WinAPEX 268B

Contents

WinAPEX 268B AC/DC Clamp Meter User Manual

Model: 268B | Brand: WinAPEX

1. Overview

The WinAPEX 268B is a highly reliable digital clamp meter designed for stable performance and powered by a lithium battery. It features a full-symbol, 17mm high LCD display for clear readings, with adjustable screen brightness and screen rotation for optimal viewing in various environments. This instrument offers comprehensive overload protection and can measure true effective values for DC and AC voltage, DC and AC current (clamp type), resistance, capacitance, frequency, temperature (Celsius/Fahrenheit), diode, and continuity. It also includes advanced leakage detection capabilities for diverse applications, making it an ideal tool for professionals and enthusiasts alike.

WinAPEX 268B Clamp Meter with accessories

Figure 1: WinAPEX 268B Clamp Meter and included accessories.

2. Safety Precautions

To ensure safe operation and prevent damage to the instrument or injury, please read and follow these safety precautions carefully:

  • Always use the clamp meter according to the instructions provided in this manual. Failure to do so may compromise the built-in safety features.
  • Comply with all national safety regulations. When working in environments with high voltage or exposed wires, always use appropriate personal protective equipment to prevent electric shock or arc flash injuries.
  • Do not hold the clamp meter by any part other than the protective shield.
  • Before each use, inspect the outer casing of the clamp for any cracks or defects, paying close attention to the insulation around the clamp jaws.
  • When replacing the battery, ensure the clamp meter is disconnected from all live circuits and test leads are removed.
  • Always remove the probe from the test point before changing functions or ranges.
  • Voltages below 36V DC or 25V AC are generally considered safe. When measuring voltages above these levels, ensure test lead contacts are reliable, correctly connected, and properly insulated to prevent electric shock.
  • Do not input voltages exceeding the effective value of 1000V DC or 750V AC to avoid damaging the instrument.

3. Package Contents

Please check the package for the following items:

  • 1 x WinAPEX 268B Digital Clamp Meter
  • 1 x User Manual
  • 1 x Certificate of Conformity
  • 1 x Warranty Card
  • 1 x Color Box
  • 1 x Test Lead Set (Red and Black)
  • 1 x TP01 Thermocouple
  • 1 x Lithium Battery (pre-installed in the device)
  • 1 x Cloth Carrying Bag
  • 1 x USB Type-C Charging Cable
Package contents of WinAPEX 268B

Figure 2: Contents included in the WinAPEX 268B package.

4. Device Layout and Controls

Familiarize yourself with the components and controls of your WinAPEX 268B Clamp Meter:

Diagram of the WinAPEX 268B Clamp Meter with numbered parts

Figure 3: WinAPEX 268B Clamp Meter with labeled parts.

  1. Clamp Head
  2. Model Sticker
  3. LCD Display Screen
  4. Rotating Screen Button (long press to activate)
  5. USB Type-C Charge Port
  6. Silicone Button Group (Power, Select, Hold, EF/Live, Zero)
  7. Indicator Light (for beeping, EF, LIVE, and active flashing red)
  8. Test Positive End (for red probe)
  9. Test Negative Terminal (for black probe)
  10. Pliers Trigger (to open clamp head)

5. Initial Setup

5.1. Charging the Battery

The WinAPEX 268B is equipped with a built-in 3.7V, 750mAh lithium battery, providing approximately 20 hours of continuous operation on a full charge. To charge the device:

  • Connect the supplied USB Type-C charging cable to the USB charge port (5) on the side of the clamp meter.
  • Connect the other end of the USB cable to a standard USB power adapter (not included) or a computer USB port.
  • The display will indicate charging status. Ensure the device is fully charged before first use for optimal battery life.
WinAPEX 268B Clamp Meter being charged via Type-C USB

Figure 4: Charging the WinAPEX 268B via its Type-C USB port.

6. Operating Instructions

The WinAPEX 268B offers a wide range of measurement functions. Use the 'SELECT' button to cycle through different modes. The functional display icons are shown below:

Functional display icons for various measurement modes

Figure 5: Functional display icons for various measurement modes.

6.1. DC Voltage (DCV) Measurement

  • Insert the black test lead into the 'COM' socket and the red test lead into the 'V Ω' socket.
  • Select the DCV mode using the 'SELECT' button.
  • Connect the probes to the circuit points to be measured. The display will show the voltage value and polarity.
  • Precaution: Do not exceed 1000V DC input.

6.2. AC Voltage (ACV) RMS Measurement

  • Insert the black test lead into the 'COM' socket and the red test lead into the 'V Ω' socket.
  • Select the ACV mode using the 'SELECT' button.
  • Connect the probes to the circuit points to be measured. The display will show the RMS voltage value.
  • Precaution: Do not exceed 750V AC input.

6.3. DC Current (DCA) Clamp Measurement

  • Before testing, close the clamp head and press the 'ZERO' button to reset the reading to zero. Repeat if necessary.
  • Select the DCA mode using the 'SELECT' button.
  • Open the clamp jaws using the trigger and enclose only one conductor (not a cable with multiple conductors).
  • Read the DC current value on the display.
  • Precaution: Minimum measurable current is 5mA, maximum is 60A. Overload protection at 60A.

6.4. AC Current (ACA) Clamp Measurement

  • Select the ACA mode using the 'SELECT' button.
  • Open the clamp jaws and enclose only one live wire (phase wire). Ensure the wire is positioned in the center of the clamp for accuracy.
  • Read the AC current value on the display.
  • Precaution: All AC current ranges are automatic. When measuring current, ensure the clamp jaws are tightly closed without gaps.

6.5. Resistance (Ω) Measurement

  • Insert the black test lead into the 'COM' socket and the red test lead into the 'V Ω' socket.
  • Select the Resistance mode using the 'SELECT' button.
  • Connect the probes across the component to be measured.
  • Precaution: Do not input voltage in resistance mode. For online resistance measurement, ensure the circuit power is off and capacitors are discharged.

6.6. Diode and Continuity Test

  • Insert the black test lead into the 'COM' socket and the red test lead into the 'V Ω' socket (red is positive).
  • Select the Diode/Continuity mode using the 'SELECT' button.
  • For diode test: Connect the red probe to the anode and black probe to the cathode. The display shows the forward voltage drop.
  • For continuity test: Connect probes across the circuit. A long beep indicates continuity (resistance less than approx. 50Ω).
  • Precaution: Do not input voltage in this range.

6.7. Capacitance (C) Measurement

  • Insert the black test lead into the 'COM' socket and the red test lead into the 'V Ω' socket.
  • Select the Capacitance mode using the 'SELECT' button.
  • Connect the probes across the capacitor.
  • Precaution: Before testing, ensure the capacitor is fully discharged to prevent damage. Do not input voltage in this range.

6.8. Frequency (Hz) Measurement

  • Insert the black test lead into the 'COM' socket and the red test lead into the 'V Ω' socket.
  • Select the Frequency mode using the 'SELECT' button.
  • Connect the probes to the signal source or load.
  • Precaution: Input sensitivity is 1.5V RMS. Do not input voltage exceeding 250V DC or AC peak.

6.9. Temperature Measurement (°C/°F)

  • Insert the negative end of the TP01 thermocouple into the 'COM' port and the positive end into the 'V Ω' port.
  • Select the Temperature mode using the 'SELECT' button.
  • Place the thermocouple tip on the object to be measured.
  • Precaution: Do not input voltage in temperature mode. Do not replace the temperature sensor arbitrarily.

6.10. Non-Contact Voltage (NCV) and Live Wire Measurement

  • Press the 'EF/LIVE' button to enter NCV mode. Place the front end of the instrument near an AC voltage source. The buzzer will sound, and the LCD will display segments indicating signal strength.
  • Press 'EF/LIVE' again to enter Live Wire mode. Insert the red probe into the 'V Ω' socket. If the buzzer emits a continuous sound, it indicates a live wire.

6.11. Leakage Current Detection

The WinAPEX 268B is capable of detecting leakage currents in various configurations:

  • Grounding Wire Leakage: Clamp the grounding wire. The display shows the leakage current.
  • Single-Phase AC Leakage: Clamp the power supply wire, live wire, and neutral wire together. The display shows the leakage current.
  • Three-Phase Three-Wire Leakage: Clamp the three live wires. The display shows the leakage current.
  • Three-Phase Four-Wire Leakage: Clamp the three live wires and the neutral wire (do not clamp the ground wire). The display shows the leakage current.

6.12. Special Functions

  • Screen Brightness: Press and hold the brightness button (often integrated with flashlight or select) for 2 seconds to enter adjustment mode. Press again to cycle through 5 brightness levels. Hold again to exit.
  • Data Hold: Short press the 'HOLD' button to freeze the current reading on the display. Press 'HOLD' again to release.
  • Flashlight: Press and hold the flashlight button (often integrated with brightness) to turn on/off the built-in flashlight.
  • Voice Alarm (268A, 268C only): This model can report measurement values verbally. Long press the 'LIVE' button to toggle voice reporting on/off.
  • Automatic Shutdown: The instrument automatically powers off after 15 minutes of inactivity to save battery. Press and hold the power button for more than 2 seconds to restart.
  • Screen Rotation: Long press the screen rotation button to rotate the display for easier viewing. Note that this setting may reset after power cycle.

7. Technical Specifications

7.1. General Characteristics

  • Display: LCD, 5999 counts (3 5/6 digits) with automatic polarity.
  • Measurement Method: Double integral A/D conversion.
  • Update Rate: 2-3 times per second.
  • Over Range Indication: 'OL' displayed.
  • Low Battery Indication: Battery symbol appears.
  • Working Environment: 0-40°C, relative humidity <80%.
  • Power Supply: 3.7V Lithium Battery.
  • Dimensions: 165 x 68 x 26mm (Length x Width x Thickness).
  • Weight: Approximately 280g (including battery).
  • Executive Standards: GB/T13978.

7.2. Measurement Ranges and Accuracy (268B Model)

FunctionRangeAccuracyResolution
DC Voltage (DCV)6V±(0.5%+3)1mV
60V10mV
600V100mV
1000V±(0.8%+10)1V
AC Voltage (ACV) RMS6V±(0.8%+3)1mV
60V10mV
200V±(0.8%+3)100mV
750V±(1.2%+10)1V
DC Current (DCA)6A±(2.0%+5)1mA
60A±(2.0%+3)10mA
AC Current (ACA)60mA±(1.2%+8)0.01mA
600mA±(1.5%+10)0.1mA
6A±(2.5%+5)1mA
60A±(2.0%+5)10mA
Resistance (Ω)600Ω±(0.8%+5)0.1Ω
6kΩ±(0.8%+3)1Ω
60kΩ10Ω
600kΩ100Ω
6MΩ±(2.5%+15)1kΩ
60MΩ10kΩ
Capacitance (C)6nF±(3.5%+20)1pF
60nF10pF
600nF100pF
6uF1nF
60uF10nF
600uF100nF
6mF1uF
60mF±(5.0%+20)10uF
Frequency (Hz)6Hz±(0.5%+5)0.001Hz
60Hz0.01Hz
600Hz0.1Hz
6kHz1Hz
60kHz10Hz
600kHz100Hz
Temperature-20 to 1000°C±(1.0%+5) <400°C; ±(1.5%+15) ≥400°C1°C
0 to 1832°F±(0.75%+5) <750°F; ±(1.5%+15) ≥750°F1°F

8. Maintenance

8.1. Cleaning

Wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Ensure the device is dry before use.

8.2. Battery Care

The device uses a rechargeable lithium battery. For optimal battery life, avoid fully discharging the battery frequently and recharge it when the low battery indicator appears. If storing the device for an extended period, charge it to about 50% every few months.

8.3. Storage

Store the clamp meter in a cool, dry place, away from direct sunlight and extreme temperatures. Use the provided cloth carrying bag to protect it from dust and physical damage.

9. Troubleshooting

If your instrument does not function properly, try the following solutions. If the issue persists, contact your dealer or repair center.

Fault PhenomenonInspection Location and Method
No displayCheck if power is connected (press power button). Recharge battery if low.
Large resistance display errorEnsure test leads are in good contact with the circuit/component.
Inaccurate readingsCheck battery level. Ensure correct function/range is selected. Verify proper probe connection.

10. User Tips

  • DC Current Measurement: For accurate DC current readings, ensure you understand the zeroing procedure before clamping the conductor.
  • Automatic Mode Speed: While convenient, automatic measurement mode can sometimes be slower (2-3 seconds per reading) due to internal relay operations. For faster measurements, consider using manual range selection when appropriate.
  • Screen Rotation Reset: The screen rotation setting may not be saved after the device is powered off and on. You may need to re-adjust it for each use.
  • Included Accessories: The quality of the included test probes, thermocouple, and charging cable may vary. For critical applications, consider using higher-quality accessories.
  • Leakage Detection: The leakage current detection function is reported by users to be very effective and precise, even when compared to laboratory instruments.

11. Warranty and Support

This product comes with a warranty card. Please refer to the warranty card for specific terms and conditions regarding coverage and duration. For technical support, service, or warranty claims, please contact your original point of purchase or the authorized WinAPEX distributor.