1. Introduction

The Gaqqee AS803 Digital Lux Meter is a high-precision illuminometer designed for accurate measurement of light intensity (illuminance) and ambient temperature. It is a compact, portable device suitable for a wide range of applications, from home and office environments to industrial inspection and agricultural research.

This manual provides detailed instructions for the safe and effective use of your AS803 Digital Lux Meter. Please read it thoroughly before operation.

Gaqqee AS803 Digital Lux Meter showing high precision measurement and key features

Figure 1: Gaqqee AS803 Digital Lux Meter with display showing lux and temperature readings.

2. Product Features

  • High Precision Measurement: Offers a wide measuring range of 1 to 200,000 lux with an accuracy of ±5%rdg ±10.
  • Ambient Temperature Measurement: Integrated temperature sensor accurately measures current ambient temperature in real-time.
  • Miniature and Compact Design: Easy to carry and operate, making it convenient for various applications.
  • Rotatable Probe: The light illumination probe can be rotated 180 degrees to the right for flexible measurement in different environments.
  • Backlit LCD Display: High-definition large screen with LED backlight ensures clear visibility even in dark conditions.
  • Data Hold Function: Allows locking of maximum and minimum measured values.
  • Unit Conversion: Easily switch between Lux and Fc (Foot-candle) measurement units.
  • Automatic Shutdown: Energy-saving feature automatically turns off the device after 3 minutes of inactivity.
  • Low Battery Indication: Alerts the user when batteries need replacement.
Play video
Watch video online

Video 1: Overview of the AS803 Digital Lux Meter's features and compact design.

3. Components Overview

Familiarize yourself with the different parts of your AS803 Digital Lux Meter:

Labeled diagram of AS803 Digital Lux Meter components

Figure 2: Labeled diagram of the AS803 Digital Lux Meter.

  1. Light Illumination Probe: Sensor for measuring light intensity.
  2. LCD Display Screen: Shows lux, temperature, and other indicators.
  3. Power On/Off Key: Turns the device on or off.
  4. Photometric Unit Conversion Key (LUX/FC): Switches between Lux and Foot-candle units.
  5. Mode Key: Used for various functions, including data hold (MAX/MIN).
  6. Backlight Control and Temperature Unit Keys (C/F): Controls the display backlight and switches between Celsius and Fahrenheit for temperature.

4. Setup

4.1. Battery Installation

The AS803 Digital Lux Meter requires 3 x 1.5V AAA batteries (not included) for operation.

  1. Locate the battery compartment cover on the back of the device.
  2. Slide the cover downwards to open the compartment.
  3. Insert three 1.5V AAA batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
  4. Close the battery compartment cover by sliding it back into place until it clicks securely.
Battery compartment of the AS803 Digital Lux Meter

Figure 3: Open battery compartment for installing AAA batteries.

Note: Ensure batteries are installed correctly. Remove batteries if the device will not be used for an extended period to prevent leakage.

5. Operating Instructions

5.1. Power On/Off

  • Press the Power On/Off Key (labeled with a power symbol) to turn the device on.
  • Press and hold the Power On/Off Key again to turn the device off.

5.2. Taking Measurements

  1. Turn on the device. The LCD display will show the current light intensity in Lux and ambient temperature.
  2. Point the light illumination probe towards the light source or area you wish to measure.
  3. For optimal readings, ensure the probe is positioned correctly. The sensor can be rotated 180 degrees to the right to adjust to the measuring environment.
Diagram showing the probe of the lux meter rotating 180 degrees

Figure 4: The probe can rotate 180 degrees to the right for flexible measurement.

5.3. Unit Conversion (Lux/Fc)

  • Press the LUX/FC Key to switch between Lux and Foot-candle units for light intensity measurement.

5.4. Data Hold (MAX/MIN)

  • Press the Mode Key to cycle through different display modes, including holding the maximum (MAX) or minimum (MIN) measured light intensity values.

5.5. Backlight Control

  • Press the Backlight Key (often combined with the C/F key) to turn the LCD backlight on or off for better visibility in low-light conditions.
AS803 display showing ambient temperature and LED backlight

Figure 5: The LED backlight ensures clear readings in various lighting conditions.

5.6. Temperature Unit Conversion (C/F)

  • Press the C/F Key (often combined with the backlight key) to switch the temperature display between Celsius (°C) and Fahrenheit (°F).

5.7. Automatic Shutdown

The device is designed to conserve battery life. If no operation is performed for approximately 3 minutes, the lux meter will automatically shut down. To resume operation, simply press the Power On/Off Key.

6. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Battery Replacement: Replace batteries when the low battery indicator appears on the display. Always use new 1.5V AAA batteries. If the device is not used for a long time, remove the batteries to prevent leakage.
  • Avoid Impact: Protect the device from strong impacts or drops, especially the light illumination probe.

7. Troubleshooting

  • Device does not turn on:
    • Check if batteries are installed correctly with the right polarity.
    • Replace with new batteries if the existing ones are depleted.
  • Inaccurate readings:
    • Ensure the light illumination probe is clean and unobstructed.
    • Verify that the measurement unit (Lux/Fc) is set correctly.
    • Ensure the device is within its operating environment temperature range (0°C to 40°C).
  • Display is dim or flickering:
    • This may indicate low battery. Replace batteries.
    • Ensure the backlight is activated if operating in dark conditions.

8. Specifications

Parameter Value
Model Number AS803
Brand Name Gaqqee
Measurement Range 1~200,000 lux
Measurement Accuracy ±5%rdg ±10
Unit Conversion Lux/Fc
Gear Selection Automatic
Data Hold Display Function Yes (Max/Min)
Automatic Switch-off Yes (after 3 minutes of no operation)
Low Battery Indication Yes
Repeatability ±2%
Operating Environment 0°C ~ 40°C
Sampling Frequency 2 times/second
Resolution 1 Lux * 0.1°C
Backlight Display Function Yes
Maximum and Minimum Value Lock Yes
Temperature Measurement Yes
Power Supply 3 * 1.5V AAA batteries (not included)
Weight About 0.100kg
Size 16.20cm x 4.70cm x 2.50cm
Certification CE

9. User Tips

  • For consistent readings, try to maintain the same distance and angle between the sensor and the light source during comparative measurements.
  • When measuring in very bright or very dim conditions, allow a few seconds for the sensor to stabilize for the most accurate reading.
  • The rotatable probe is useful for measuring light from various directions without having to reposition your body or the entire device. Remember it only rotates to the right.

10. Warranty and Support

For any questions, technical support, or issues with your Gaqqee AS803 Digital Lux Meter, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.

A digital version of this user manual is available for download. You can find it at the following URL: AS803 User Manual (PDF)

© 2023 Gaqqee. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.