ToolkitRC ST8

Contents

ToolkitRC ST8 Multi-function Servo Tester

User Manual

Introduction

Thank you for purchasing the ST8 Multi-function servo tester. Please read this manual carefully before use to ensure proper operation and longevity of your device.

Key Points

  • Tips: Helpful advice for optimal use.
  • Important: Critical information to note.
  • Information: General details about features and functions.

For further details, video tutorials, and the latest information, please visit the official ToolkitRC website: www.toolkitrc.com.

Safety Precautions

Failure to follow these safety instructions may result in damage to the product, property, or personal injury.

  1. The ST8 allows an input voltage of 7-28V. Ensure the power supply voltage is consistent and pay attention to the positive and negative polarity when connecting.
  2. The S1-S4 and S4 Ext. signal ports support a maximum of 2A current. For larger current servos, connect to the output main port to prevent internal circuit damage.
  3. The S1-S4 signal port can only output up to 8.4V. For higher voltage requirements, use the main output port.
  4. Do not use this product in environments with high heat, humidity, flammable materials, or explosive atmospheres.
  5. Do not leave this product unattended while in use to prevent accidents.
  6. Always unplug the input power when the product is not in use.

Product Overview

The ToolkitRC ST8 is a versatile servo testing device featuring up to 28V voltage output, 8-channel signal output, current measurement, and curve display capabilities.

  • 4 channels of programmable independent signal, 8 channels of signal output, with 1ms accuracy.
  • 4 independent current acquisition channels with curve display.
  • Multiple measurement modes: speed, count, step, linear.
  • Outputs PWM signals with a period of 33 to 1000 Hz.
  • Various signal trigger sources: internal, buttons, knobs, external sources.
  • Measures servo response speed with 1ms accuracy.
  • External input signal supports PWM/PPM/SBUS with 1ms accuracy.
  • Drives servos with a maximum load of 100W.
  • Multi-language system with firmware upgrade capability.
  • Device functions as a USB flash drive for easy firmware upgrades.

Setup

ST8 Layout

Familiarize yourself with the device's ports and controls:

ToolkitRC ST8 Front Layout Diagram

Figure 1: Front Layout of ST8 Servo Tester
This diagram shows the front panel components: Display, Exit button, OK knob (with press function), P1 knob (with press/lock function), S5 signal port (Input PWM/PPM/SBUS), and MicroUSB 3.0 port.

ToolkitRC ST8 Back Layout Diagram

Figure 2: Back Layout of ST8 Servo Tester
This diagram shows the rear panel components: XT60 Input (DC 7-28V@MAX 10A), XT60 Output (5.0V-28.0V@MAX 10A), S1-S4 Signal Ports (5.0V-8.4V@MAX 4A), and S4 EXT Signal Port (5.0V-8.4V@MAX 4A).

First Start

  1. Connect a 7-28V power supply to the XT60 input port on the back of the ST8.
  2. The display will show the boot logo for 2 seconds.
  3. A "do-re-mi" boot sound will play.
  4. After booting, the display will enter the main interface.

Basic Operation

  • [Exit] Button: Short press to start PWM signal output and testing. Also used to pause, start, or exit functions.
  • [Knob] (OK): Rotate to move the cursor and select different channels. Press to confirm selection, open channel settings, and set input/output signals. Long press (2 seconds) to enter the system setup menu. Short press to determine key function.
  • Any successful key operation will be accompanied by an audible prompt tone.

Operating Instructions

Main Interface

After powering on and pressing [Exit], the system displays the main interface:

ToolkitRC ST8 Main Interface Display

Figure 3: Main Operating Interface
This image shows the ST8 connected to a servo and battery, displaying real-time signal output, current curves, and various parameters on its TFT screen.

  • Top Display: Shows output voltage (main port or PWM), PWM output frequency/period, input voltage, and motherboard temperature. Alarms (flashing red) occur if input voltage is too low or temperature is too high.
  • Right Side (S1-S4): Independent 4-channel PWM signals, distinguished by color.
  • Middle Grid: Curve display of 4 PWM output currents, color-coded for easy distinction.
  • Output Bar: Displays maximum current, speed, and count for each channel in real-time.
  • PS, PC, PE Buttons: Located in the lower right corner. Become selectable when button source mode is chosen.

Pause Interface

From the main interface, press [Exit] to enter the pause interface. The current curve is paused, and the PWM signal maintains a fixed value. Rotate the [Knob] to adjust the timeline and view saved current curves. Press [Exit] again to exit the pause interface.

Channel Setting

Select a channel on the main interface and press [OK] to access its settings. You can configure various parameters for each channel:

  • Signal Source Setting: Rotate [Knob] to [Input] position, press [OK] to modify.
    • Channel 1: P1, S5, internal signal, button (4 sources).
    • Channels 2-4: P1, S5, internal signals, buttons, channel 1 (5 sources).
  • P1 Source Setting: When P1 is selected, PWM output is controlled by the P1 knob, and its position is displayed.
  • S5 Source Setting: When S5 is selected, PWM, PPM, and SBUS signals can be chosen. Input the corresponding signal on the S5 interface to display the received signal value and control PWM output.
    ToolkitRC ST8 External Signal Sources Display

    Figure 4: External Signal Source Options
    This image illustrates the display when using external sources, showing options for PWM, PPM, and SBUS inputs.

    • PPM: Channel can be set from CH0 to CH7.
    • SBUS: Channel can be set from CH0 to CH15.
  • Internal Source Setting: For aging servo tests, set to linear or phase modes.
    • Linear Mode: Set step value (1-10 microseconds) and speed value (1-10 milliseconds).
    • Phase Mode: Measures servo response speed. Jumps between PS, PE (second-order) or PS, PC, PE (third-order) values at 1-second intervals.
  • Key Setting: When "button" is selected as the signal source, PS, PC, PE buttons appear on the main interface. Move cursor to buttons and short press [OK] to output corresponding PWM value. Angle turn time can be measured.
  • S1 Source Setting: If S2, S3, S4 signal sources select S1, they will follow S1's settings and output the same PWM value.
  • Output Source Setting: Move cursor to [Output] to set PWM output signal range (1 microsecond accuracy). Set PC value in button source and internal source stage modes.

System Setting

Press and hold [OK] for 2 seconds on the main interface to enter the system settings. Rotate [Knob] to switch between settings:

SettingDescription
CyclePWM signal period (1ms to 30ms).
VoltageOutputMain port output voltage (Turnoff, 5V, 6V, 7.4V, 8.4V, 12V, 14V, 15V, 16V, 18V, 24V, 28V). PWM port is 5V when main port is off.
CycleCountFor internal signal source, stops operation after set number of cycles.
LowestInputDevice stops main port output below this voltage.
SafeTemperatureDevice stops main port output above this temperature.
BacklightDisplay backlight brightness level (1-10).
BuzzerBuzzer tone (on/off).
LanguageSystem display language (English, Chinese).
ThemeStyleSystem interface color style (bright, dark).
KNOBCalibrateCalibrates P1 knob's maximum and minimum values.
CycleCountClearClears the count under the internal source.
DefaultRestores all settings to factory defaults.

Maintenance

Firmware Upgrade

To ensure your ST8 has the latest features and bug fixes, you can upgrade its firmware:

  1. Connect the ST8 to your computer using the USB cable provided in the box.
  2. Your computer will recognize the ST8 as a USB flash drive named "Toolkit".
  3. Download the latest firmware file (e.g., app.upg) from the official ToolkitRC website.
  4. Copy and overwrite the existing firmware file on the "Toolkit" USB flash drive with the downloaded file.
  5. Safely eject the USB drive from your computer. The ST8 will then update its firmware.

Troubleshooting

  • Device Error/Freeze with High Current Servos: If the device encounters an error or freezes when testing strong digital servos with large current consumption, especially when using more than three servos simultaneously, disconnect the power battery and restart the device.
  • No Display/Power: Ensure the input power supply is within the 7-28V range and correctly connected with proper polarity. Check the power cable for damage.
  • Incorrect Servo Readings: Verify that the servo connections are secure and correctly oriented (signal, positive, negative). Ensure the selected channel settings match the servo type and desired test parameters.
  • Firmware Update Issues: Ensure the firmware file is correctly downloaded and placed in the root directory of the "Toolkit" USB drive. Use a reliable USB cable.

Specifications

FeatureValue
Input Voltage7-28V @ MAX 10A
Main Output Port5.0V-28.0V @ MAX 10A
Signal Port Output (S1-S4)5.0V-8.4V @ MAX 4A
Signal Port Output (S4 Ext.)5.0V-8.4V @ MAX 4A
Output Signal (S1-S4)100us-2900us @ 33-1000Hz
Output Signal (S5 PWM)500us-2500us
Output Signal (S5 PPM)8CH
Output Signal (S5 SBUS)16CH
P1 Rotation Range1000us-2000us
MicroUSBUpgrade @ USB3.0
LCD Display2.4 inch TFT RGB 320*240 resolution
Product Size99mm * 68mm * 26mm
Product Weight140g
Packaging Size105mm * 80mm * 45mm
Packaging Weight160g

User Tips

  • Voltage Selection: Utilize the output voltage selection in the system settings to prevent overloading your servos, especially when testing different types.
  • Power Supply: A lithium-ion battery with an XT60 connector is a convenient and effective power source for the ST8.
  • Operating Frequency: Experiment with different operating frequencies to match the requirements of your specific servos.
  • Current Monitoring: Pay attention to the real-time mA consumption display; it's a valuable tool for analyzing servo performance, identifying binding issues, or checking damaged servos.
  • Comprehensive Analysis: The ST8 is a proper instrument for in-depth servo analysis, offering great graphics and detailed information to understand servo behavior.

Warranty and Support

For warranty information, technical support, and further assistance, please refer to the official ToolkitRC website or contact their customer service directly.

Official Website: www.toolkitrc.com

You can also refer to the original user manual PDF for additional details: ToolkitRC ST8 User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.