SNDWAY SW-DR60 SW-DR100

Contents

SNDWAY Dual Laser Distance Meter

Models: SW-DR60, SW-DR100

User Manual

1. Safety Regulations

Please read the safety regulations and operation guide carefully before operating.

  • Please read all of the operational guide and safety regulations in this manual before operation. Improper operations without complying with this manual may cause damage to the device, influence on measurement result or cause personal injury to the user or a third party.
  • The instrument is not allowed to disassemble or repair in any ways. It is forbidden to do any illegal modification or performance change for laser emitter. Please keep it out of reach of children and avoid being used by any irrelevant person.
  • It is strictly prohibited to shoot eyes or other parts of body with the laser. It is not allowed to take the laser to shoot the surface of any highly reflective objects.
  • Due to electromagnetic radiation interference to other equipment and devices, please don't use the meter in the plane or around medical equipment, don't use it in inflammable, explosive environment.
  • Discarded meter device should not be processed just like household garbage, please handle it in line with related law and regulations.
  • Any quality issues or any questions on the meter, please contact local distributors or manufacturer in time, we are ready to offer solutions for you.

2. Product Overview

The SNDWAY Dual Laser Distance Meter is a versatile tool designed for accurate distance, area, volume, and angle measurements. It features a clear display, intuitive controls, and robust construction for various applications.

SNDWAY Dual Laser Distance Meter with green laser beam

Figure 2.1: SNDWAY Dual Laser Distance Meter (SW-DG60 model shown)

2.1. Screen and Keys

The device features a comprehensive display and easy-to-use buttons for all functions.

Diagram of SNDWAY Laser Distance Meter showing screen indications and button functions

Figure 2.2: Screen Indications and Key Functions

Screen Indications:

  • Screen lock indication: Shows if the screen orientation is locked.
  • Measuring mode: Displays the current measurement function (e.g., length, area).
  • Angle indication: Shows the current tilt angle.
  • Laser indication: Indicates if the laser is active.
  • Measuring reference indication: Shows the current measurement starting point (front, rear, or center).
  • Battery level indication: Displays remaining battery charge.
  • Main display area: Shows primary measurement results.
  • Auxiliary display area: Shows secondary information or previous measurements.
  • Unit: Displays the current unit of measurement (e.g., m, ft, in).
  • Level bubble: Electronic level indicator.

Key Functions:

  • Power-on / Measure: Turns the device on and initiates measurements.
  • Add/Subtract / Lock screen: Adds or subtracts measurements, and locks/unlocks screen orientation.
  • Power-off / Clear: Turns the device off and clears current measurements.
  • Unit / Measuring reference: Changes measurement units and sets the measurement reference point.
  • FUN RECORD (Function / Record): Selects different measurement functions and accesses measurement records.

3. Setup

3.1. Charging the Device

Before first use, ensure the device is fully charged. A low battery indicator will appear on the screen when charging is needed.

  • Use a compliant charger with DC5V ≥1A output. Standard phone chargers are recommended.
  • Connect the Type-C charging cable to the device and a power source.
  • During charging, the battery icon will flash. Once fully charged, the battery icon will be solid.
  • Charging time is approximately 1.5 hours.
SNDWAY Laser Distance Meter with charging cable and accessories

Figure 3.1: Device with included charging cable and accessories

4. Operating Instructions

4.1. Power On/Off

  • Power On: In the off state, long press the MEAS button for 3 seconds. The instrument will power on and enter the test mode.
  • Power Off: In the on state, long press the OFF/CLEAR button for 3 seconds. The instrument will power off. If no operation is performed within 180 seconds, the instrument will shut down automatically.

4.2. Unit Setting

In length measuring mode, long press the UNIT button to enter the measuring units page. The instrument provides 6 optional units:

#LengthAreaVolume
10.000 m0.000 m²0.000 m³
20.00 m0.00 m²0.00 m³
30.0 in0.00 ft²0.00 ft³
40'1/16 in0.00 ft²0.00 ft³
50'00" 1/160.00 ft²0.00 ft³
60.00 ft0.00 ft²0.00 ft³

4.3. Measurement Reference

Press the UNIT button to set the measurement reference. The default benchmark is bidirectional measurement.

  • Left-forward datum: Measurement starts from the front edge of the device.
  • Left-back datum: Measurement starts from the rear edge of the device.
  • Right-back datum: Measurement starts from the rear edge of the device (for specific models/modes).
  • Bidirectional measurement: Measurement is taken from the center of the device, extending in both directions.

4.4. Measurement Modes

Press the FUN RECORD button to enter mode selection. The instrument provides 9 optional modes:

IconModeIconMode
──Length mode△Calculate height by measuring angle
□Area mode△Calculate height of right triangle
■Volume mode△Calculate hypotenuse of right triangle
▢Wall area mode△Calculate the sum of the sides of triangle
△Calculate the auxiliary height of right triangle

To navigate modes: Press ADD/SUBTRACT to switch mode, press MEAS to select mode, and press OFF/CLEAR to return.

4.5. Screen Rotation and Lock

The instrument supports automatic screen rotation for easy viewing in any orientation. To lock the screen direction, long press the ADD/SUBTRACT button. A lock icon will appear on the screen. Long press ADD/SUBTRACT again to unlock the screen orientation.

Diagram showing automatic screen rotation and lock feature of the laser distance meter

Figure 4.1: Automatic Screen Rotation and Lock

4.6. Electronic Level Bubble

The instrument is equipped with an electronic level bubble to measure the levelness of a plane, providing more accurate and efficient results.

SNDWAY Laser Distance Meter displaying electronic level bubble on screen

Figure 4.2: Electronic Level Bubble in action

4.7. Angle Measuring

The instrument has a built-in tilt sensor, which can measure the angle of both sides of the bottom and side edges in real-time.

SNDWAY Laser Distance Meter displaying angle measurement of 45 degrees

Figure 4.3: Electronic Angle Sensor measuring 45 degrees

4.8. Distance, Area, Volume, and Pythagorean Measurements

4.8.1. Length Mode - Single Measurement

In length mode, press MEAS to emit the laser and lock the measuring point. Press MEAS again for a single distance measurement. Results are shown in the main display. For bidirectional measurements, the auxiliary display shows distances from both ends.

4.8.2. Length Mode - Continuous Measurement

Long press MEAS in length mode to enter continuous measurement. The screen displays real-time data, maximum, and minimum values. Press MEAS or OFF/CLEAR to exit.

4.8.3. Midpoint Finding

Set the reference to bidirectional. Long press MEAS to start continuous measurement. Follow on-screen arrows (left/right for landscape, up/down for portrait) to locate the midpoint. When both arrows appear, the device is at the midpoint.

SNDWAY Laser Distance Meter showing center point positioning with bidirectional measurement

Figure 4.4: Center Point Positioning

4.8.4. Area Measurement

Press MEAS to measure the first side (length), then press MEAS again for the second side (width). The auxiliary display shows length and width. Press OFF/CLEAR to clear and remeasure.

4.8.5. Volume Measurement

Press MEAS for length, then width, then height. The instrument calculates volume automatically. Auxiliary display shows length, width, and height. Press OFF/CLEAR to clear and remeasure.

4.8.6. Wall Area Measurement

Press MEAS for wall height, then for width 1. The device calculates area (height x width 1). Continue for width 2, etc. The device sums total wall area.

4.8.7. Pythagorean Measurement (Indirect Measurement)

This mode is used for indirect measurements based on the Pythagorean theorem. Follow on-screen prompts to measure sides in the correct order (hypotenuse first, then legs). Ensure the hypotenuse is longer than the legs to avoid errors.

  • Calculate height by measuring angle: Measure hypotenuse (a), device measures angle, calculates horizontal (b) and vertical (h) distances.
  • Calculate height of right triangle: Measure hypotenuse (a), then right angle side (b), device calculates height (h).
  • Calculate hypotenuse of right triangle: Measure one side (a), then right angle side (b), device calculates hypotenuse (x).
  • Calculate sum of sides of triangle: Measure hypotenuse (a), another hypotenuse (b), then leg (c), device calculates height (x).
  • Calculate auxiliary height of right triangle: Measure hypotenuse (a), side (b), then other hypotenuse (c), device calculates auxiliary height (x).

4.9. Addition and Subtraction Measurement

This function allows you to add or subtract multiple measurements (length, area, volume).

  • To Add: After a measurement, short press ADD/SUBTRACT. A "+" sign will appear. Perform the next measurement, and the device will automatically add it.
  • To Subtract: After a measurement, short press ADD/SUBTRACT twice. A "-" sign will appear. Perform the next measurement, and the device will automatically subtract it.

You can continue adding or subtracting multiple measurements. The final result will be displayed after the last operation.

5. Maintenance

  • Storage: It is forbidden to store the instrument in a high temperature and humid environment for a long time. When the instrument is not used for a long time, please put the instrument in a cloth box and store it in a dry and cool place.
  • Cleaning: Please keep the surface of the instrument clean. User can wipe the dust with a damp soft cloth. Do not clean the instrument with corrosive liquid. The laser window and focusing mirror can be wiped in the same way as optical devices.
  • Battery Care: If not used for a long time, it is recommended to fully charge the instrument and charge it once every six months to avoid battery discharge damage.

6. Troubleshooting

During use, the following prompt information may be displayed in the main display area:

InfoCauseSolution
ErrOut of measuring rangeUse the instrument within the measurement range
Err1Weak signalMeasure the target point with strong reflectivity
Err2Strong signalMeasure the target point with weak reflectivity
Err3Low battery voltageCharge the battery
Err4Out of operating temperature rangeUse the instrument in the specified environment
Err5Wrong Pythagorean measurementRemeasure, ensure the hypotenuse is longer than the right side
Err6Angle sensor failureReturn to factory for repair

7. Specifications

ItemSW-DR60SW-DR100
Measuring range60m (Unidirectional), 120m (Bidirectional)100m (Unidirectional), 200m (Bidirectional)
Accuracy±(2mm + D*1/10000)* (Unidirectional)
Dip measuring range±90°
Continuous measurement✓
Area/Volume measurement✓
Wall area measurement✓
Pythagorean measurement✓
Angle and height measurement✓
Length addition/subtraction measurement✓
Max/Min value✓
Electronic level bubble✓
Automatic screen rotation✓
Magnetism✓
Laser levelII
Laser type630-670nm, <1mW
Max storage100 units
Auto laser-off20s
Auto power-off180s
Backlight time60s
Battery3.7V 850mAh Li-ion
Charge timeAbout 1.5 hours
Charging specificationDC5V 0.75A Type-C
Operation times at full charge8000 times (Unidirectional); 5000 times (Bidirectional)8000 times (Unidirectional); 5000 times (Bidirectional)
Storage temperature-20°C ~ 60°C
Working temperature0°C ~ 40°C
Storage humidity20% ~ 80% RH
Dimension115x50x24.5mm

* "D" indicates the actual distance.

** In harsh environments (strong sunlight, extreme temperature fluctuations, weak reflection, low battery), measurement results may have larger errors. A reflecting plate is recommended in such conditions.

8. User Tips

  • Accuracy: For critical measurements, especially with dual laser mode, be aware of potential variations (up to 3mm). For single laser measurements from an edge, expect higher precision (1-2mm).
  • Unit Selection: The device supports various units including meters, feet, and inches (e.g., 0.0 in, 0'00" 1/16, 0.00 ft). Ensure you select the appropriate unit for your task via the Unit Setting menu.
  • Environmental Conditions: For best accuracy, avoid strong sunlight, extreme temperature fluctuations, and measure against highly reflective surfaces. Using a reflecting plate can improve accuracy in challenging conditions.

9. Packing List

Please check carefully whether all accessories are complete according to the following list:

ItemNameUnitQTYNote
1MeterPC1
2PouchPC1
3StrapPC1
4User manualPC1
5Color boxPC1
6Type-C cablePC1
7ReflectorPC1Just available for 100m models

Product Demonstration

Video 1: Official product demonstration showcasing features and usage scenarios.

10. Warranty and Support

For any quality issues, questions, or support regarding your SNDWAY Dual Laser Distance Meter, please contact us:

  • Manufacturer: Sndway Technology (Guangdong) Co., LTD
  • Address: Sndway Science & Technology Industrial Park, 58 Tuanjie Road, Humen 523930, Dongguan, China
  • Service Hotline: 400-125-6969
  • Tel: 0769-85265688
  • Website: www.sndway.com
  • E-mail: market@sndway.com

Please retain your purchase receipt for warranty claims.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.