1. Overview
This series of instruments is a highly reliable digital clamp meter with stable performance and lithium battery drive. It features a full symbol, 17mm word height LCD display for clear reading. The adjustable screen brightness adapts to various environments, protects the eyes, and allows for screen rotation for easy reading. Additionally, it includes full-function overload protection.
This instrument can measure the true effective value of DC voltage and AC voltage, DC current and AC current (clamp type), resistance, capacitance, frequency, Celsius, Fahrenheit, diode, on/off, and is capable of leakage detection in various scenarios. The core of the machine is a dual integral A/D conversion, making it a cost-effective tool with superior performance. It is an ideal tool for laboratories, factories, radio enthusiasts, and families.
2. Safety Precautions
The design of this series of instruments complies with IEC1010 safety standards. Please read the following safety precautions before use:
- Always use the clamp meter according to the instructions. Failure to do so may compromise the safety function of the device.
- Comply with national safety regulations. When working in environments with high voltage and exposed wires, use personal protective equipment to prevent injuries from electric shock or arc discharge.
- Do not hold the current clamp meter in any position other than the protective shield.
- Before each use, inspect the outer shell of the clamp for cracks or defects, and pay special attention to the insulation around the clamp mouth.
- When replacing the battery, ensure the clamp is removed from all live circuits and leads are disconnected.
- When changing the function or range, ensure the probe leaves the test point first.
- Voltage below 36V is considered safe. When measuring voltage above 36V DC or 25V AC, ensure reliable probe contact, correct connection, and good insulation to prevent electric shock.
- Do not input voltage exceeding the effective value of DC 1000V or AC 750V to prevent damage to the instrument circuit.
3. Common Symbols
Familiarize yourself with the symbols displayed on the meter:
| Symbol | Description |
|---|---|
| ▲ | Warning prompt |
| ⚡ | High voltage hazard |
| ☐ | Double insulation |
| ⏚ | Grounding |
![]() | Low battery level |
| ▶| | Diode |
| 🔊 | Buzzer |
| ZERO | Zero clearing |
| ~ | AC |
| --- | DC |
| VFC | Variable frequency conversion |
| EF | Electric field measurement |
| LIVE | Fire line measurement |
| NCV | Non-contact measurement |
| HOLD | Data hold |
4. Product Features and Characteristics
The WINAPEX 268B Digital Clamp Meter offers a wide range of functions and user-friendly features:

4.1. General Characteristics
- Display Method: LCD display
- Maximum Display: 5999 (3 5/6), with automatic polarity display
- Measurement Method: Double integral A/D conversion
- Updates per Second: 2-3 times
- Over Range Display: "OL" appears at the highest position
- Low Voltage Display: Battery symbol appears
- Working Environment: 0-40°C, relative humidity <80%
- Power Supply: 3.7V lithium battery
- Dimensions (L x W x T): 165 x 68 x 26mm
- Weight: Approximately 280g (including battery)
4.2. Technical Characteristics (Model 268B)
The following table details the technical specifications for the 268B model. Note: "▲" indicates the function is available, "*" indicates the range is not available for this model.
| Function | 268B |
|---|---|
| ACV/DCV | ▲ |
| ACA | ▲ |
| DCA | ▲ |
| Resistance Ω | ▲ |
| Capacitance C | ▲ |
| Frequency F | ▲ |
| Degrees Celsius/Fahrenheit | ▲ |
| Diode/on/off detection | ▲ |
| Zero capacitance ZERO | ▲ |
| NCV | ▲ |
| LIVE | ▲ |
| Leakage detection | ▲ |
| Voice reporting | None |
| Screen Rotation | ▲ |
| Screen brightness adjustable | ▲ |
| Charging USB | ▲ |
| Flashlight | ▲ |
| Automatic shutdown | ▲ |
5. Setup
5.1. Package Contents
Before using your WINAPEX 268B Digital Clamp Meter, please verify that all items are present in the package:
- 1x WINAPEX 268B Digital Clamp Meter
- 1x User Manual (this document)
- 1x Certificate of Conformity
- 1x Warranty Card
- 1x Color Box
- 1x Test Lead set
- 1x TP01 Thermocouple
- 1x Lithium Battery (pre-installed in the body)
- 1x Cloth Bag / Carrying Case
- 1x USB Charging Cable


5.2. Battery Installation and Charging
The WINAPEX 268B comes with a pre-installed 3.7V lithium battery. If the low battery symbol appears on the display, recharge the device using the provided USB Type-C cable.

5.3. Brightness Adjustment
The screen brightness can be adjusted to suit different environments. To adjust:
- Press and hold the "Brightness" button (often indicated by a sun icon) for more than 2 seconds until a short beep sounds. Release the button to enter brightness adjustment mode.
- Press and hold the "Brightness" button again to cycle through the five brightness levels.
- Once the desired brightness is set, press and hold the button again until a short beep sounds, then release to exit brightness adjustment mode.
6. Description of Operation Panel
The WINAPEX 268B Digital Clamp Meter features an intuitive operation panel. Refer to the diagram below for component identification:

- Clamp Head Clamp: Used to clamp around a single conductor for current measurement.
- Model Sticker: Displays the model number (e.g., WINAPEX 268B).
- LCD Display Screen: Shows measurement readings, function indicators, and other information.
- Rotating Screen Button: Long press to rotate the display screen for better viewing angles.
- USB Charge Port: Type-C port for charging the internal lithium battery.
- Silicone Button Group: Contains various function buttons (e.g., SELECT, HOLD, EF/LIVE, ZERO).
- Indicator Light: Provides visual feedback (beeping, EF/LIVE mode, or flashing red when active).
- Test Positive End: Red input terminal for connecting the red test probe.
- Test Negative Terminal: Black input terminal for connecting the black test probe (COM).
- Pliers Trigger: Squeeze to open the clamp head.
7. Operating Instructions
7.1. DC Voltage Measurement (DCV)
Input impedance: All ranges are 10MΩ. Overload protection: DC1000V or 750V AC peak.
- Insert the black test lead into the "COM" socket and the red test lead into the "V Ω" socket.
- When the probe reliably contacts the test point, the screen will display the measured voltage value. The displayed value indicates the voltage and polarity of the point connected to the red probe.
- When measuring high voltage, exercise caution and avoid touching the high voltage circuit.
- Do not exceed the input voltage of DC1000V or AC750V to prevent damage to the instrument circuit.
7.2. AC Voltage Measurement (ACV) RMS
Input impedance: All ranges are 10MΩ. Overload protection: 1000V DC or AC peak. Frequency response: True RMS measurable: Sine wave, triangular wave: (40-1000) Hz, other waveforms: (40-200) Hz.
- Insert the black test lead into the "COM" socket and the red test lead into the "V Ω" socket.
- When the test probe reliably contacts the test point, the screen will display the measured voltage value.
- The measured voltage should not exceed AC750V. Ensure the probe leaves the test point before turning off or changing the functional gear.
- When measuring high voltage, exercise caution and avoid touching the high voltage circuit.
7.3. DC Current Measurement (DCA) - Clamp Type
Minimum measurement current: 5mA. Maximum measurement current: 60A. Over range display: "OL". Overload protection: 60A.
- Before testing, close the clamp head and press the "ZERO" key to reset it. If it is not zero, press it multiple times to zero the reading.
- Record the reading after the test, and repeat the reset step for each measurement.
- Be careful when measuring high voltage electricity to avoid electric shock.

7.4. AC Current Measurement (ACA) - Clamp Type
All currents are automatic ranges. When measuring large currents, the range is identified from small to large. The larger the fixed current value, the longer the measurement time will be. When the displayed value shows "OL", it indicates that the measured value has exceeded the maximum current measurement value of the clamp meter.
Maximum measured current: 60A for 268B. Testing frequency: 30Hz to 1kHz for 268B. Minimum measurement current: AC2mA for 268B.
- When measuring AC current, only one live wire (phase wire) can be clamped.
- Keep the wire in the center position of the clamp, and then read the data from the screen.
- When measuring current, the two clamps should be tightly connected without gaps. Otherwise, the measurement error will be too large.

7.5. Resistance Measurement (Ω)
Input impedance: 10MΩ. Maximum test voltage: 3V. Overload protection: 250V DC or AC peak.
Warning: Input voltage prohibited in this range. May damage the instrument panel.
- Insert the black test lead into the "COM" socket and the red test lead into the "V Ω" socket.
- Press the "SELECT" button to automatically or manually select the functional gear on the resistance page.
- Connect the two probes across the measured resistance.
- When using a 600 Ω range, short-circuit the probe first to measure the lead resistance, then subtract it from the actual measurement.
- When measuring above 1MΩ, the reading may react slowly. Wait for the displayed value to stabilize.
- If the resistance value exceeds 60MΩ, "OL" will be displayed.
- When measuring online resistance, ensure the power supply of the tested circuit is off and all capacitors are fully discharged.
- When the measured resistance value exceeds 1MΩ, it may take several seconds for the reading to stabilize. This is normal.
7.6. Diode and On/Off Test
Overload protection: 250V DC or AC peak.
Warning: Input voltage prohibited in this range.
- Insert the black test lead into the "COM" socket and the red test lead into the "V Ω" socket (red lead is "+").
- Press the "SELECT" key to switch to the diode/on/off test position.
- Connect the red probe to the positive pole of the diode and the black probe to the negative pole. The reading will show the positive voltage drop value of the diode in "V".
- To test continuity, connect the probe to two points of the circuit. If the built-in buzzer sounds, the resistance value between the two points is less than approximately 50 ± 20 Ω.
7.7. Capacitance Measurement (C)
Overload protection: 250V DC or AC peak.
Warning: Input voltage prohibited in this range.
- Insert the black test lead into the "COM" socket and the red test lead into the "V Ω" socket.
- Press the "SELECT" key to switch to the capacitance page.
- Connect the two probes across the measured capacitance.
- If the measured capacitance exceeds the maximum value of the range, "OL" will be displayed.
- If there is severe leakage or breakdown short circuit of the capacitor, a numerical value will be displayed and may be unstable.
- Before testing, the capacitor should be fully discharged to prevent damage to the instrument.
- When capacitance is not measured, a certain base number may be present. Before measuring, press the "ZERO" button to reset it to zero.
7.8. Frequency Measurement (Hz) - 268B Only
Input sensitivity: 1.5V effective value. Overload protection: 250V DC or AC peak (not exceeding 10 seconds).
- Insert the probe or shielded cable into the "COM" and "V Ω" sockets.
- Press the "SELECT" key to switch to the frequency page.
- Connect the probe or cable to the signal source or tested load.
- If the input exceeds 10Vrms, it can be read, but it may exceed the tolerance.
- In noisy environments, it is best to use shielded cables when measuring small signals.
- When measuring high voltage circuits, special attention should be paid to avoiding electric shock.
- It is prohibited to input voltage values exceeding 250V DC or AC peak to avoid damaging the instrument.
7.9. Temperature Measurement (°C/°F)
Overload protection: 250V DC or AC peak. Temperature measuring probe: K-type TP01 thermocouple (banana plug).
- Press the "SELECT" key to switch to the temperature page.
- Insert the negative end of the temperature measurement probe into the "COM" input port and the positive end into the "V Ω" hole.
- The temperature measurement range is -20 to 1000 °C. If it is too large, "OL" will be displayed.
- When the input terminal is open, the ambient temperature is displayed (for reference only, if operating environment is 18-28°C).
- Do not replace the temperature sensor arbitrarily, as measurement accuracy cannot be guaranteed.
- It is strictly prohibited to input voltage in the temperature range.
7.10. Non-Contact Voltage (NCV) Measurement / Live Wire Measurement (LIVE)
- Press the "EF/LIVE" key. The screen displays "EF" and enters non-contact electric field measurement mode.
- Place the front end of the instrument near the AC voltage. Depending on the signal strength, the buzzer will emit sounds at different intervals, and the LCD will display different segments.
- Press the "EF/LIVE" key again in NCV mode. The screen displays "LIVE" to enter live line measurement mode.
- Insert the red probe into the "V Ω" socket (single probe operation is sufficient). If the buzzer emits a continuous sound, it indicates a live wire. "OL" will simultaneously display on the screen.
- This function is applicable to frequency signals ranging from 50Hz to 1kHz.
7.11. Leakage Current Detection
The WINAPEX 268B model supports leakage current detection.
- Detecting leakage current on the grounding wire: Open the trigger and clamp the pliers around the ground wire. Check the reading displayed on the LCD for the leakage current value.
- Single-phase AC leakage current detection: Open the trigger and clamp the power supply (neutral and live wires) together with the clamp head. The reading displayed on the instrument is the leakage current value.
- Three-phase three-wire leakage current detection: Open the trigger and clamp three live wires. The reading displayed by the instrument on the live line is the leakage current value.
- Three-phase four-wire leakage current detection: Open the trigger and clamp the three live wires with the clamp head. Do not clamp the ground wire. The instrument display reading is the leakage current value.
7.12. Data Hold
Short press the "HOLD" button to hold the displayed data. Short press "HOLD" again to unlock the data.
7.13. Flashlight Function
To use the flashlight:
- Press and hold the "Flashlight" button (often indicated by a lightbulb icon) until the flashlight turns on.
- Press and hold the "Flashlight" button again to turn off the flashlight.
7.14. Automatic Shutdown
When the instrument is turned on for 15 minutes, it will automatically power off and enter a sleep state. Before turning off, a five-tone prompt will sound. To restart the power supply, press and hold the power button for more than 2 seconds.
8. Maintenance
8.1. Battery Charging
The WINAPEX 268B uses a built-in 3.7V lithium battery. If the low battery symbol appears on the display, recharge the device using the provided Type-C USB cable.

8.2. Cleaning and Storage
- Clean the instrument with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Store the clamp meter in its cloth bag/carrying case in a cool, dry place away from direct sunlight and extreme temperatures.
- Ensure the device is fully charged before long-term storage to maintain battery health.
9. Troubleshooting
If your instrument cannot function properly, the following methods can help you quickly solve general problems. If the fault persists, please contact the repair center or dealer.
| Fault Phenomenon | Inspection Location and Method |
|---|---|
| No display | Power not connected / Battery needs charging or replacement |
| Large resistance display error | The test lead is not in good contact |
| "OL" displayed during measurement | Measured value exceeds the maximum range for the selected function. |
| Slow reading for high resistance | Normal behavior for resistance measurements above 1MΩ. Wait for stabilization. |
| Unstable capacitance reading | Indicates severe leakage or breakdown short circuit of the capacitor. |
| Buzzer sounds continuously during live wire test but no "OL" | Ensure the red probe is correctly inserted into the V Ω socket and making good contact. |
10. Specifications
10.1. DC Voltage (DCV)
| Range | Accuracy (268B) | Resolution |
|---|---|---|
| 6V | ±(0.5%+3) | 1mV |
| 60V | ±(0.5%+3) | 10mV |
| 600V | ±(0.5%+3) | 100mV |
| 1000V | ±(0.8%+10) | 1V |
10.2. AC Voltage (ACV) RMS
| Range | Accuracy (268B) | Resolution |
|---|---|---|
| 6V | ±(0.8%+3) | 1mV |
| 60V | ±(0.8%+3) | 10mV |
| 200V | * | 100mV |
| 600V | ±(0.8%+3) | 100mV |
| 750V | ±(1.2%+10) | 1V |
10.3. DC Current (DCA) - Clamp Type
| Range | Accuracy (268B) | Resolution |
|---|---|---|
| 6A | ±(2.0%+5) | 1mA |
| 60A | ±(2.0%+3) | 10mA |
10.4. AC Current (ACA) - Clamp Type
| Range | Accuracy (268B) | Resolution |
|---|---|---|
| 60mA | * | 0.01mA |
| 600mA | ±(1.5%+10) | 0.1mA |
| 6A | ±(2.5%+5) | 1mA |
| 60A | ±(2.0%+5) | 10mA |
| 100A | * | 100mA |
| 500A | * | 1A |
10.5. Resistance (Ω)
| Range | Accuracy (268B) | Resolution |
|---|---|---|
| 600Ω | ±(0.8%+5) | 0.1Ω |
| 6kΩ | ±(0.8%+3) | 1Ω |
| 60kΩ | ±(0.8%+3) | 10Ω |
| 600kΩ | ±(0.8%+3) | 100Ω |
| 6MΩ | ±(0.8%+3) | 1kΩ |
| 60MΩ | ±(2.5%+15) | 10kΩ |
10.6. Capacitance (C)
| Range | Accuracy (268B) | Resolution |
|---|---|---|
| 6nF | ±(3.5%+20) | 1pF |
| 60nF | ±(3.5%+20) | 10pF |
| 600nF | ±(3.5%+20) | 100pF |
| 6uF | ±(3.5%+20) | 1nF |
| 60uF | ±(3.5%+20) | 10nF |
| 600uF | ±(3.5%+20) | 100nF |
| 6mF | ±(3.5%+20) | 1uF |
| 60mF | ±(5.0%+20) | 10uF |
10.7. Frequency (Hz) - 268B Only
| Range | Accuracy (268B) | Resolution |
|---|---|---|
| 6Hz | ±(0.5%+5) | 0.001Hz |
| 60Hz | ±(0.5%+5) | 0.01Hz |
| 600Hz | ±(0.5%+5) | 0.1Hz |
| 6kHz | ±(0.5%+5) | 1Hz |
| 60kHz | ±(0.5%+5) | 10Hz |
| 600kHz | ±(0.5%+5) | 100Hz |
| 6MHz | ±(0.5%+5) | 1kHz |
| 10MHz | ±(0.5%+5) | 10kHz |
10.8. Temperature Measurement (°C/°F)
| Range | Accuracy (268B) | Resolution |
|---|---|---|
| (-20-1000)°C | ±(1.5%+15) ≥400°C | 1°C |
| (0-1832)°F | ±(1.5%+15) ≥750°F | 1°F |
11. User Tips
- The compact size and comfortable grip make this clamp meter easy to handle for various tasks.
- The separate button to operate the clamp is a convenient feature for quick and efficient measurements.
- The device is noted for its completeness and functionality, making it a versatile tool for electrical work.
12. Warranty and Support
This product includes a Certificate of Conformity and a Warranty Card. Please refer to these documents for specific warranty terms and conditions.
For any issues not covered in this manual or for repair services, please contact your dealer or the manufacturer's customer support.
The content of this manual is subject to change without notice. Our company shall not be responsible for accidents and hazards caused by user error operations. The functions described in this manual are not intended as a reason for using the product for special purposes.
A PDF version of the user manual is available for download: WINAPEX 268 Series User Manual (PDF)