Aideepen H56C Coulombmeter

Rate this product if you’ve used it
Contents

Aideepen H56C Coulombmeter User Manual

DC 9V-100V Battery Capacity Coulomb Meter Monitor

1. Introduction

The Aideepen H56C Coulombmeter is a high-precision battery gauge designed to accurately detect and display the voltage, current, power, real capacity, and remaining time of a battery pack. It provides real-time monitoring of the battery's working status.

1.1 Applicable Battery Specifications

This product is suitable for various types of batteries or battery packs with a voltage range of DC10-100V. This includes lithium batteries, lithium iron phosphate, lead-acid, nickel-hydrogen, and more. It is essential to use this product in conjunction with the matching Hall sensor.

2. Setup

2.1 Components Overview

The H56C Coulombmeter system consists of the main display unit and a Hall sensor. The display unit shows all relevant battery parameters, while the Hall sensor measures current without damaging the original wiring.

Aideepen H56C Coulombmeter and Hall Sensor
Figure 1: H56C Coulombmeter and Hall Sensor

2.2 Panel Description

The display panel provides a clear overview of all monitored parameters and control buttons.

H56C Coulombmeter Panel Description
Figure 2: H56C Coulombmeter Panel Description

  • Battery Icon: Visual representation of battery charge.
  • Remaining Time: Estimated time remaining for current operation.
  • Current Capacity (Ah): Displays the battery's current Amp-hour capacity.
  • Capacity Percentage: Shows the battery's charge level as a percentage.
  • Voltage (V): Real-time battery voltage.
  • Current (A): Real-time current flow (charging/discharging).
  • Power (W): Real-time power consumption/generation.
  • Up/Down Buttons: Used for navigation and adjusting settings.
  • Settings Button: Long press to enter the settings menu.

2.3 Wiring Method

Correct wiring is crucial for accurate measurements. Follow the diagram and instructions carefully.

Wiring Diagram for DC9-100V Hall Sensor
Figure 3: Wiring Diagram for DC9-100V Hall Sensor

  1. Hall Sensor Connection: The Hall sensor should be connected to the positive or negative bus circuit of the battery pack. Ensure the arrow direction on the sensor label aligns with the charging current direction of the battery pack.
  2. Coulombmeter Power Supply: Connect the red wire of the Coulombmeter to the positive pole of the battery pack and the black wire to the negative pole of the battery pack. These connections provide power to the Coulombmeter and enable voltage collection.
  3. Sensor to Meter Connection: Connect the Hall sensor to the Coulombmeter using the provided ribbon cable or a shielded wire. After connecting, power on the system and verify accuracy.
  4. Wiring Principle: The codes on the display and the Hall sensor must correspond one-to-one. All charging and discharging currents of the battery pack must pass through the Hall sensor for accurate measurement.

2.4 Installation Method

To install the Coulombmeter, process a rectangular hole in the panel where it will be mounted, according to the dimensions provided. Insert the monitor from the front and secure it with clamps.

Coulombmeter Installation Dimensions
Figure 4: Installation Dimensions (76.5mm x 39.5mm cutout)

3. Operating Instructions

3.1 First Use Method (Manual Mode)

When using the Coulombmeter for the first time, or after replacing a battery, you need to set parameters and perform a full charge cycle for accurate readings.

  1. Wiring and Current Check: After wiring, ensure the screen displays correctly. Charge and discharge the battery pack, verifying that displayed voltage and current values are close to actual values. If there's a significant deviation, recheck wiring. If the meter shows non-zero current when unloaded, reset it to zero (refer to item 15 in the settings menu).
  2. Set Parameters: It is recommended to correctly set the nominal capacity value (01CA) and full capacity voltage value (02FV).
    • Nominal Capacity (01CA): This refers to the actual full capacity of the battery pack.
    • Full Capacity Voltage (02FV): This refers to the highest virtual charge voltage when the battery pack is fully charged. If uncertain, charge the battery fully and set 02FV to the highest voltage displayed by the Coulombmeter before unplugging the charger.
  3. Capacity Reset: After setting parameters, fully charge the battery pack. The capacity should automatically display 100%. If the nominal capacity is known, after a full charge, press the ▲ (Up) key for about 2 seconds to manually fill it up to 100%. If the nominal capacity is unknown, discharge the battery completely, then press the ▼ (Down) key for about 2 seconds to manually reset to 0% capacity, then fully charge the battery. Once fully charged, set the displayed capacity value to 01CA.

3.2 Automatic Mode Usage

Automatic mode simplifies operation by not requiring manual setting of nominal capacity and full capacity voltage. The Coulombmeter determines full charge based on charging voltage and current changes.

  1. Wiring and Current Check: Same as manual mode.
  2. Change Charging Mode to Automatic: In the settings menu, change item 22AM to 'Automatic working mode A'.
  3. Battery Pack Capacity Clear Zero and Fully Charged:
    • Check if 01CA is 0. If not, modify it to 0.
    • Discharge the battery pack completely, then press the ▼ (Down) key for about 2 seconds to manually reset to 0% capacity.
    • Fully charge the battery pack. The capacity will automatically display 100%, and the current full capacity value (Ah) will be shown.

3.3 Using Settings Menu

The settings menu allows for customization of various parameters.

H56C Coulombmeter Settings Interface
Figure 5: H56C Coulombmeter Settings Interface

  • Entering Settings: Long press the Settings button for 3 seconds.
  • Selecting Cursor: Use the Up/Down buttons to move the cursor between settings.
  • Changing Values: Short press the Up or Down button for 1 second to modify the selected value or select a digit.
  • Entering Selected Setting: Long press the Settings button for 3 seconds to enter a specific setting.
  • Confirming Setting: Short press the Settings button for 1 second to save and exit.

3.4 General Operation Notes

  • The Coulombmeter must be in working condition to accurately calculate battery capacity.
  • During discharge, the current display value should be negative, and the backlight should be constantly on. A positive current value during discharge indicates a reversed Hall sensor direction, which needs adjustment.
  • In a quiescent state (current display is 0, no button operation), the backlight will turn off after about 30 seconds, and the meter will enter a low-power state. After 60 seconds, the screen display will turn off, entering a sleep state. The meter automatically wakes up if charging/discharging current is detected or a button is pressed.
  • The product has a power-off capacity memory function.
  • A certain error may occur in capacity calculation if the current changes drastically.

4. Maintenance

  • Environmental Conditions: Avoid exposing the product to direct sunlight for extended periods. Do not operate or store in extreme temperatures below -10°C or above 50°C, as this can shorten the LCD's lifespan.
  • Cleaning: Use a soft, dry cloth to clean the display and casing. Do not use abrasive cleaners or solvents.
  • Connection Integrity: Periodically check all wiring connections to ensure they are secure and free from corrosion.

5. Troubleshooting

  • Screen Not Displaying: Turn off power and carefully check all connection wires for correctness.
  • Inaccurate Voltage/Current Readings: Recheck the wiring, especially the Hall sensor connection. Ensure the main current wire passes through the Hall sensor hole in the correct direction as indicated by the arrow.
  • Non-Zero Current When Unloaded: If the Coulombmeter displays a non-zero current value when no load is connected, perform a current zero-spot calibration (refer to item 15 in the settings menu).
  • Capacity Not Reaching 100% After Full Charge: If the battery is fully charged but the meter doesn't show 100% capacity, it might be due to a special charging mode of your charger. You can manually set the capacity to 100% by pressing the ▲ (Up) button for about 2 seconds.
  • Capacity Deviation Over Time: Battery capacity can drift over long-term use. Perform a manual capacity zero-clearing or full-capacity setting as described in the 'Operating Instructions' section.
  • Incorrect Parameter Setting (e.g., 01CA): If you accidentally set an incorrect value (e.g., an extra zero in capacity), you can correct it manually in the settings menu. Alternatively, use the 'Restore default parameters' option (26DF) to reset all settings to factory defaults, then reconfigure.

6. Specifications

ParameterMin.RegularMax.Unit
Operating Voltage10.0-100V
Backlight On Power Consumption3.06.015.0mA
Backlight Off Working Power Consumption2.14.011.0mA
Sleep Power Consumption300400500uA
Accuracy of Voltage Collecting±1.0%
Accuracy of Current Collecting±1.0%
Accuracy of Capacity Collecting±1.0%
Capacity Detection Range0.1-9999Ah
50A Sampler Current0.05-50A
100A Sampler Current0.10-100A
200A Sampler Current0.20-200A
300A Sampler Current0.30-300A
400A Sampler Current0.50-500A
Temperature Range in Application Environment-102560℃
WeightNet weight: 95gGross weight: 110gg
H56C Size79 × 43 × 27mm

6.1 Additional Specifications

  • Display Type: Digital Only
  • DIY Supplies: Electrical
  • Accuracy Class: 0.1

7. User Tips

  • Read the Manual Thoroughly: This device requires careful setup and parameter configuration. Understanding the instructions is key to successful operation.
  • Hall Sensor Cable Extension: If extending the Hall sensor cable, use a shielded cable to maintain signal integrity and accuracy. One user successfully used an 8-way telephony cable with shielding for a 2.5m extension.
  • Double-Check Parameter Settings: Before saving, always verify that your entered values, especially for battery capacity (01CA), are correct to avoid errors.
  • Initial Calibration: For optimal accuracy, perform the initial capacity zero-clearing and full-capacity setting procedures as described in the 'Operating Instructions' section.

8. Warranty and Support

8.1 Warranty Information

This product comes with a one-year warranty from the date of purchase. During this period, repairs for non-human quality problems will be provided free of charge.8.2 Product Updates

The product may undergo technical improvements or updates. If there are any discrepancies between the physical product, its technical parameters, or this manual, please refer to the actual product or the official website for the most accurate information.

8.3 Additional Resources

A detailed user manual in PDF format is available for download: View User Manual (PDF)

9. Frequently Asked Questions (FAQ)

Q: Which model should I choose for a 200 amp 24 volts LiFePO4 battery?
A: You should choose the Coulombmeter model with a Hall sensor rated for 200A or higher to accurately measure the current of your 200 amp battery.
Q: Is it possible to use a longer cable for the Hall sensor?
A: Yes, it is possible to use a longer cable for the Hall sensor. However, to maintain accuracy and prevent interference, it is highly recommended to use a shielded cable for any extensions.
Q: How is the device programmed?
A: The device is programmed through its settings menu. Please refer to Section 3.3 'Using Settings Menu' and Section 9 'Parameter Settings' for detailed instructions on how to navigate and adjust parameters.
Q: Can this meter be installed on a test bench to monitor alternator parameters like voltage and amperage in real-time?
A: Yes, this meter is suitable for such applications. It can monitor voltage and amperage in real-time, provided the alternator's output voltage is within the DC9-100V range and the current is within the selected Hall sensor's rating.
Q: What is the diameter of the hole in the Hall sensor for passing the wire?
A: The exact diameter of the Hall sensor's pass-through hole is not specified in this manual. However, the sensor is designed to accommodate the main current wire for non-invasive current measurement.
Q: What do the three voltage parameters (02FV, 03ZV, 04OV) mean?
A: These refer to:
  • 02FV (Full Capacity Voltage): The voltage at which the battery is considered 100% charged.
  • 03ZV (Zero Capacity Voltage): The voltage at which the battery is considered 0% charged.
  • 04OV (Overvoltage Alarm): The voltage threshold above which an overvoltage alarm will be triggered.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?