1. Product Overview
The Hi-Link 30W DC-DC power module series offers compact, high-efficiency (up to 91%) converters with a 4:1 wide voltage input range. These modules feature 1500VDC conventional isolation voltage and are designed for robust performance across various applications.
Key features include:
- Ultra-wide input voltage range (4:1)
- Output power: 30W
- High conversion efficiency: 91% (Typical)
- Isolation voltage: 1500VDC
- Ultra-low standby power consumption: 0.036W (Typical)
- Fast startup: 1mS (Typical)
- Wide operating temperature range: -40°C to +85°C
- Comprehensive output protection: short circuit, over-current, and over-voltage protection
- Metal case for low output ripple
- International standard pins, suitable for PCB board in-line installation
- Sealed with high-quality environmental protection waterproof and thermal conductive glue, providing moisture-proof and vibration-proof properties, meeting IP65 requirements.
- High reliability and long continuous working time.

2. Specifications
2.1. Product Mode List
| Product Mode | Input Voltage Range (Vdc) | Output Voltage (Vdc) | Output Current (mA)(Max.) | Ripple and Noise (mVp-p) (Typ./Max.) | Maximum Capacitive Load (μF Max.) | Efficiency %(Min./Typ.) |
|---|---|---|---|---|---|---|
| URB2403LD-30WR3 | 24 (9~36) | 3.3 | 7000/0 | 30/50 | 10000 | 86/88 |
| URB2405LD-30WR3 | 5 | 6000/0 | 30/50 | 10000 | 88/90 | |
| URB2412LD-30WR3 | 12 | 2500/0 | 50/80 | 1600 | 88/90 | |
| URB2415LD-30WR3 | 15 | 2000/0 | 50/80 | 1000 | 89/91 | |
| URB2424LD-30WR3 | 24 | 1250/0 | 50/80 | 500 | 89/91 | |
| URA2405LD-30WR3 | 24 (9~36) | ±5 | ±3000/0 | 30/50 | 2000 | 85/87 |
| URA2412LD-30WR3 | ±12 | ±1250/0 | 50/80 | 800 | 88/90 | |
| URA2415LD-30WR3 | ±15 | ±1000/0 | 50/80 | 600 | 88/90 | |
| URA2424LD-30WR3 | ±24 | ±625/0 | 50/80 | 300 | 87/89 | |
| URB4803LD-30WR3 | 48 (18~75) | 3.3 | 7000/0 | 30/50 | 2500 | 80/82 |
| URB4805LD-30WR3 | 5 | 6000/0 | 30/50 | 2200 | 88/90 | |
| URB4812LD-30WR3 | 12 | 2500/0 | 50/80 | 680 | 87/89 | |
| URB4815LD-30WR3 | 15 | 2000/0 | 50/80 | 470 | 88/90 | |
| URB4824LD-30WR3 | 24 | 1250/0 | 50/80 | 470 | 88/90 | |
| URA4805LD-30WR3 | 48 (18~75) | ±5 | ±3000/0 | 30/50 | 2000 | 84/86 |
| URA4812LD-30WR3 | ±12 | ±1250/0 | 50/80 | 800 | 88/90 | |
| URA4815LD-30WR3 | ±15 | ±1000/0 | 50/80 | 470 | 88/90 | |
| URA4824LD-30WR3 | ±24 | ±625/0 | 50/80 | 300 | 87/89 | |
| URB1D03LD-30WR3 | 110 (40~160) | 3.3 | 7000/0 | 30/50 | 10000 | 85/87 |
| URB1D05LD-30WR3 | 5 | 6000/0 | 30/50 | 10000 | 86/88 | |
| URB1D12LD-30WR3 | 12 | 2500/0 | 50/80 | 2200 | 88/90 | |
| URB1D15LD-30WR3 | 15 | 2000/0 | 50/80 | 1000 | 89/91 | |
| URB1D24LD-30WR3 | 24 | 1250/0 | 50/80 | 470 | 89/91 | |
| URA1D05LD-30WR3 | 110 (40~160) | ±5 | ±3000/0 | 30/50 | 4000 | 84/86 |
| URA1D12LD-30WR3 | ±12 | ±1250/0 | 50/80 | 1000 | 88/90 | |
| URA1D15LD-30WR3 | ±15 | ±1000/0 | 50/80 | 470 | 89/91 | |
| URA1D24LD-30WR3 | ±24 | ±625/0 | 50/80 | 220 | 89/91 |
Note: Due to limited space, this list is typical. For other products, please contact the sales department. The maximum capacitive load must not be exceeded, or the product may not start normally. Input voltage exceeding the maximum value may cause permanent damage.
2.2. General Characteristics
| Item | Working Conditions | Min. | Typ. | Max. | Units | |
|---|---|---|---|---|---|---|
| Insulation Voltage | Input-output, test time 1 minute, leakage current < 1mA | 1500 | -- | -- | VDC | |
| Insulation Resistance | Input-output, insulation voltage 500VDC | 1000 | -- | -- | MΩ | |
| Isolation Capacitor | Input-output, 100KHz/0.1V | -- | 1000 | -- | pF | |
| Working Temperature | Using the Reference Temperature Derating Curve | -40 | -- | +85 | °C | |
| Storage Temperature | -40 | -- | +125 | °C | ||
| Max Operating Case Temperature | -- | -- | +100 | °C | ||
| Storage Humidity | No condensation | 5 | -- | 95 | %RH | |
| Pin Soldering | Solder joint distance from shell 1.5mm, 10 seconds | -- | -- | +300 | °C | |
| On-off Level | PWM model | -- | 250 | -- | KHz | |
| Vibration | 10-55Hz, 10G, 30 Min. along X, Y and Z | |||||
| Shell Material | Aluminum shell | |||||
| Minimum Time Between Failures | MIL-HDBK-217F@25°C | -- | 2X105 | -- | Hrs | |
2.3. Package Size and Pin Function Diagram

| 1 | 2 | 3 | 4 | 5 | 6 | |
|---|---|---|---|---|---|---|
| Single(S) | +Vin | -Vin | CTRL | Trim | -Vo | +Vo |
| Input+ | Input- | Remote control | Voltage regulator | Output- | Output+ | |
| Dual(D) | +Vin | -Vin | CTRL | -Vo2 | COM | +Vo1 |
| Input- | Input- | Remote control | Output-2 | Common ground | Output+1 |
Note: If the definition of each pin of the power module is inconsistent with the selection manual, the label on the physical label shall prevail.
3. Installation and Setup
3.1. Recommended Test Circuit

To further reduce input and output ripple, external capacitors D1, C2, C3 can be increased, or a capacitor with small series equivalent impedance can be used. Ensure the capacitance value does not exceed the maximum capacitive load of the product.
3.2. EMC Solutions - Recommended Circuits
For general ripple & noise requirements, it is recommended to use only C2 and C5 for the periphery. For strict ripple & noise requirements, the full circuit diagram below is recommended.

Note: C2, C3, C5, C6 should be high-frequency low-resistance electrolytic capacitors. The total capacity must not exceed the maximum capacitive load specified in the manual, otherwise the module may not start normally. When using capacitive load, a minimum load of 3% must be guaranteed to prevent abnormal output.
3.3. Trim and Calculation of Trim Resistance
The Trim function allows for output voltage adjustment. Refer to the pin diagram for the Trim pin location.
Calculation formula of Trim resistance:
- UP: RT = (R*R2) / (R2-R) - R3 (where R = (Vref / (Vo-Vref)) * R1)
- DOWN: RT = (R*R1) / (R1-R) - R3 (where R = (Vo-Vref / Vref) * R2)
RT is the Trim resistance. The 'R' value is a custom parameter without substantive meaning.
Reference values for Vout vs. R1, R2, R3, Vref:
| Vout(V) | R1(KΩ) | R2(KΩ) | R3(KΩ) | Vref(V) |
|---|---|---|---|---|
| 3.3 | 30 | 18.261 | 84.5 | 1.25 |
| 5 | 45.3 | 14.778 | 84.5 | 1.25 |
| 9 | 30 | 11.441 | 84.5 | 2.5 |
| 12 | 56 | 14.571 | 84.5 | 2.5 |
| 15 | 56 | 11.218 | 84.5 | 2.5 |
| 24 | 84.5 | 9.791 | 84.5 | 2.5 |
4. Operating Instructions
4.1. Temperature Derating Curve
The module's output power is affected by the ambient temperature. Refer to the temperature derating curve to ensure operation within safe limits.

4.2. Ripple & Noise Test Method
To accurately measure ripple and noise, use the following method:
- Connect the ripple noise by a 12# twisted pair cable.
- Set the oscilloscope bandwidth to 20MHz and the probe bandwidth to 100M.
- Connect a 0.1uF polypropylene capacitor and a 47uF high-frequency low-resistance electrolytic capacitor in parallel on the probe end.
- Use the Sample sampling mode on the oscilloscope.
Schematic diagram of output ripple noise test:
Connect the power input terminal to the input power supply. The power output is connected to the electronic load through the fixture board. Use a 30cm ± 2cm sampling line to directly sample from the power output port. Select the power line with the insulation sheath of the corresponding wire diameter according to the magnitude of the output current.

5. Maintenance
The Hi-Link 30W DC-DC power modules are designed for high reliability and long life, requiring minimal maintenance under normal operating conditions. Ensure the module operates within the specified temperature range and input/output parameters to maximize its lifespan.
Regularly inspect connections for secure fit and check for any signs of physical damage or overheating. Keep the module free from dust and moisture to maintain optimal performance.
6. Troubleshooting
- Module not starting normally: Ensure the maximum capacitive load connected to +Vo or -Vo does not exceed the specified limit. Exceeding this value will prevent the product from starting.
- Abnormal output when capacitive load is used: A minimum load of 3% must be guaranteed when using capacitive loads. Failure to do so may result in abnormal module output.
- Permanent damage to the product: Input voltage exceeding the maximum specified value may cause irreversible damage. Always verify input voltage before connecting.
- Incorrect Output Voltage: If the output voltage is significantly different from the expected value (e.g., 29.5V or 21V instead of 14V), verify the specific model number and its corresponding output voltage in the 'Product Mode List' table. Ensure the correct module is being used for the desired output.
7. User Tips
- Verify Model Output: Always double-check the specific model number (e.g., URB2412LD-30WR3) against the 'Product Mode List' to confirm the expected output voltage and current. This helps prevent issues like receiving an unexpected voltage.
- Proper Load Management: When using capacitive loads, ensure a minimum 3% load is present to avoid unstable output.
- Consult PDF Manual: For detailed technical diagrams and comprehensive instructions, refer to the official user manual PDF.
8. Warranty and Support
For any technical support, warranty claims, or further inquiries, please contact Shenzhen Hi-Link Electronic Co., Ltd using the information below:
- Company: Shenzhen Hi-Link Electronic Co., Ltd
- Address: Room 301, Building 1, 1970 Science & Technology Park, Minzhi Community, Minzhi Street, Longhua District, Shenzhen
- Website: www.hlktech.com
- Email: sales@hlktech.com
- Tel: 0755-23152658
A comprehensive user manual in PDF format is also available for download. You can access it via this link: Hi-Link 30W DC-DC Power Module User Manual (PDF).