently report that these switch power supplies work as described and are reliable for their intended applications.
- Packaging: Modules are typically packed well in hard boxes to prevent damage during transit.
10. Warranty and Technical Support
10.1. Quality Guarantee
The Hi-Link 2W Ultra Small Series Power Module comes with a 1-year quality guarantee period from the date of purchase.
10.2. Technical Support and Contact Information
For technical assistance, inquiries, or support, please contact Shenzhen Hi-Link Electronic Co., Ltd. directly:
- Address: 17F, Building E, Xinghe WORLD, Minzhi Street, Longhua district, Shenzhen 518131, China
- Telephone: 0755-23152658
- Email: sales@hlktech.com
- Website: www.hlktech.net
11. Packaging, Transportation, and Storage
11.1. Product Marking
Each product features a unique barcode mark at an appropriate location to ensure traceability of manufacturing date, product batch, and other relevant information. Product markings comply with national and industry standards.
11.2. Packaging Marking
Product packaging boxes are marked with the manufacturer's name, site, zip code, product model, and factory year, month, and day. They also include transport signs such as "up", "moisture-proof", and "fragile" (implied by "carefree" in context of transport signs). All signs conform to GB 191 provisions.
11.3. Packaging
Products are packaged using special plastic boxes with separated compartments, providing anti-vibration functionality. This packaging complies with GB 3873 provisions.
11.4. Transportation
Packaged products can be transported by any means. During transit, they should be protected by an awning and subjected to no violent vibration, impact, or other harsh conditions. This ensures the integrity of the product.
11.5. Storage
Product storage must meet the requirements specified in GB3873. Generally, this implies storage in a dry, well-ventilated area, free from corrosive gases, and within specified temperature and humidity limits to prevent degradation.
For the complete and detailed user manual, including all diagrams and technical drawings, please refer to the official PDF document: Hi-Link 2W Ultra Small Series Power Module User Manual (PDF).