Hi-Link URB2405LD-30WR3

Contents

Hi-Link URB2405LD-30WR3 30W DC/DC Switching Power Supply Module User Manual

Model: URB2405LD-30WR3

1. Introduction

The Hi-Link URB2405LD-30WR3 is a compact 30W DC/DC power module designed for various industrial applications. It features a 4:1 wide voltage input range, high conversion efficiency, and robust protection mechanisms. This manual provides essential information for the safe and effective use of the module.

This module is widely used in medical equipment, industrial control systems, electric power applications, instrumentation, communication devices, railway systems, and other fields requiring reliable isolated power conversion.

Front view of the URB2405LD-30WR3 DC/DC converter module

Figure 1: Front view of the URB2405LD-30WR3 DC/DC converter module.

2. Product Features

  • Ultra-wide input voltage range (4:1) with 30W output power.
  • High conversion efficiency: 91% (Typical).
  • Isolation voltage: 1500Vdc.
  • Ultra-low standby power consumption: 0.036W (Typical).
  • Ultra-fast startup time: 1mS (Typical).
  • Wide operating temperature range: -40°C to +85°C.
  • Comprehensive output protection: short circuit protection, over-current protection, over-voltage protection.
  • Durable metal case with low output ripple.
  • International standard pin configuration for PCB board in-line installation.
  • Sealed with high-quality environmental protection waterproof and thermal conductive glue, providing moisture-proof and vibration-proof properties, meeting IP65 requirements.
  • High reliability and long-life design for continuous operation.

3. Specifications

3.1. Typical Performance

  • Wide input voltage range (4:1), Output 30W
  • Conversion efficiency: 91% (Typ)
  • Isolation voltage: 1500Vdc
  • Ultra low power consumption: 0.036W (Typ)
  • Fast startup: 1ms (Typ)
  • Working temperature range: -40°C ~ +85°C
  • Input undervoltage, output short circuit, overcurrent, overvoltage protection
  • Metal case, low output ripple
  • International standard pins, PCB board in-line

The UR(A)B_LD-30WR3 series product output power is 30W, with a 4:1 wide voltage input range. It features an efficiency of up to 91% and a conventional isolation voltage of 1500VDC. The allowable operating temperature is -40°C to +85°C. It includes input under-voltage protection, output over-voltage, over-current, and short-circuit protection functions. The bare metal meets CISPR32/EN55032CLASSA standards.

3.2. Product Mode List

Below is a list of typical product models and their specifications. For models not listed, please refer to the full PDF manual for comprehensive details.

Product ModeInput Voltage Range (Vdc) Nominal (Range)Output Voltage (Vdc)Output Current (mA)(Max.)Ripple and Noise (mVp-p) (Typ./Max.)Maximum Capacitive Load (μF Max.)Efficiency @ full % (Min./Typ.)
URB2403LD-30WR324 (9~36)3.37000/030/501000086/88
URB2405LD-30WR356000/030/501000088/90
URB2412LD-30WR3122500/050/80160088/90
URB2415LD-30WR3152000/050/80100089/91
URB2424LD-30WR3241250/050/8050089/91
URA2405LD-30WR324 (9~36)±5±3000/030/50400084/86
URA2412LD-30WR3±12±1250/050/8080088/90
URA2415LD-30WR3±15±1000/050/8047089/91
URA2424LD-30WR324 (9~36)±24±625/050/8030087/89
URB4803LD-30WR348 (18-75)3.37000/030/50250080/82
URB4805LD-30WR356000/030/50220088/90
URB4812LD-30WR3122500/050/8068087/89
URB4815LD-30WR3152000/050/8047088/90
URB4824LD-30WR3241250/050/8047088/90
URA4805LD-30WR348 (18-75)±5±3000/030/50200084/86
URA4812LD-30WR3±12±1250/050/8080088/90
URA4815LD-30WR3±15±1000/050/8060088/90
URA4824LD-30WR348 (18-75)±24±625/050/8030087/89
URB1D03LD-30WR3110 (40-160)3.37000/030/501000085/87
URB1D05LD-30WR356000/030/501000086/88
URB1D12LD-30WR3122500/050/80220088/90
URB1D15LD-30WR3152000/050/80100089/91
URB1D24LD-30WR3241250/050/8047089/91
URA1D05LD-30WR3110 (40-160)±5±3000/030/50400084/86
URA1D12LD-30WR3±12±1250/050/80100088/90
URA1D15LD-30WR3±15±1000/050/8047089/91
URA1D24LD-30WR3110 (40-160)±24±625/050/8022089/91

Note: The maximum capacitive load indicates the maximum capacitive load that can be connected to +Vo or -Vo. If it exceeds this value, the product will not be able to start normally. Input voltage exceeding the maximum value may cause permanent damage to the product.

3.3. Input Characteristics

All parameter tests are measured at nominal input voltage, purely resistive rated load, and 25°C room temperature.

ItemsWorking ConditionsMin.Typ.Max.Unit
Input current (fully loaded / unloaded)24VDC nominal input series, nominal input voltage (3.3V)-1106/51132/15mA
24VDC nominal input series, nominal input voltage (5V)-1420/51453/15
24VDC nominal input series, nominal input voltage (12V)-1388/1.51420/2
24VDC nominal input series, nominal input voltage (15V)-1373/1.51404/2
24VDC nominal input series, nominal input voltage (24V)-1373/1.51404/2
Input current (fully loaded / unloaded)24VDC nominal input series, nominal input voltage (±5V)-1436/51470/15
24VDC nominal input series, nominal input voltage (±12V)-1388/1.51420/2
24VDC nominal input series, nominal input voltage (±15V)-1373/1.51404/2
Input current (fully loaded / unloaded)24VDC nominal input series, nominal input voltage (±24V)-1373/1.51404/2
48VDC nominal input series, nominal input voltage (3.3V)-553/0.8566/1
48VDC nominal input series, nominal input voltage (5V)-710/0.8726/1
48VDC nominal input series, nominal input voltage (12V)-694/0.8710/1

Additional input characteristics for 110VDC nominal input series are available in the full PDF manual.

3.4. Output Characteristics

ProjectWorking and test conditions+Vo1-Vo2
Min.Typ.Max.Min.Typ.Max.
Output loadLoad percentage0%-100%0%-100%
Output voltage accuracy--±1.0%±2.0%-±2.0%±3.0%
Linear adjustment rateInput voltage range-±0.2%±0.5%-±1.5%±2%
Load regulation20% ~ 100% rated load-±0.5%±1%-±4.0%±5.0%

3.5. General Characteristics

ItemsWorking conditionsMin.Typ.Max.Units
Insulation voltageInput-output, test time is 1 minute, leakage current is less than 1mA1500--VDC
Insulation resistanceInput-output, insulation voltage 500VDC1000--MΩ
Isolation capacitorInput-output, 100KHz/0.1V-1000-pF
Working temperatureUsing the Reference Temperature Derating Curve-40-+85°C
Storage temperature--40-+125°C
Max operating case---+100°C
Storage humidityno condensation5-95%RH
Pin SolderingSolder joint distance from shell 1.5mm, 10 seconds--+300°C
On-off levelPWM model-250-KHz
Vibration--10-55Hz, 10G, 30 Min. along X, Y and Z--
Shell material--Aluminum shell--
Minimum time between failuresMIL-HDBK-217F@25°C-2X105-Hrs

3.6. Package Size and Pin Function Diagram

Detailed package size and pin function diagram for the DC/DC converter module

Figure 2: Detailed package size and pin function diagram.

123456
Single(S)+Vin-VinCTRLTrim-Vo+Vo
Input+Input-Remote controlVoltage regulatorOutput-Output+
Dual(D)+Vin-VinCTRL-Vo2COM+Vo1
Input-Input-Remote controlOutput-2Common groundOutput+1

*Note: If the definition of each pin of the power module is inconsistent with the selection manual, the label on the physical label shall prevail.

3.7. Package Description

Package codeLxWxH (mm)LxWxH (inch)
B3S50.8X25.4X11.8mm2.000X1.000X0.464inch

4. Setup and Installation

All DC/DC converters in this series are tested according to the recommended test circuit before leaving the factory. For a visual representation of the circuit, please refer to the full PDF user manual, page 5.

General recommended capacitance values for the test circuit are: D1: 47-100 μF; C2, C3: 10-22μF. To further reduce input and output ripple, you can increase the input and output external capacitors D1, C2, C3 or choose a capacitor with a small series equivalent impedance. However, the capacitance value should not exceed the maximum capacitive load of the product.

For general ripple & noise requirements, it is recommended to use only C2 and C5 for the periphery. For strict ripple & noise requirements, the full circuit diagram is recommended. Please refer to the full PDF user manual, page 6, for detailed circuit diagrams.

Note: C2, C3, C5, C6 should be high-frequency low-resistance electrolytic capacitors. The total capacity should not exceed the maximum capacitive load specified in the manual, otherwise the module may not start normally. When capacitive load is used, a minimum load of 3% must be guaranteed, otherwise the module output will be abnormal. LDM5 is only used for dual output products.

Parameter Recommendation for Output Filter Peripheral:

Device code3.3V5V or ±5V±9V/12V±15V or 15V±24V or 24V
LDM3 inductance0.47μH1μH2.2μH2.2μH4.7μH
LDM4 inductance0.47μH1μH2.2μH2.2μH4.7μH
LDM5 inductance-1μH2.2μH2.2μH4.7μH
C2/C3 Electrolytic220μF220μF100μF100μF68μF
C4/C7 ceramic--1μF/50V--

4.3. Trim Function

The module includes a Trim pin for voltage regulation. The calculation formula for Trim resistance is provided in the full PDF manual, page 7. The Trim resistance (RT) is a custom parameter without substantive meaning.

Vout(V)R1(KΩ)R2(KΩ)R3(KΩ)Vref(V)
3.33018.26184.51.25
545.314.77884.51.25
93011.44184.52.5
125614.57184.52.5
155611.21884.52.5
2484.59.79184.52.5

4.4. Remote Control (CTRL)

The CTRL pin allows for remote control of the module. When the module is open, the CTRL pin can be floating or connected to TTL high level. When the module is closed, the CTRL pin should be connected to GND or low level. The input current at shutdown is typically 0-1 mA.

5. Operating Instructions

5.1. Power Connection

Connect the input power supply to the +Vin and -Vin pins. Ensure the input voltage is within the specified range (e.g., 9-36VDC for 24V nominal input models). Connect the load to the +Vo and -Vo pins (or +Vo1, -Vo2, COM for dual output models).

Caution: Input voltage exceeding the maximum specified value may cause permanent damage to the product.

5.2. Ripple & Noise Test Procedure

To accurately measure ripple and noise, follow these steps. For a visual diagram of the test setup, please refer to the full PDF user manual, page 7.

  1. Connect the ripple noise using a 12# twisted pair cable.
  2. Set the oscilloscope bandwidth to 20MHz and the probe bandwidth to 100M.
  3. Connect a 0.1uF polypropylene capacitor and a 47uF high-frequency low-resistance electrolytic capacitor in parallel at the probe end.
  4. Use the Sample sampling mode on the oscilloscope.
  5. Connect the power input terminal to the input power supply.
  6. Connect the power output to the electronic load through the fixture board.
  7. Use a 30cm ± 2cm sampling line to directly sample from the power output port.
  8. Select the power line with the insulation sheath of the corresponding wire diameter according to the magnitude of the output current.
Pin Diagram of the DC/DC Converter Module

Figure 3: Pin Diagram of the DC/DC Converter Module.

6. Maintenance

The URB2405LD-30WR3 module is designed for high reliability and long life. It is sealed with environmental protection waterproof and thermal conductive glue, providing moisture-proof and vibration-proof properties, meeting IP65 requirements. Regular maintenance is generally not required under normal operating conditions.

  • Environmental Conditions: Ensure the module operates within the specified temperature range of -40°C to +85°C. Avoid exposing the module to temperatures outside this range. Refer to the Temperature Derating Curve for performance at different temperatures.
  • Cleaning: If necessary, gently clean the exterior of the module with a dry, soft cloth. Do not use liquids or abrasive cleaners.
  • Inspection: Periodically inspect the module for any signs of physical damage, loose connections, or discoloration. Address any issues promptly.
  • Storage: When not in use, store the module in a dry environment with no condensation, at a temperature between -40°C and +125°C, and humidity between 5% and 95% RH.

7. Troubleshooting

  • Module Fails to Start:
    • Check if the input voltage is within the specified range.
    • Verify that the capacitive load connected to the output does not exceed the maximum capacitive load specified in the product mode list. Exceeding this value will prevent the module from starting normally.
  • Abnormal Output:
    • If a capacitive load is used, ensure a minimum load of 3% is guaranteed. Failure to do so may result in abnormal output.
    • Check for output short circuit, overcurrent, or overvoltage conditions. The module has built-in protection, but persistent issues may indicate an external problem or a fault in the module.
  • Excessive Ripple & Noise:
    • Review the EMC Solutions and Recommended Test Circuit sections.
    • Consider increasing the input and output external capacitors (D1, C2, C3) or using capacitors with a small series equivalent impedance.
    • Ensure the ripple & noise test is performed using the twisted pair method with appropriate oscilloscope settings.
  • Module Overheating:
    • Ensure the ambient operating temperature is within the specified range (-40°C to +85°C).
    • Verify that the load is not exceeding the module's rated power. Refer to the Temperature Derating Curve for performance at different temperatures.

8. User Tips

  • Always double-check input and output polarities before connecting to prevent damage.
  • When designing your circuit, pay close attention to the recommended external components for EMC filtering to ensure stable operation and compliance.
  • For applications with varying loads, ensure the minimum load requirement is met, especially when using capacitive loads, to avoid output abnormalities.
  • Consider the thermal environment. While the module has a wide operating temperature range, proper ventilation or heat sinking can extend its lifespan, especially when operating at higher loads or ambient temperatures.

9. Warranty and Support

For technical support, inquiries, or warranty information, please contact Shenzhen Hi-Link Electronic Co., Ltd using the details below:

Shenzhen Hi-Link Electronic Co., Ltd
Add: Room 301, Building 1, 1970 Science & Technology Park, Minzhi Community, Minzhi Street, Longhua District, Shenzhen
Web: www.hlktech.com
Email: sales@hlktech.com
Tel: 0755-23152658

A user manual in PDF format is also available for download: Download User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.