FOORIR HX-CCD22

Contents

FOORIR HX-CCD22 3D People Counter Camera User Manual

Model: HX-CCD22 | Brand: FOORIR

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the FOORIR HX-CCD22 3D People Counter Camera. This device is specifically designed for accurate people counting in bus environments, featuring night vision capabilities.

Video: Animation demonstrating the FOORIR HX-CCD22 people counting functionality in a bus, showing real-time updates for people getting on, getting off, and current occupancy.

For a downloadable PDF version of this manual, please refer to the official user manual PDF.

2. Safety Information

  • The housing is prohibited from being disassembled during operation.
  • Be careful when manually disassembling the housing of the device to avoid damage.
  • This is a Class A product. In a living environment, this product may cause radio interference. In this case, the user may need to take practical measures to deal with the interference.

3. Product Overview

3.1 Packing List

Ensure all items are present and undamaged upon unboxing. If any items are damaged or lost, contact your supplier.

FOORIR HX-CCD22 Packing List and Interface Display
Image: Interface display and packing list for the HX-CCD22. Includes the camera, screws, waterproof cap, I/O and 485 connectors, power connector, instructions, inner hexagon spanner, bracket, and power adapter.

The packing list includes:

  • HX-CCD22 Camera Unit
  • Waterproof Cap
  • Screws
  • I/O and 485 Connectors
  • Power Connector
  • Instructions Manual
  • Inner Hexagon Spanner
  • Bracket
  • Power Adapter

3.2 Product Size

Unit: mm

FOORIR HX-CCD22 Product Dimensions
Image: Diagram showing the dimensions of the HX-CCD22 camera. Front view: 143mm width, 70mm height. Side view: 40mm depth.
  • Width: 143 mm
  • Height: 70 mm
  • Depth: 40 mm

3.3 Appearance and Function

FOORIR HX-CCD22 Front and Back View
Image: Front view of the HX-CCD22 showing binocular cameras, fill light, and status indicators (P, S, L). Back view shows power interface, RS485&DI/DO port, DC power supply, and Ethernet port.
Name Description
Power Light 1. On: Power supply is normal;
2. Off: No power supply;
Status Light 1. Always on: device working normally, public network connection normal;
2. Long on, short off (3s on, 1s off): device working normally, public network connection abnormal;
3. Fast flashing (blink twice, off 1s): connecting to Wi-Fi;
4. Slow flashing (blink once, off 1s): device in debugging mode (Wi-Fi mode network cable connected), network cable not connected, Wi-Fi connection timeout.
Wired Network Connection Indicator 1. Flashing/steady on: Wired network cable connected normally;
2. Off: Network cable not connected correctly;
RS485&DI/DO Port Port 1: 485A, Port 2: 485B;
Port 3&4: DI and DO interfaces.
Attention: For port 1234, refer to numbers on the interface.
Ethernet Interface RJ45 interface/PoE port
Power Interface 3.5mm-2Pin power interface (9-36V)
DC Power Supply 5.5-2.1 Power interface (9-36V)

4. Installation Instructions

4.1 Installation Notes

  • Refer to the height coverage table before installation and select a height that can fully cover the installation area.
  • The installation height needs to be as accurate as possible, with an error of less than 5cm.
  • The device must be installed horizontally and does not support tilted installation.
  • The lens cannot be blocked by objects.
  • The brightness of the ambient light can impact device statistics.

4.2 Installation Height and Coverage

It is recommended to find an installation location at a suitable height based on the required coverage.

The detection area needs to be set according to the actual environment and should only cover the ground channel.

Installation Height (m) Coverage Width (m)
1.91.1
2.01.65
2.12.2
2.22.75
2.33.3
2.43.85
2.54.4
2.64.95
2.75.49
2.86.04
2.96.59
3.07.14
3.17.69
3.28.24

Note: The bus version supports the highest height.

4.3 Factors Affecting Accuracy

  • The detection line should only cover the ground and not other higher objects.
  • The height should be consistent with the actual installation height. A greater difference will result in lower accuracy.
  • If the detection area is too large and the environment is complex, accuracy may be affected.
  • Significant changes in ambient light can affect accuracy.
  • Objects blocking people as they enter and exit can interfere with counting.

4.4 Installation Steps

FOORIR HX-CCD22 Installation Examples
Image: Examples of top-mounted, wall-mounted, and embedded installations of the HX-CCD22 camera in a bus.

Ceiling Installation

  1. Mark the installation position of the bracket.
  2. Drill installation holes using an electric drill.
  3. Fix the expansion screw slots into the holes on the ceiling.
  4. Install the bracket firmly with the expansion screws.
  5. Embed the device into the bracket.
  6. Align the holes on the side of the bracket with the screw holes on the device.
  7. Fix the device with the standard 304 cylindrical head hexagon screws.
  8. Supply power to the equipment and the grid.

5. Device Connection and Startup

5.1 Device Powered On

The HX-CCD22 supports two power supply methods:

1. DC: 9-36V Power Supply

Plug the standard DC 12V power adapter into a 220V power supply and connect the 12V output harness terminals to the camera's 12V power supply port.

2. PoE Power Supply

If PoE switch connection conditions are available, the device can be directly connected to a PoE switch. This provides both power and networking simultaneously, eliminating the need for a separate DC power supply.

FOORIR HX-CCD22 Operating Principle Diagram
Image: Diagram illustrating the operating principle, showing two people counting cameras connected to an on-board host (4G+GPS), which then connects to a local client and a Bus Passenger Counting System Platform via the internet.

5.2 Connect Devices Using Hotspot

  1. Open the Wi-Fi list on your computer or phone.
  2. Search for the device's hotspot: "HF + the last 10 digits of the SN".
  3. The default hotspot password is: hf123456.
  4. Open any browser and enter the access address: 192.168.4.10.
  5. The default username is: admin.
  6. The default password is: hf123456.

5.3 Connect the Device Using a Network Cable

  1. Download the accompanying tool "foorir-search" by scanning the QR code or from the official website www.foorir.com.
  2. Open the supporting tool and scan for devices.
  3. After searching for the device, enter the device configuration page.

6. Device Configuration Page Operations

Before setting parameters, counting must be stopped.

6.1 Accessing Settings

Go to the device homepage and select the "Settings" option.

6.2 Set the Height Parameter

  • Settings are based on the actual installation type (top mounting, side mounting, angled mounting). Top-mounted horizontal installation is recommended.
  • Installation Height: The entered height must match the actual installation height (error less than ±5cm).
  • Filter Height: Objects below this height will not be detected. This effectively filters interference. A height of 100-120cm is recommended.
  • Installation Angle: The optimal installation method is horizontal with a 0-degree angle. Inclined installation is not recommended.
  • Child Mode: When enabled, people below the child height but above the filter height will be counted as children. If the child height setting is equal to the filter height, it will be ineffective.

6.3 Set Detection Area and Detection Line

  • Before setting parameters, you need to stop counting.
  • Before setting, update the background image to ensure the lens is unobstructed.
  • Detection Area: Blue represents the maximum detection range at the current height, and red represents the current actual detection range. The detection range cannot exceed the ground area and can be drawn according to the actual ground passage area.
  • Detection Line: The detection line should not be too close to one side of the detection area, and should be centered as much as possible. When setting, ensure that each entry and exit passes through the middle detection line. If sides of the detection line are missed, turn on broken line mode.
  • Detection Direction: The direction indicated by the arrow is the entrance direction.

6.4 Network Settings (Optional)

  • It is not recommended to use wired and wireless networks simultaneously unless specific needs dictate.
  • It is advisable to use the default wired DHCP mode.
  • If manually setting a static IP address, ensure it is correct, usable, and avoids conflicts.
  • The wireless network device only supports 2.4GHz WiFi. It cannot connect to 5GHz or mixed-frequency WiFi.
  • After network setup, the device will restart (approx. 1-2 minutes). Wait for it to restart completely before refreshing the page.

6.5 Data Reporting Settings (Optional)

The device supports data reporting via HTTP, FTP, and MQTT. HTTP reporting is recommended.

  • For HTTP: Only fill in the server address and port.
  • For FOORIR cloud platform: Set server address to op.foorir.com; port: 8088.
  • For other settings, click on Interface Settings and Advanced Settings.
FOORIR HX-CCD22 Statistical Report Interface
Image: Examples of statistical reports generated by the HX-CCD22, including real-time vehicle reports and data overview reports showing passenger flow data.

6.6 Equipment Upgrade (Optional)

Firmware upgrades are usually not required. If notified by the supplier, upload the provided firmware here to upgrade the device. Confirm the device's version number before and after the upgrade to verify success.

6.7 Map Collection (Optional)

If the count is inaccurate, you can click this button to automatically download the data collected that day and submit it to the manufacturer for algorithm optimization.

7. Maintenance

  • The device automatically restarts at midnight every day by default. Local video display data is cleared after restart, but local storage data is not cleared.
  • The heat dissipation of the device is on the back. If installed outdoors, it is recommended to add a baffle above the device to avoid direct sunlight.
  • Try not to have obstructions within the field of view of the lens.
  • Wired connections take precedence over wireless connections. After configuring wireless mode, unplug the network cable.
  • WiFi only supports 2.4GHz, not 5GHz.
  • Network latency affects the device's connection to the client.
  • The installation height and angle must be filled in according to the actual one. Incorrect height or angle will lead to inaccurate counting.
  • When setting the height, ensure no people or objects are under the camera other than the background.

8. Troubleshooting

8.1 Device Cannot be Found in Wired Mode

  • Solution 1: Connect the computer and the device to the same LAN or connect with a network cable, and change the IP address of the computer to DHCP.
  • Solution 2: Check the IP of the passenger flow device according to the network device (e.g., router), change the computer to the same network segment, and manually enter the IP connection.

9. Specifications

Attribute Value
Brand NameFOORIR
Model NumberHX-CCD22
Type8-digit Counters
DIY SuppliesElectrical
OriginMainland China
CertificationCE, FCC, RoHS
Battery IncludedYes
High-concerned chemicalNone
View angleHorizontal 140°, Vertical 120°
Size (approx.)143mm (W) x 70mm (H) x 40mm (D)
MaterialMetal and plastic
Power supplyDC12V/POE
Accuracy≥98%
Height range1.9~3.2m
Coverage area1.1~8.24m
Filter height0.5~1.2m
Power3.2W~7.2W

10. User Tips

Based on common user inquiries and operational best practices:

  • Always ensure the installation height is accurately measured and entered into the system for optimal counting accuracy.
  • Keep the camera lens clear of any obstructions to prevent interference with detection.
  • When configuring network settings, prioritize wired connections for stability, and remember to unplug the network cable if switching to wireless after initial setup.
  • For outdoor installations, consider adding a protective baffle above the device to shield it from direct sunlight and aid in heat dissipation.
  • If counting accuracy is consistently low, utilize the "Map Collection" feature to send data to the manufacturer for algorithm optimization.

11. Warranty and Support

Manufacturer: Chengdu Huaxin Zhiyun Technology Co., Ltd.

Contact Information:

  • Phone/WhatsApp: +86 18981978865
  • E-mail: info@foorir.com
  • Website: www.foorir.com
  • Address: Room 4021, Unit 1, Building 1, 88 Tianchen Road, High-Tech Zone, Chengdu, Sichuan, China

For any issues, shortages, or damage to accessories, please contact your local dealer or the manufacturer directly.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.