1. Introduction
Thank you for choosing the PowMr MPPT series solar charge controller. This manual provides essential information for the safe installation, operation, and maintenance of your charge controller. Please read it carefully to ensure proper use and to maximize the benefits for your solar system.
The PowMr MPPT 60A Solar Charge Controller is an advanced Maximum Power Point Tracking (MPPT) solution designed for solar systems. It boasts a conversion efficiency of up to 97% and a tracking efficiency of 99.9%, ensuring optimal power harvesting from your solar panels. It features a high-performance DSP controller for fast digital signal processing and supports a wide range of battery voltages (12V, 24V, 36V, 48V).

Figure 1: PowMr MPPT 60A Solar Charge Controller highlighting 60A Max Charge Current, 12V/24V/36V/48V Battery Voltage Range, 160VDC Max PV Input, and ≥99% PV Utilization.
Video 1: Product overview and key features of the HHJ-60A Solar Charge Controller, demonstrating its 60A charging capacity, high tracking efficiency, DSP controller, wide voltage compatibility, segmented charging, and built-in protections.
2. Important Safety Instructions
Please save these instructions.
This manual contains important safety, installation, and operating instructions for the charge controller. The following symbols are used throughout the manual to indicate potentially dangerous conditions or important safety information:
- WARNING: Indicates a potentially dangerous condition. Use extreme caution when performing this task.
- CAUTION: Indicates a critical procedure for safe and proper operation of the controller.
- NOTE: Indicates a procedure or function that is important to the safe and proper operation of the controller.
2.1. General Safety Information
- Read all instructions and cautions in this manual before beginning installation.
- There are no serviceable parts inside this controller. DO NOT disassemble or attempt to repair the controller.
- DO NOT allow water to enter the controller.
- Make sure all connections going into and from the controller are tight.
2.2. Charge Controller Safety
- WARNING: NEVER connect the solar panel array to the controller without a battery. The battery must be connected first.
- Ensure input voltage does not exceed 160 VDC to prevent permanent damage. Use the Open Circuit Voltage (Voc) to make sure the voltage does not exceed this value when connecting panels together.
2.3. Battery Safety
- Use only sealed lead-acid, flooded, gel, or lithium batteries which must be deep cycle.
- Explosive battery gases may be present while charging. Be certain there is enough ventilation to release the gases.
- Be careful when working with large lead-acid batteries. Wear eye protection and have fresh water available in case there is contact with battery acid.
- Carefully read battery manuals before operation.
- DO NOT let the positive (+) and negative (-) terminals of the battery touch each other.
- Over-charging and excessive gas precipitation may damage battery plates and activate material shedding on them. Too high of an equalizing charge or too long of one may cause damage. Please carefully review the specific requirements of the battery used in the system.
- Equalization is carried out only for non-sealed / vented / flooded / wet cell lead-acid batteries.
- DO NOT equalize VRLA type AGM / Gel / Lithium cell batteries UNLESS permitted by the battery manufacturer.
Connect battery terminals to the charge controller BEFORE connecting the solar panel(s) to the charge controller. NEVER connect solar panels to charge controller until the battery is connected.
DO NOT connect any inverters or battery charger into the load terminal of the charge controller.
Once equalization is active in the battery charging, it will not exit this stage unless there is adequate charging current from the solar panel. There should be NO load on the batteries when in equalization charging stage.
3. Setup and Installation
The controller dimensions are approximately 21.4cm x 11.5cm x 5cm. Ensure adequate space for installation and ventilation.

Figure 2: Dimensions of the PowMr MPPT 60A Solar Charge Controller (21.4cm x 11.5cm x 5cm).
3.1. Installation Notes
NOTE: Use only the provided screws for installation. Using other screws may damage the internal PCB. Apply proper torque to push the screws into the casing to avoid damaging the internal PCB.
3.2. Wiring Sequence
Connections must always be made in the following sequence:
- Connect the batteries: Connect the battery connection cable with the correct polarity to the middle pair of terminals on the solar charge controller (marked with the battery symbol). If the system is 12V, ensure your battery voltage is above 12V for the controller to boot up.
- Connect the solar panel: Ensure that the PV modules are protected from incident light and that the solar panel input does not exceed the maximum permissible input current. Connect the PV modules connection cable to the correct polarity of the left pair of terminals on the solar charge controller (marked with the PV modules symbol).
- Connect loads: Connect the load cable to the correct polarity of the right pair of terminals on the solar charge controller (marked with the lamp symbol). To avoid any voltage on the wires, connect the wire to the load before connecting to the controller.
- Final check: Tighten all cables connected to the controller and remove all debris around the controller (leaving a space of approximately 5.91 inches for ventilation).

Figure 3: Wiring diagram showing connections for PV Solar Panels, MPPT Charge Controller, Battery, DC Load, and Inverter. Supports parallel connection of two 60A controllers for 120A total.

Figure 4: Illustration of the 3-stage charging process (Equalize, Boost, Float) for rapid, efficient, and safe charging, optimizing battery life.
3.3. Air Circuit Breaker Installation
We strongly recommend connecting a fuse directly to the battery to protect against any short circuit in the battery wiring. Solar PV modules generate current whenever light strikes them. Protect the solar modules from incident light during installation. Never touch uninsulated cable ends, use only insulated tools, and ensure the wire diameter is in accordance with the expected currents of the solar charge controller.
| Models | Copper wires | Air circuit breakers |
|---|---|---|
| MPPT-60A | 6mm²x2PCS | 100A |
3.4. Connection Diagram
It's recommended to connect two wires to two PV+ and another two wires to two PV-. For BAT+ and BAT-, the same wiring method applies.

Figure 5: Detailed connection diagram for the MPPT Solar Charge Controller, including PV, Battery, and DC Load connections with circuit breakers.
- Install air circuit breaker between controller and batteries. Turn off the circuit breaker, then connect batteries to controller with correct polarity.
- Install air circuit breaker between controller and PV modules. Turn off the circuit breaker, and ensure the PV polarity is correct, then connect wires between PV modules and controller.
- Turn on the air circuit breaker between controller and batteries.
- Turn on the air circuit breaker between controller and PV modules.
- The controller goes into self-test mode. Its LCD displays parameters if all is correct. The RUN lamp (under the fan inside the casing) will flash every one second. If the controller does not respond, please re-read the manual or contact support.
4. Operation
4.1. LCD Display
The LCD display provides real-time information about the system's status. The main interface shows PV voltage/output power, battery voltage/charging current, working mode/temperature, and fault codes. Various sub-interfaces allow for detailed monitoring and setting adjustments.

Figure 6: Detailed view of the LCD display, showing main interface parameters, sub-interfaces for load timer, floating voltage, absorption voltage, calibration voltage, battery type, and under-voltage disconnection voltage. Also illustrates fan cooling.
| Item | Description |
|---|---|
| 1 | PV voltage / Output power |
| 2 | Battery voltage / Charging current |
| 3 | Working mode / Temperature |
| 4 | Fault code |
4.2. Working Mode
| Mode | Description |
|---|---|
| 3.0 | Night mode, no charging |
| 4.0 | MPPT mode |
| 7.0 | Absorption mode |
| 8.0 | Floating mode |
4.3. Manual Setting
Reminder: The controller will work fine under default settings except for lithium batteries.
- Step 1: D00 (Load Timer)
Press the PRG button. The LCD displays D00. This setting is for load working time (default is 24-hour). Press ENT until numbers flash, then use UP/DOWN to set the desired time. Long-press ENT to confirm. This output voltage is the same as the battery voltage. The load is only for small DC loads less than 5A current. If no load, leave it as is. - Step 2: D01 (Floating Voltage)
Press the UP button. The LCD shows 13.8 (default value for floating charging). Press ENT until numbers flash, then use UP/DOWN to set the desired voltage. Long-press ENT to confirm. - Step 3: D02 (Absorption Voltage)
Continue to press the UP button. The LCD shows 14.5 (highest absorption charging voltage for battery). Press ENT until numbers flash, then use UP/DOWN to set the desired voltage. Long-press ENT to confirm. - Step 4: D03 (Under-voltage Disconnection)
Continue to press the UP button. The LCD shows 10.0. This is the protection value for battery discharge. Press ENT until numbers flash, then use UP/DOWN to set the desired voltage. Long-press ENT to confirm. This means if a 12V battery drops below 10.0V, there will be no output power from OU+ and OU-. - Step 5: D04 (Battery Type)
Continue to press the UP button. The LCD shows 00.00 (default for acid batteries). If it's for a lithium battery, press ENT until numbers flash, then use UP/DOWN to choose 01. Long-press ENT to confirm. Note that Step 2 (D01) is not used for lithium batteries. The voltage set in Step 3 (D02) will be the highest charging voltage for lithium batteries. - Step 6: D05 (Battery Voltage Calibration)
Continue to press the UP button. The LCD shows C+ "the currently detected battery voltage". This setting item is used to calibrate the battery voltage by adjusting the value, ensuring that the battery voltage detected by the controller matches the actual battery voltage.
Press ESC to exit the setting menu.
Reminder: After setting all steps, please disconnect the battery. Then reconnect the controller to see if all settings are successful. Once all settings are confirmed, connect the PV modules to the controller.
4.4. Batteries Charge Voltage Reference
| Battery Type | Absorption Voltage (Constant Voltage) | Floating Voltage | ||||
|---|---|---|---|---|---|---|
| 12V | 24V | 48V | 12V | 24V | 48V | |
| Vented | 14.2V | 28.6V | 57.2V | 13.2V | 26.4V | 52.80V |
| Sealed | 14.4V | 28.8V | 57.6V | 13.8V | 27.6V | 55.2V |
| Gel | 14.4V | 28.8V | 57.6V | 13.8V | 27.6V | 55.2V |
| NiCd | 14.2V | 28.6V | 57.2V | 14.0V | 28.0V | 56.0V |
| Lithium or others | Defined by users | |||||
5. Maintenance
Regular maintenance ensures the longevity and optimal performance of your solar charge controller.
- Periodically check all wiring connections to ensure they are tight and free from corrosion.
- Keep the controller clean and free from dust and debris. The fan uses bearing technologies for increased lifespan, but a clean environment helps.
- Monitor the LCD display for any fault codes or unusual readings.
- Ensure adequate ventilation around the controller to prevent overheating. The fan will activate automatically when needed.
6. Troubleshooting and Protections
6.1. Troubleshooting
NOTE: When the reading data of PV or battery is constantly changing, do not worry. The controller is finding the MPPT point. This can be caused by insufficient PV input power or voltage. Contact our technical team if the issue persists.
| Code | Description | How to solve |
|---|---|---|
| 18 | Input PV voltage is low | Increase the PV voltage |
| 60 | Over-temperature protection | Fan will work and temperature reduction automatically |
| 63 | Battery voltage is high | Battery high voltage protection and wait for recovery |
| 65 | Battery voltage is low | Battery over-discharge and wait for recovery |
| 71 | Input PV voltage is high | Decrease the PV voltage |
| 73 | Over-charging current | Decrease the PV power |
6.2. Protections
The PowMr MPPT 60A Solar Charge Controller includes multiple built-in protection features to ensure safety and system longevity:

Figure 7: Icons representing multi-function protection features including load short circuit, battery over-discharge, battery reverse polarity, PV short circuit, PV over-current alarm, battery overcharge, controller overheating, and load overload protection.
- PV Over Current: The controller will limit charging power to the rated charge power. An over-sized PV array will not operate at its maximum power point.
- PV Short Circuit: When a PV short circuit occurs, the controller will stop charging. Remove the short to resume normal operation.
- PV Reverse Polarity: Full protection against PV reverse polarity. No damage to the controller. Correct the connection to start normal operation.
- Battery Over Voltage: If other energy sources charge the battery, and the battery voltage exceeds 15.5V (for 12V system, adjust proportionally for higher voltages), the controller will stop charging to protect the battery from overcharging damage. (Note: Stop charging means charging current is very low).
- Battery Over Discharge: When battery voltage drops to the set low voltage disconnect point, the controller will stop discharging to protect the battery from over-discharging damage.
- Load Over Current Protection: If the load current exceeds 1.25 times the maximum load current rating, the controller will disconnect the load.
- Load Short Circuit Protection: Once a load short circuit happens, the load short circuit protection will start automatically.
- Over Temperature Protection: The controller is equipped with over-temperature protection. The fan will activate to cool the unit, and if temperatures remain too high, the controller will reduce power or shut down to prevent damage.
7. Technical Specifications
| Parameter | Specification |
|---|---|
| Model | HHJ-60A |
| Charging mode | 3-stage: constant current (MPPT), 4-constant voltage, Floating |
| Max.PV Input Power (12V system) | 720W |
| Max.PV Input Power (24V system) | 1440W |
| Max.PV Input Power (36V system) | 2100W |
| Max.PV Input Power (48V system) | 2800W |
| Input specification DC (12V system) | 20V~80V |
| Input specification DC (24V system) | 37V~105V |
| Input specification DC (36V system) | 50V~160V |
| Input specification DC (48V system) | 72V~160V |
| Battery voltage automatic recognition (12V system) | DC9V~DC15V |
| Battery voltage automatic recognition (24V system) | DC18V~DC29V |
| Battery voltage automatic recognition (36V system) | DC30V~DC39V |
| Battery voltage automatic recognition (48V system) | DC40V~DC60V |
| Overcharging protection voltage | 60V |
| Limited current protection | 61A |
| Max efficiency | ≥98.1% |
| PV utilization | ≥99% |
| Temperature protection | 75°C / 167°F |
| Fan-on temperature | >45°C / 104°F |
| Fan-off temperature | <40°C / 95°F |
| Size (mm)/(in) | 214x115x50mm / 8.43x4.53x1.97in |
| Net weight(Kg)/(lb) | 1.1 / 2.43 |
| Gross weight(Kg)/(lb) | 1.2 / 2.65 |
| Electromagnetic compatibility | Accord to EN61000, EN55022, EN55024 |
| Enclosure | IP21 |
| Environmental temperature | -20°C ~ +55°C |
| Storage temperature | -40°C ~ +75°C |
8. Content Included
The product package includes the following items:
- 1x MPPT Solar Charge Controller
- 4x Corner connections
- 4x Screws for controller casing
- 1x English manual (this document)
9. User Tips
- Installation Sequence: Always connect the battery to the controller before connecting solar panels. The controller will detect the battery voltage upon connection.
- Lithium Battery Configuration: For Lithium batteries, specific settings are required. Refer to the "Manual Setting" section (Step 5: D04) to select the correct battery type (01 for Lithium) and adjust charging voltages accordingly.
- Charging Modes: Familiarize yourself with the different charging modes (Night, MPPT, Absorption, Floating) to understand the controller's behavior and ensure optimal battery charging.
- Cooling Fan Operation: The internal cooling fan operates only when necessary, indicating efficient thermal management. It is normal for the fan to activate rarely.
- Power Output Stability: Ensure your solar panel array and battery bank are appropriately sized and configured for your system voltage (12V, 24V, 36V, 48V) to maintain stable power output. Incompatible setups may lead to unstable power readings.
10. Warranty and Support
10.1. Warranty Regulations
- Within 30 days from the date of purchase, a faulty controller will be replaced free of charge under normal use (with authorization from technical personnel).
- Within 2 years from the date of purchase, a faulty controller will be repaired free of charge.
Notes: Disassembled privately, no warranty.
10.2. Liability Disclaimer
The manufacturer shall not be liable for damages, especially to the battery, caused by use other than as intended or as mentioned in this manual, or if the recommendations of the battery manufacturer are neglected. The manufacturer shall not be liable if there has been service or repair carried out by any unauthorized person, unusual use, wrong installation, or bad system design.
10.3. Contact Information
For any questions or support, please contact us:
- Tel/Fax: +86 755-28219903
- Email: support@powmr.com
- Web: www.powmr.com
- Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China