SZYTF YF-S201

Rate this product if you’ve used it
Contents

SZYTF YF-S201 Water Flow Sensor User Manual

Model: YF-S201

1. Introduction

The SZYTF YF-S201 water flow sensor is a reliable instrument designed for measuring liquid flow. It is commonly used in applications such as water heaters, cooling systems, and water vending machines. This manual provides essential information for the safe and effective use of your water flow sensor.

2. Safety & Warnings

  • Pressure Limit: Do not exceed the maximum hydrostatic pressure of 2.0 MPa. Excessive pressure may cause the housing to rupture or leak.
  • Temperature Limit: The operating temperature of the liquid should not exceed 80°C to prevent damage to the internal plastic components and sensor.
  • Liquid Compatibility: Avoid using the sensor with corrosive chemicals, flammable liquids, or water containing heavy debris that could clog the impeller.
  • Handling: Handle the device with care. Severe impacts or dropping the sensor may damage the precision Hall element and affect measurement accuracy.
  • Wiring: Ensure external wires are not bent at sharp angles to prevent fatigue and internal connection failure.

3. Product Overview

3.1 Components

The YF-S201 water flow sensor consists of:

  • A plastic valve body
  • A water rotor (impeller)
  • A Hall-effect sensor that outputs a pulse signal corresponding to the flow rate

3.2 Key Features

  • Internal impeller inlaid with stainless steel beads for improved wear resistance and service life.
  • High-quality seal ring and waterproof silicone potting for the Hall element to ensure long-term stability and prevent leakage.
  • All raw materials meet ROHS standards.
Two YF-S201 water flow sensors, one black and one white, showing their threaded connections and wiring.
Figure 1: SZYTF YF-S201 Water Flow Sensors (Black and White variants)

4. Setup & Installation

  1. Identify Flow Direction: Locate the arrow on the sensor body. This arrow indicates the direction of water flow. Ensure the sensor is installed correctly in line with your piping system.
  2. Secure Connections: The sensor features G 1/2" external threads. Wrap the connection threads with Teflon tape or use a rubber gasket to ensure a watertight seal.
  3. Wiring: Connect the sensor to your microcontroller or power source as follows:
    • Red Wire: Connect to DC 5V-18V power supply.
    • Black Wire: Connect to GND (Ground).
    • Yellow Wire: Connect to the pulse signal input of your microcontroller.
Wiring diagram for the YF-S201 water flow sensor showing red wire for VCC, black for GND, and yellow for signal output.
Figure 2: Wiring Diagram (Red: VCC, Black: GND, Yellow: Signal)

5. Operating Instructions

The YF-S201 outputs a pulse signal. The frequency of these pulses is proportional to the water flow rate. For users integrating with microcontrollers like Arduino:

  1. Use an interrupt pin on your microcontroller to count the frequency (F) of the output pulses from the yellow wire.
  2. Calculate the water flow rate (Q) in Liters per minute (L/min) using the formula: F (Hz) = 7.5 * Q (L/min).
  3. Therefore, Q (L/min) = F (Hz) / 7.5.

6. Maintenance & Storage

  • Impeller Inspection: Periodically inspect the internal impeller for any buildup of scale or debris, especially when the sensor is used in hard water environments. Clean gently if necessary.
  • Long-Term Storage: If the sensor is not used for a long time, drain any remaining water from the valve body to prevent bacterial growth or internal oxidation.
  • Storage Conditions: Store the sensor in a cool, dry place away from direct sunlight and corrosive vapors when not installed.

7. Troubleshooting

  • No Pulse Output:
    • Verify that the sensor is receiving power (Red wire to 5V-18V DC, Black wire to GND).
    • Check all wiring connections for looseness or damage.
    • Ensure water is flowing through the sensor in the correct direction (indicated by the arrow).
    • Inspect the impeller for any blockages or debris.
  • Inaccurate Flow Readings:
    • Confirm that the connection threads are properly sealed with Teflon tape or a gasket to prevent leaks that could affect readings.
    • Ensure the calculation formula (F = 7.5 * Q) is correctly implemented in your code.
    • Check for any internal debris or scale buildup on the impeller that might impede its rotation.

8. User Tips

  • When connecting, pay close attention to the cable colors: Red for positive voltage, Black for ground, and Yellow for the signal output. This ensures correct operation and prevents damage.
  • For precise measurements, ensure a steady and laminar flow of water through the sensor. Turbulent flow can lead to less accurate readings.

9. Technical Specifications

Parameter Value
Model YF-S201
Working Voltage DC 5V - 18V
Flow Range 1 - 30 L/min
External Thread G 1/2"
Maximum Pressure ≤ 2.0 MPa
Output Signal Pulse (High ≥ 4.6V, Low ≤ 0.5V at 5V supply)
Insulation Resistance ≥ 100 MΩ
Load Capacity ≤ 10mA (DC 5V)
Operating Temperature -25°C to +80°C
Operating Humidity 35%~90%RH (no frost)
Outer Diameter 20mm
Intake Diameter 9mm
Outlet Diameter 12mm
Dimensional diagram of the YF-S201 water flow sensor showing its length, width, and connection sizes.
Figure 3: Dimensional Diagram

10. Disposal & Recycling

This product complies with ROHS standards and contains electronic components that should be recycled responsibly. To prevent environmental impact, do not discard the flow sensor with regular household waste. Please take the device to a local electronic waste collection point or recycling facility for proper material recovery.

A user manual in PDF format is also available for download: YF-S201 User Manual (PDF)

11. Warranty & Support

For warranty information or technical support, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?