Schneider Electric GV2ME Series

Contents

Schneider GV2ME Series Motor Circuit Breaker User Manual

Models: GV2ME14C, GV2ME08C, GV2ME10C, GV2ME16C, GV2ME22C, GV2ME32C

1. Introduction

This manual provides essential information for the safe and effective use of the Schneider GV2ME Series Motor Circuit Breaker. This device is designed for motor start protection and functions as a transfer switch, offering multi-current options to suit various applications. It features a flame-retardant PC material shell, high-quality control buttons, accurate current setting with transparent cover protection, and stable tunnel wiring for secure installation.

Schneider GV2ME Motor Circuit Breaker

Figure 1.1: Schneider GV2ME Motor Circuit Breaker, showing its compact design and control elements.

Play video
Watch video online

Video 1.1: Overview of the Schneider GV2ME Motor Circuit Breaker, demonstrating its features and design.

2. Safety Precautions

Read this manual carefully and follow all safety precautions before moving, installing, operating, and servicing the variable-frequency drive (VFD). Ignoring these precautions may result in physical injury, death, or damage to the devices.

2.1 Safety Definition

  • Danger: Serious physical injury or even death may occur if related requirements are not followed.
  • Warning: Physical injury or damage to the devices may occur if related requirements are not followed.
  • Note: Physical hurt may occur if related requirements are not followed.
  • Qualified electricians: People working on the device should have professional electrical and safety training, certification, and familiarity with all steps and requirements for installation, commissioning, operation, and maintenance.

2.2 Warning Signs

The following warning symbols are used in this manual:

SignNameInstructionAbbreviation
Danger symbolDangerSerious physical injury or even death may occur if related requirements are not followed.Danger abbreviation
Warning symbolWarningPhysical injury or damage to the devices may occur if related requirements are not followed.!
Electrostatic discharge symbolElectrostatic dischargeDamage to the PCBA board may occur if related requirements are not followed.
Hot sides symbolHot sidesSides of the device may become hot. Do not touch.
NotePhysical hurt may occur if related requirements are not followed.Note

2.3 Safety Guidelines

  • Only qualified electricians are allowed to operate on the VFD.
  • Do not carry out any wiring, inspection, or component changes when power is applied. Ensure all input power is disconnected and wait for the designated time (or until DC bus voltage is less than 36V) before working.
  • Do not refit the VFD unauthorizedly; otherwise, fire, electric shock, or other injury may occur.
  • The base of the radiator may become hot during running. Do not touch to avoid injury.
  • Electrical parts inside the VFD are electrostatic. Take measurements to avoid electrostatic discharge.

3. Setup and Installation

This chapter details the mechanical and electrical installation procedures for the GV2ME series VFD.

3.1 Mechanical Installation

3.1.1 Installation Environment

Ensure the installation environment meets the following conditions for optimal performance and longevity:

  • Installation site: Indoor.
  • Temperature: -10°C to +40°C. Derate 1% for every additional 1°C above 40°C. Do not use above 50°C.
  • Humidity: RH ≤ 90%, non-condensing. Max relative humidity ≤ 60% in corrosive air.
  • Storage: -40°C to +70°C.
  • Running environment: Keep away from electromagnetic radiation, contaminative air (corrosive gas, oil mist), direct sunlight, steam, and vibration. Prevent foreign objects (metal powder, dust, oil, water) from entering the VFD.
  • Altitude: Below 1000m for rated power. Derate 1% for every additional 100m above 1000m. For altitudes above 2000m, configure an isolation transformer. For altitudes above 3000m, contact technical support. Do not use above 5000m.
  • Vibration: ≤ 5.8m/s² (0.6g).
  • Installation direction: Upright position for sufficient cooling.

Note: 280 series VFDs should be installed in a clean and ventilated environment. Cooling air must be clean, free from corrosive materials and electrically conductive dust.

3.1.2 Installation Direction and Manner

The VFD can be installed on a wall or in a cabinet, always in an upright position.

Product details showing flame retardant shell, high quality button, accurate current setting, and tunnel wiring.

Figure 3.1: Product details highlighting key features like flame-retardant shell, high-quality buttons, accurate current setting, and stable tunnel wiring.

Wall-mounting steps:

  1. Mark hole locations (refer to Appendix B Dimension Drawings for details).
  2. Fix screws or bolts to marked locations.
  3. Position the drive onto the wall.
  4. Tighten screws securely.

3.1.3 Installation Space

Installation space diagram for VFD

Figure 3.2: Recommended installation space for the VFD, ensuring proper airflow and access. Minimum space of A and B is 100mm.

3.2 Electrical Installation

3.2.1 Connection Diagram of Main Circuit

Ensure all power supplies are disconnected before wiring. Connect input power cables and motor cables with proper techniques to avoid damage.

Main circuit connection diagram for single-phase and three-phase VFD

Figure 3.3: Main circuit connection diagram for both single-phase (220V) and three-phase (380V/220V) VFD configurations. Shows connections for input, output, and optional components like brake resistors, reactors, and filters.

Note: Fuse, DC reactor, braking resistor, input reactor, input filter, output reactor, and output filter are optional parts. Refer to Appendix C "Peripheral options and parts" for detailed information. Remove yellow labels from PB, (+), and (-) terminals before connecting braking resistor cable.

3.2.2 Terminals Figure of Main Circuit

Terminal SignTerminal NameFunction
R/L, S/N, TPower input of the main circuit3-phase/single-phase AC input terminals generally connected with the grid.
U, V, WThe VFD output3-phase AC output terminals generally connected with the motor.
PB, (+)Braking resistor terminalPB and (+) are connected to the external resistor.
Grounding terminalEach machine has a standard PE terminal.

Note: Do not use asymmetrically constructed motor cable. Route motor, input power, and control cables separately. 'T' terminal cannot be wired in single-phase input.

3.2.3 Wiring of Terminals in Main Circuit

  1. Connect the ground wire of the input power cable to the ground terminal (PE) of the VFD. Connect the 3PH input cable to terminals R, S, and T, and fasten them.
  2. Connect the ground wire of the motor cable to the ground terminal of the VFD. Connect the 3PH motor cable to terminals U, V, and W, and fasten them.
  3. Connect the brake resistor and other accessories with cables to their specified positions.
  4. Fasten all cables outside the VFD mechanically, if possible.

3.2.4 Connection Diagram of the Control Circuit

Control circuit connection diagram

Figure 3.4: Control circuit connection diagram, illustrating connections for function input terminals, analog output, open collector output, and RS485 communication.

3.2.5 Wiring Diagram of Control Circuit

Control circuit wiring diagram

Figure 3.5: Detailed control circuit wiring diagram with terminal descriptions.

TerminalDescription
ROARO relay output
ROCContactor capability: 3A/AC250V, 1A/DC30V
+10VLocal power supply +10V
AIAnalog input: 0-10V/0-20mA, 20kΩ voltage input, 500Ω current input. Resolution: 5mV for 10V/50Hz.
24VLocal +24V power supply, 100mA
GND+10V reference zero potential
AOAnalog output: 0-10V or 0-20mA

4. Operating Instructions

This section covers the basic commissioning and keypad operations for the VFD.

4.1 Basic Commissioning

Complete the following steps before actual utilization:

  1. Autotune: Perform dynamic autotune (de-coupled from motor load) or static autotune if dynamic is not possible.
  2. ACC/DEC Time: Adjust acceleration/deceleration time according to the actual load.
  3. Jogging: Commission the device via jogging to check rotation direction. Change motor wiring if direction is incorrect.
  4. Parameters: Set all control parameters before operation.

4.2 Keypad Description

The keypad is used to control 280 series VFDs, read state data, and adjust parameters. An extension cable with a standard RJ45 crystal head can be used for remote keypad placement.

VFD Keypad layout

Figure 4.1: VFD Keypad layout with display and control buttons.

No.NameDescription
1State LEDRUN/TUNE (Off: stopping, Blinking: autotune, On: running), FWD/REV (Off: forward, On: reverse), LOCAL/REMOT (Off: keypad, Blinking: terminals, On: remote), TRIP (On: fault, Off: normal, Blinking: overload pre-alarm).
2Unit LEDIndicates the currently displayed unit (Hz, A, V, RPM, %).
3Code displaying zone5-figure LED display for monitoring data and alarm codes.
4Digital potentiometerCorresponds to AI1.
5ButtonsPRG/ESC (Program/Escape), DATA/ENT (Data/Enter), UP, DOWN, SHIFT, RUN, STOP/RST.

4.3 Keypad Operation

4.3.1 Displayed States

The keypad displays different states: stopping, running, function code editing, and fault alarm.

Keypad displayed states

Figure 4.2: Examples of keypad display in stopping, running, and faulty states.

4.3.2 How to Modify Function Codes

The VFD has a three-level menu structure:

  1. Group number of function code (first-level menu)
  2. Tab of function code (second-level menu)
  3. Set value of function code (third-level menu)

Press PRG/ESC and DATA/ENT to navigate. DATA/ENT saves parameters, PRG/ESC exits without saving.

4.3.3 Password Protection

The VFD offers password protection (P07.00). Set a non-zero number for the password. To clear, set P07.00 to 0.

4.3.4 Viewing VFD State

Group P17 is used for state inspection. Users can directly enter P17 to monitor the VFD's status.

4.4 Function Parameters

The VFD's function parameters are organized into 30 groups (P00-P29). Each group contains specific function codes with 3-level menus. Refer to the detailed tables in the PDF manual for specific parameter settings and their descriptions.

5. Maintenance

This chapter outlines preventive maintenance procedures for the VFD.

5.1 Maintenance Intervals

If installed in an appropriate environment, the VFD requires minimal maintenance. Regular checks include:

  • Ambient environment: Check temperature, humidity, vibration, dust, gas, oil fog, water.
  • Voltage: Ensure main and control circuits are normal.
  • Keypad: Ensure display is clear and characters are visible.
  • Commonly used parts: Check for loose screws, distortion, cracks, damage, or discoloration due to overheating. Ensure no dust or dirtiness.
  • Terminals seat: Check for cracks, discoloration, damage, weeping, or expansion.
  • Filter capacitors: Estimate usage time, measure static capacity.
  • Resistors: Check for replacement/splitting due to overheating, ensure they are not offline.
  • Transformers and reactors: Check for abnormal vibration, noise, or smell.
  • Electromagnetism contactors and relays: Check for vibration noise, loose screws, and good condition.
  • PCB and plugs: Check for smell, discoloration, cracks, damage, distortion, and rust.
  • Cooling fan: Check for abnormal noise, vibration, and ensure no stuff or foreign objection in the fan/air vent.

5.2 Cooling Fan

The VFD's cooling fan has a minimum lifespan of 25,000 operating hours. Actual lifespan depends on usage and ambient temperature. Operating hours can be found via P07.14. Replace the fan if increasing noise from bearings occurs.

WARNING: Read and follow safety precautions. Ignoring instructions may cause physical injury, death, or equipment damage.

Fan Replacement Steps:

  1. Stop the VFD and disconnect from AC power. Wait for designated time.
  2. Lever the fan holder off the drive frame with a screwdriver and lift it slightly.
  3. Disconnect the fan cable.
  4. Remove the fan holder from hinges.
  5. Install new fan holder in reverse order, ensuring consistent wind direction.
  6. Restore power.

5.3 Capacitors

If the VFD has been stored for a long time, DC bus capacitors must be reformed. Refer to the PDF manual for detailed reforming procedures based on storage time.

WARNING: Read and follow safety precautions. Ignoring instructions may cause physical injury, death, or equipment damage.

Change electrolytic capacitors if working hours exceed 35,000. Contact INVT for assistance.

5.4 Power Cable

WARNING: Read and follow safety precautions. Ignoring instructions may cause physical injury, death, or equipment damage.

  1. Stop the drive and disconnect from power line. Wait for designated time.
  2. Check tightness of power cable connections.
  3. Restore power.

6. Troubleshooting

This chapter provides guidance on fault tracking and rectification.

WARNING: Only qualified electricians are allowed to maintain the VFD. Read safety instructions before working.

6.1 Alarm and Fault Indications

Faults are indicated by LEDs. When the TRIP light is on, an alarm or fault message appears on the panel display. Parameters P07.27-P07.32 record the last 6 fault types, and P07.33-P07.56 record operation data for the last 3 fault types. Use this information to identify and correct most alarms and faults.

6.2 Fault Reset

The VFD can be reset by pressing the STOP/RST key on the keypad, via digital input, or by cycling the power. Once the fault is cleared, the motor can be restarted.

6.3 Fault Instruction and Solution

If a VFD fault occurs:

  1. Check the keypad for issues. Contact INVT if necessary.
  2. Check P07 parameters to confirm the fault state.
  3. Refer to the table below for detailed solutions.
  4. Eliminate the fault and seek help if needed.
  5. Clear the fault and reset the VFD to run.
Fault CodeFault TypePossible CauseWhat to Do
OC1Over-current when accelerationAcceleration too fast.Increase ACC time.
OC2Over-current when decelerationDeceleration too fast. Grid voltage too low. Load short-circuited.Increase DEC time. Check input power. Select larger VFD. Check load.
OC3Over-current when constant speed runningLoad transients. Grounding short-circuited. Phase loss. Strong interference.Check load. Check grounding. Check output configuration. Check for interference.
OV1, OV2, OV3Over-voltageAbnormal input voltage. Large energy feedback.Check input power. Check DEC time. Add dynamic braking components.
UVDC bus Under-voltagePower supply voltage too low.Check input power supply line.
OL1, OL2, OL3Motor/VFD OverloadMotor setting rated current incorrect. Motor stall/load too strong. Load too heavy. Motor power too small.Reset rated current. Adjust torque lift. Select bigger VFD. Select proper motor.
OH1, OH2Rectifier/Inverter module overheatedAir duct jam/fan damage. Ambient temperature too high. Overload running too long.Redistribute/dredge wind channel. Lower ambient temperature. Check/reconnect. Change power/power unit/main control panel.
EFExternal faultSI external fault input terminals action.Check external device input.
CECommunication errorBaud rate incorrect. Wiring fault. Address wrong. Strong interference.Set proper baud rate. Check wiring. Set proper address. Improve anti-interference.
EEPEEPROM faultError controlling write/read. Damage to EEPROM.Press STOP/RST. Change main control panel.
PIDEPID feedback faultPID feedback offline/source disappear.Check PID feedback signal/source.
ENDTime reach of factory settingVFD running time above internal setting.Contact supplier to adjust setting.
LLElectronic underload faultVFD reports underload pre-alarm.Check load and underload pre-alarm point.

7. Specifications

7.1 Product Specifications

FunctionSpecification
Input voltage (V)Single-phase 220V (-15%)-240V (+10%), Three-phase 220V (-15%)-240V (+10%), Three-phase 380V (-15%)-440V (+10%)
Input current (A)Refer to 2.5 Rated specifications
Input frequency (Hz)50Hz or 60Hz, Allowed range: 47-63Hz
Output voltage (V)=the input voltage (error < 5%)
Output current (A)Refer to 2.5 Rated specifications
Output power (kW)Refer to 2.5 Rated specifications
Output frequency (Hz)50Hz/60Hz, fluctuation: ±5%
Control modeSVPWM
Maximum output frequency400Hz
Adjustable-speed ratio1:100
Overload capability150% of rated current: 1 minute; 180% of rated current: 10 seconds; 200% of rated current: 1 second
Key functionsStop mode and anti-overtemperature of the bus
Temperature measurement accuracyOvertemperature point ±3°C
Terminal switch input resolution≤ 2ms
Terminal analog input resolution≤ 20mV
Analog input1 input 0-10V/0-20mA
Analog output1 input 0-10V/0-20mA
Digital input5 common input
Digital output1 Y output (commonly used with digital output) and 1 programmable relay output
Communication485 communication
Frequency settingDigital setting, analog setting, multi-step speed setting, PID setting, MODBUS communication setting and so on. Switch between different settings.
Automatic voltage adjustmentKeep output voltage stable when the grid voltage changes
Fault protectionMore than 10 fault protections
Mountable methodWall mountable
Temperature of the running environment-10-50°C. If temperature is above 40°C, derate 1% for every additional 1°C.
CoolingSingle/three-phase 220V 0.2-0.75kW natural cooling; Single/three-phase 220V 1.5-2.2kW, three-phase 380V 0.75-2.2kW
Pollution degree2
Braking unitEmbedded
DC reactorNot optional
Braking resistorOptional and external
EMC filterOptional C3 or C2 filter

7.2 Rated Specifications

ModelOutput power(kW)Input current(A)Output current (A)
Single-phase 220V280-G0.2KW-S20.24.91.6
280-G0.4KW-S20.46.52.5
280-G0.75KW-S20.759.34.2
280-G1.5KW-S21.515.77.5
280-G2.2KW-S22.22410
Three-phase 220V280-G0.2KW-B20.21.91.6
280-G0.4KW-B20.42.72.5
280-G0.75KW-B20.754.94.2
280-G1.5KW-B21.59.07.5
280-G2.2KW-B22.21510
Three-phase 380V280-G0.75KW-B30.753.22.5
280-G1.5KW-B31.54.34.2
280-G2.2KW-B32.27.15.5

7.3 Dimensions

Dimensions are provided in millimeters and inches. Refer to the PDF manual for detailed dimension drawings.

Keypad structure diagram with dimensions

Figure 7.6: Keypad structure diagram with detailed dimensions.

VFD chart with wall mounting dimensions

Figure 7.7: VFD chart showing wall mounting dimensions for various models.

8. User Tips

  • This product falls under the category of Moulded Case circuit breakers, designed for robust motor protection.
  • The model number, such as GV2ME16C, is crucial for identifying specific current ranges and features. Always verify the model number on the nameplate against your requirements.
  • For optimal performance and safety, ensure the VFD is installed in a clean, well-ventilated area, away from direct sunlight and corrosive elements.
  • When setting parameters, especially for frequency and current, always refer to the detailed function code tables in the full PDF manual to ensure correct configuration for your specific motor and load.

9. Technical Data

9.1 Derating in Application

VFD sizing is based on rated motor current and power. The rated current and power of the VFD must be equal to or higher than the motor's. The maximum allowed motor shaft power is limited to 1.5*PN.

The load capacity decreases under certain conditions:

  • Temperature-based derating: For every additional 1°C above 40°C, the rated output current is decreased by 1%.
  • Altitude-based derating: If the altitude is higher than 1000m, the allowable output power is derated.
  • Carrier frequency-based derating: The VFD derates 10% for every additional 1kHz carrier frequency if it exceeds the factory value.

9.2 CE Marking

The CE mark indicates compliance with European Low Voltage (2006/95/EC) and EMC Directives (2004/108/EC).

9.3 EMC Regulations

The EMC Directive defines requirements for immunity and emissions. The product complies with EN 61800-3:2004. Different categories (C1, C2, C3, C4) apply based on voltage, environment, and installation. For domestic environments, supplementary mitigation measures may be required.

10. Communication Protocol

10.1 Modbus Protocol Introduction

The Modbus protocol is a standard software protocol for communication between electrical controllers. It allows devices from different manufacturers to connect to an industrial network for monitoring. The GV2ME VFD uses RTU mode with a 2-wire RS485 physical layer.

10.2 RTU Mode

10.2.1 RTU Communication Frame Format

In RTU mode, messages include a start bit, 7 or 8 data bits, an even/odd check bit (or none), and 1 or 2 end bits. The transmission starts with an idle time (3.5 bytes) followed by slave address, command code, data, and CRC check character.

10.2.2 RTU Communication Frame Error Checkout

Error checking includes bit checkout (even/odd parity) and CRC check for the entire frame to ensure data integrity during transmission.

10.2.3 Command Code: 03H (Read N words)

Used to read data from the VFD. The reading number depends on the "data number" in the command code. Max continuous reading is 16 words.

10.2.4 Command Code: 06H (Write one word)

Used to write data to the VFD. One command can write one data.

10.2.5 Command Code: 08H (Diagnosis)

Used for diagnostic purposes, including returning inquiry information data.

10.2.6 Data Address Definition

Parameter addresses occupy 2 bytes. The high byte represents the function code group number, and the low byte represents the number after the radix point. Note that some parameters cannot be changed in running state or at all, and P29 group is factory reserved.

10.2.7 Fieldbus Ratio Values

Communication data is expressed in hexadecimal. Non-integer values are magnified to integers for transmission. The fieldbus ratio value is determined by the radix point in the setting range or default value.

10.2.8 Fault Message Response

If a communication fault occurs, the VFD returns a fault response message with a specific code and meaning (e.g., Illegal command, Illegal data address, Illegal value, Operation failed, Password error, Data frame error, Written not allowed, Parameter cannot be changed during running, Password protection).

For more detailed information on the Modbus protocol, including specific command formats and examples, please refer to the full PDF manual.

11. Warranty and Support

11.1 Product and Service Inquiries

Should you have any queries about the product, contact your local INVT office. Provide the model and serial number of your product. You can visit www.invt.com to find a list of INVT offices.

11.2 Feedback on INVT VFD Manuals

Your comments on our manuals are welcome. You can directly contact online service personnel or choose to use the 'Contact Us' option on the INVT website to provide feedback.

11.3 Online Document Library

You can find manuals and other product documents in PDF format on the Internet. Visit the INVT website and navigate to 'Service and Support' > 'Data Download'.

A PDF version of this user manual is available for download: Download User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.