Hi-Link URB____LD-30WR3

Contents

Hi-Link 30W DC-DC Switching Step-Down Power Supply Module User Manual

Models: URB2403LD-30WR3, URB2405LD-30WR3, URB2412LD-30WR3, URB2415LD-30WR3, URB2424LD-30WR3, URB4803LD-30WR3, URB4805LD-30WR3, URB4812LD-30WR3, URB4815LD-30WR3, URB4824LD-30WR3, URB1D03LD-30WR3, URB1D05LD-30WR3, URB1D12LD-30WR3, URB1D15LD-30WR3, URB1D24LD-30WR3, URA2405LD-30WR3, URA2412LD-30WR3, URA2415LD-30WR3, URA2424LD-30WR3, URA4805LD-30WR3, URA4812LD-30WR3, URA4815LD-30WR3, URA4824LD-30WR3, URA1D05LD-30WR3, URA1D12LD-30WR3, URA1D15LD-30WR3, URA1D24LD-30WR3

1. Product Overview

The Hi-Link 30W DC-DC power module series offers compact, high-efficiency (up to 91%) converters with a 4:1 wide voltage input range. These modules feature 1500VDC conventional isolation voltage and are designed for robust performance across various applications.

Key features include:

  • Ultra-wide input voltage range (4:1)
  • Output power: 30W
  • High conversion efficiency: 91% (Typical)
  • Isolation voltage: 1500VDC
  • Ultra-low standby power consumption: 0.036W (Typical)
  • Fast startup: 1mS (Typical)
  • Wide operating temperature range: -40°C to +85°C
  • Comprehensive output protection: short circuit, over-current, and over-voltage protection
  • Metal case for low output ripple
  • International standard pins, suitable for PCB board in-line installation
  • Sealed with high-quality environmental protection waterproof and thermal conductive glue, providing moisture-proof and vibration-proof properties, meeting IP65 requirements.
  • High reliability and long continuous working time.
Hi-Link 30W DC-DC Converter Series
Figure 1: Overview of Hi-Link 30W DC-DC Converter Series, showing various models with different input/output specifications.
Video 1: A promotional video showcasing various Hi-Link AC/DC and DC/DC power modules, highlighting their professional manufacturing and certifications.

2. Specifications

2.1. Product Mode List

Product ModeInput Voltage Range (Vdc)Output Voltage (Vdc)Output Current (mA)(Max.)Ripple and Noise (mVp-p) (Typ./Max.)Maximum Capacitive Load (μF Max.)Efficiency %(Min./Typ.)
URB2403LD-30WR324 (9~36)3.37000/030/501000086/88
URB2405LD-30WR356000/030/501000088/90
URB2412LD-30WR3122500/050/80160088/90
URB2415LD-30WR3152000/050/80100089/91
URB2424LD-30WR3241250/050/8050089/91
URA2405LD-30WR324 (9~36)±5±3000/030/50200085/87
URA2412LD-30WR3±12±1250/050/8080088/90
URA2415LD-30WR3±15±1000/050/8060088/90
URA2424LD-30WR3±24±625/050/8030087/89
URB4803LD-30WR348 (18~75)3.37000/030/50250080/82
URB4805LD-30WR356000/030/50220088/90
URB4812LD-30WR3122500/050/8068087/89
URB4815LD-30WR3152000/050/8047088/90
URB4824LD-30WR3241250/050/8047088/90
URA4805LD-30WR348 (18~75)±5±3000/030/50200084/86
URA4812LD-30WR3±12±1250/050/8080088/90
URA4815LD-30WR3±15±1000/050/8047088/90
URA4824LD-30WR3±24±625/050/8030087/89
URB1D03LD-30WR3110 (40~160)3.37000/030/501000085/87
URB1D05LD-30WR356000/030/501000086/88
URB1D12LD-30WR3122500/050/80220088/90
URB1D15LD-30WR3152000/050/80100089/91
URB1D24LD-30WR3241250/050/8047089/91
URA1D05LD-30WR3110 (40~160)±5±3000/030/50400084/86
URA1D12LD-30WR3±12±1250/050/80100088/90
URA1D15LD-30WR3±15±1000/050/8047089/91
URA1D24LD-30WR3±24±625/050/8022089/91

Note: Due to limited space, this list is typical. For other products, please contact the sales department. The maximum capacitive load must not be exceeded, or the product may not start normally. Input voltage exceeding the maximum value may cause permanent damage.

2.2. General Characteristics

ItemWorking ConditionsMin.Typ.Max.Units
Insulation VoltageInput-output, test time 1 minute, leakage current < 1mA1500----VDC
Insulation ResistanceInput-output, insulation voltage 500VDC1000----MΩ
Isolation CapacitorInput-output, 100KHz/0.1V--1000--pF
Working TemperatureUsing the Reference Temperature Derating Curve-40--+85°C
Storage Temperature-40--+125°C
Max Operating Case Temperature----+100°C
Storage HumidityNo condensation5--95%RH
Pin SolderingSolder joint distance from shell 1.5mm, 10 seconds----+300°C
On-off LevelPWM model--250--KHz
Vibration10-55Hz, 10G, 30 Min. along X, Y and Z
Shell MaterialAluminum shell
Minimum Time Between FailuresMIL-HDBK-217F@25°C--2X105--Hrs

2.3. Package Size and Pin Function Diagram

Package Size and Pin Function Diagram
Figure 2: Detailed dimensions (in mm and inches) and pin layout for the DC-DC converter module. Includes top, bottom, and lateral views, along with a grid for pin spacing.
123456
Single(S)+Vin-VinCTRLTrim-Vo+Vo
Input+Input-Remote controlVoltage regulatorOutput-Output+
Dual(D)+Vin-VinCTRL-Vo2COM+Vo1
Input-Input-Remote controlOutput-2Common groundOutput+1

Note: If the definition of each pin of the power module is inconsistent with the selection manual, the label on the physical label shall prevail.

3. Installation and Setup

Recommended Test Circuit Diagram
Figure 3: Recommended test circuit for DC/DC converters. D1: 47-100 μF; C2, C3: 10-22μF. All units are tested with this circuit before leaving the factory.

To further reduce input and output ripple, external capacitors D1, C2, C3 can be increased, or a capacitor with small series equivalent impedance can be used. Ensure the capacitance value does not exceed the maximum capacitive load of the product.

For general ripple & noise requirements, it is recommended to use only C2 and C5 for the periphery. For strict ripple & noise requirements, the full circuit diagram below is recommended.

EMC Solution Circuit Diagram
Figure 4: Recommended circuit for EMC solutions, including FUSE, MOV Varistor, LDM1, E1, C0, C1, LDM2, and CY1 components.

Note: C2, C3, C5, C6 should be high-frequency low-resistance electrolytic capacitors. The total capacity must not exceed the maximum capacitive load specified in the manual, otherwise the module may not start normally. When using capacitive load, a minimum load of 3% must be guaranteed to prevent abnormal output.

3.3. Trim and Calculation of Trim Resistance

The Trim function allows for output voltage adjustment. Refer to the pin diagram for the Trim pin location.

Calculation formula of Trim resistance:

  • UP: RT = (R*R2) / (R2-R) - R3 (where R = (Vref / (Vo-Vref)) * R1)
  • DOWN: RT = (R*R1) / (R1-R) - R3 (where R = (Vo-Vref / Vref) * R2)

RT is the Trim resistance. The 'R' value is a custom parameter without substantive meaning.

Reference values for Vout vs. R1, R2, R3, Vref:

Vout(V)R1(KΩ)R2(KΩ)R3(KΩ)Vref(V)
3.33018.26184.51.25
545.314.77884.51.25
93011.44184.52.5
125614.57184.52.5
155611.21884.52.5
2484.59.79184.52.5

4. Operating Instructions

4.1. Temperature Derating Curve

The module's output power is affected by the ambient temperature. Refer to the temperature derating curve to ensure operation within safe limits.

Temperature Derating Curve
Figure 5: Temperature Derating Curve showing the relationship between output power percentage and environment temperature. Full power is maintained up to 55°C, with derating occurring above this temperature.

4.2. Ripple & Noise Test Method

To accurately measure ripple and noise, use the following method:

  1. Connect the ripple noise by a 12# twisted pair cable.
  2. Set the oscilloscope bandwidth to 20MHz and the probe bandwidth to 100M.
  3. Connect a 0.1uF polypropylene capacitor and a 47uF high-frequency low-resistance electrolytic capacitor in parallel on the probe end.
  4. Use the Sample sampling mode on the oscilloscope.

Schematic diagram of output ripple noise test:

Connect the power input terminal to the input power supply. The power output is connected to the electronic load through the fixture board. Use a 30cm ± 2cm sampling line to directly sample from the power output port. Select the power line with the insulation sheath of the corresponding wire diameter according to the magnitude of the output current.

Output Ripple Noise Test Setup
Figure 6: Diagram illustrating the setup for measuring output ripple and noise, including the fixture board, power module, load, and DPO probe connection.

5. Maintenance

The Hi-Link 30W DC-DC power modules are designed for high reliability and long life, requiring minimal maintenance under normal operating conditions. Ensure the module operates within the specified temperature range and input/output parameters to maximize its lifespan.

Regularly inspect connections for secure fit and check for any signs of physical damage or overheating. Keep the module free from dust and moisture to maintain optimal performance.

6. Troubleshooting

  • Module not starting normally: Ensure the maximum capacitive load connected to +Vo or -Vo does not exceed the specified limit. Exceeding this value will prevent the product from starting.
  • Abnormal output when capacitive load is used: A minimum load of 3% must be guaranteed when using capacitive loads. Failure to do so may result in abnormal module output.
  • Permanent damage to the product: Input voltage exceeding the maximum specified value may cause irreversible damage. Always verify input voltage before connecting.
  • Incorrect Output Voltage: If the output voltage is significantly different from the expected value (e.g., 29.5V or 21V instead of 14V), verify the specific model number and its corresponding output voltage in the 'Product Mode List' table. Ensure the correct module is being used for the desired output.

7. User Tips

  • Verify Model Output: Always double-check the specific model number (e.g., URB2412LD-30WR3) against the 'Product Mode List' to confirm the expected output voltage and current. This helps prevent issues like receiving an unexpected voltage.
  • Proper Load Management: When using capacitive loads, ensure a minimum 3% load is present to avoid unstable output.
  • Consult PDF Manual: For detailed technical diagrams and comprehensive instructions, refer to the official user manual PDF.

8. Warranty and Support

For any technical support, warranty claims, or further inquiries, please contact Shenzhen Hi-Link Electronic Co., Ltd using the information below:

  • Company: Shenzhen Hi-Link Electronic Co., Ltd
  • Address: Room 301, Building 1, 1970 Science & Technology Park, Minzhi Community, Minzhi Street, Longhua District, Shenzhen
  • Website: www.hlktech.com
  • Email: sales@hlktech.com
  • Tel: 0755-23152658

A comprehensive user manual in PDF format is also available for download. You can access it via this link: Hi-Link 30W DC-DC Power Module User Manual (PDF).

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.