ToolkitRC MC8

Contents

ToolkitRC MC8 SC100 Multi-Checker User Manual

Model: MC8 | Version: 1.0 | Date: 2021.10

1. Introduction

1.1. Foreword

Thank you for purchasing the MC8 multi-checker. Please read through this manual carefully prior to operating the device. This manual provides essential information for the safe and efficient use of your device.

1.2. Product Overview

The MC8 is a compact multi-checker designed for every hobbyist. Featuring a bright, color IPS display, it provides accurate measurements down to 5mV.

  • Measures and balances LiPo, LiHV, LiFe, and Lion batteries.
  • Wide voltage input: DC 7.0-35.0V.
  • Supports Main/Balance/Signal port power inputs.
  • Measures and outputs PWM, PPM, SBUS signals.
  • USB-A, USB-C dual-port output.
  • USB-C 20W PD fast charge output.
  • Battery over-discharge protection: Automatically disables USB output when battery reaches critical levels.
  • Measurement and balance accuracy: <0.005V.
  • Balance current: 60mA.
  • 2.0 inch, IPS full viewing angle display.
  • High resolution: 320*240 pixels.

For more detailed information and updates, please visit the official ToolkitRC website: www.toolkitrc.com/mc8

A comprehensive PDF version of this manual is also available for download from the manufacturer's website: MC8 User Manual (PDF)

2. Safety Precautions

WARNING: Failure to follow these safety instructions may result in fire, electric shock, injury, or damage to the product or other property.

  1. The operational voltage of the MC8 is between DC 7.0V and 35.0V. Ensure the polarity of the power source is not reversed prior to use.
  2. Do not operate under extreme heat, humidity, flammable, or explosive environments.
  3. Never leave the device unattended when in operation.
  4. Disconnect the power source when the device is not in use.

3. Device Layout and Components

3.1. Front View

Front layout of ToolkitRC MC8 Multi-Checker

Figure 1: Front view of the MC8, showing IPS Display, Signal port, Balance port, and Main input.

  • IPS Display: High-resolution color screen for displaying information.
  • Signal Port: Used for signal measurement and output (PWM, PPM, SBUS).
  • Balance Port: Connects to battery balance leads for cell voltage monitoring and balancing (2-8S).
  • Main Input (XT60): Connects to the main battery lead for total voltage measurement and power input (7-35V).

3.2. Rear View and Controls

Side view of ToolkitRC MC8 Multi-Checker showing USB ports

Figure 2: Side view of the MC8, showing USB-C and USB-A ports.

ToolkitRC MC8 Multi-Checker with metal roller and slider controls

Figure 3: MC8 controls, highlighting the metal roller and output slider.

  • Metal Roller: Used for UI navigation (scrolling through menus and options) and selection (short/long press).
  • Output Slider: Innovative slider control for adjusting channel output in signal generation modes.
  • USB-C Port: For 20W PD fast charging output and firmware upgrades.
  • USB-A Port: For 5V 1A charging output and firmware upgrades.

3.3. Package Contents

Contents of ToolkitRC MC8 Multi-Checker package

Figure 4: MC8 package contents: Multi-Checker, USB cable, and quick manual.

Video 1: Unboxing the ToolkitRC MC8 Multi-Checker.

4. Setup and First Use

  1. Powering On: Connect a battery to the MC8's balance port (2-8S), or connect a 7.0-35.0V power source to the XT60 input port.
  2. Boot Sequence: The screen will display the ToolkitRC boot logo for approximately 0.5 seconds.
  3. Main Interface: After booting, the device will enter the main interface, typically displaying cell voltage readings.
  4. Navigation:
    • Turn the metal roller to scroll between menus and options.
    • Short press the roller to enter a selected item or confirm an action.
    • Long press the roller for specific functions (e.g., starting balance, entering settings).
    • Use the output slider to adjust channel output in signal generation modes.

5. Operating Instructions

5.1. Voltage Test

5.1.1. Individual Cell Voltage Display and Balance

  1. Connect the balance port of your battery to the MC8.
  2. The main page will display the voltage of each individual cell. The cell with the highest voltage will be highlighted in red, and the lowest in blue. The total voltage and voltage difference (highest-lowest) are also shown.
  3. To start balancing, long press the metal roller for more than 2 seconds on the main menu. The MC8 will use internal resistors to discharge higher voltage cells until the pack reaches a uniform voltage (<0.005V difference between cells).

Note: The colored bars are calibrated for LiPo batteries. After balancing, remove the battery from the MC8 to prevent over-discharging.

5.1.2. Battery Pack Total Voltage

  1. Connect the main lead of your battery to the XT60 port on the MC8.
  2. The device will display the total voltage of the battery pack.

Note: The MC8 displays the total voltage for all battery chemistries operating within the input limits.

5.2. Signal Measurement

To enter Measure mode, scroll right once on the metal roller from the main interface. The signal port, balance port, and main input port can all supply power to the MC8 during signal measurement.

5.2.1. PWM Signal Measurement

  1. In Measure mode, the default display is PWM.
  2. The screen will show the current PWM pulse width (e.g., 1500us) and the cycle/frequency (e.g., 20ms/50Hz).

5.2.2. PPM Signal Measurement

  1. From PWM signal measurement mode, press down on the roller and scroll right until PPM is displayed.
  2. The screen will show the pulse width for each of the 8 PPM channels.

5.2.3. SBUS Signal Measurement

  1. From PPM signal measurement mode, press down on the roller and scroll right until SBUS is displayed.
  2. The screen will show the pulse width for each of the 16 SBUS channels, along with DG1/DG2 status and Lost/Fail indicators.

5.3. Signal Output

To enter Output mode, scroll right twice on the metal roller from the main interface. Press down on the roller for 2 seconds to enter the signal output mode.

5.3.1. PWM Signal Output

  1. Select PWM in Output mode.
  2. Mode: Change between Manual and 3 automatic modes of varying speeds.
  3. Width: PWM signal output pulse width (range 1000us-2000us). In Manual mode, use the output slider to adjust. In automatic modes, width changes automatically.
  4. Cycle: PWM signal output cycle (range 1ms-50ms).

Note: If the cycle is set to less than 2ms, the maximum width will not exceed the cycle value. The channel output slider is safety protected; no signal output will occur until the slider is returned to its minimum position first.

5.3.2. PPM Signal Output

  1. From PWM output page, short press on PWM to change output type, scroll right until PPM is displayed, then short press to confirm.
  2. Press down on the roller for 2 seconds to set the output value of each channel.

Note: The throttle channel can only be controlled by the output slider. Ensure the output slider is at its lowest point prior to performing any tests.

5.3.3. SBUS Signal Output

  1. From PPM output page, short press on PPM to change output type, scroll right until SBUS is displayed, then short press to confirm.
  2. Press down on the roller for 2 seconds to set the output value of each channel.

Note: If the cycle is set to less than 2ms, the maximum width will not exceed the cycle value. The channel output slider is safety protected; no signal output will occur until the slider is returned to its minimum position first.

5.4. USB Charging

The MC8 features built-in USB ports to charge mobile devices. The USB-A port supplies 5V 1A, while the USB-C port supplies 20W fast charging (PD3.0, QC3.0, AFC, SCP, FCP protocols).

Important: When charging USB devices, always connect the balance port of the source battery. If any individual cell reaches 3.0V or below, the USB output will automatically stop to prevent battery damage.

6. Calibration

To enter calibration mode, press and hold the metal roller while powering on the MC8.

  1. Measure the voltage of a fully-charged battery pack using a multimeter with 0.001V accuracy.
  2. Use the roller to select 'Input', then scroll until the displayed value matches your multimeter reading.
  3. Scroll down to 'Save' and press the roller to save.
  4. Repeat this process for each individual cell (1-8) if needed, comparing with multimeter readings.
  5. When finished, scroll to 'Exit' and press the roller to finish the calibration.

Note: Only use multimeters with 0.001V accuracy for calibration. If your multimeter is not accurate enough, do not perform calibration.

7. Maintenance

  • Keep the device clean and free from dust and debris. Use a soft, dry cloth for cleaning.
  • Avoid exposing the device to extreme temperatures, direct sunlight, or moisture.
  • Store the device in a cool, dry place when not in use.
  • Do not attempt to disassemble or modify the device, as this will void the warranty and may cause damage.

8. Troubleshooting

Device feels warm during operation:
It is normal for the MC8 to generate some heat, especially during battery balancing or when using the USB output, as these functions involve power dissipation. Ensure adequate ventilation.
Screen does not turn off automatically:
The MC8's display is designed to remain on during operation to provide continuous feedback. This is a characteristic of the device and not a fault. Disconnect the power source when not in use to conserve battery.
Unusual smell on first use:
A slight smell may occur during the initial few uses as internal components settle. If the smell persists, is strong, or accompanied by smoke, discontinue use immediately and contact support.
USB charging not working:
Ensure the source battery's balance port is connected and individual cell voltages are above 3.0V. Check the USB cable and the device being charged.

9. Specifications

CategoryParameterValue
GeneralMain Input PortXT60 7.0V-35.0V
Balance Input0.5V-5.0V Lixx 2-8S
Signal Port Input<6.0V
Balance CurrentMAX 60mA @2-8S
AccuracyBalance Accuracy<0.005V @ 4.2V
USB OutputUSB-A Output5.0V@1.0A (Firmware Upgrade)
USB-C Output5.0V-12.0V @MAX 20W
USB-C ProtocolPD3.0 QC3.0 AFC SCP FCP
MeasurementPWM500-2500us @20-400Hz
PPM880-2200us*8CH @20-50Hz
SBUS880-2200us *16CH @20-100Hz
OutputPWM1000-2000us @20-1000Hz
PPM880-2200us*8CH @50Hz
SBUS880-2200us *16CH @74Hz
ProductSize68mm*50mm*15mm
Weight50g
PackageSize76mm*60mm*30mm
Weight100g
DisplayLCDIPS 2.0 inch 240*240 resolution

10. User Tips

  • Versatile Tool: Many users find the MC8 replaces multiple devices, acting as both a battery checker and a servo tester, making it a highly functional and compact gadget.
  • Power Bank Functionality: The device can utilize power from an FPV battery (via XT60) to charge other devices via its USB-C or USB-A ports, effectively acting as a portable power bank.
  • No External Power Needed: For basic battery checking, simply connect it to the balancer port; no additional power source is required.
  • Monitor Heat: While some heat is normal during balancing or USB output, be mindful of excessive heat. Ensure good airflow around the device.
  • Screen Always On: The screen remains on during operation. Remember to disconnect the battery when not in use to prevent unnecessary drain.

11. Warranty and Support

ToolkitRC products are manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please refer to the official ToolkitRC website or contact your authorized dealer.

Please retain your proof of purchase for any warranty claims.

© 2021 ToolkitRC Co., LTD. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.