The VISHRT 4.3 Inch IPS Industrial Endoscope Camera is a portable, high-quality, multifunctional detection system designed for non-destructive testing in complex industrial environments. Featuring a full-color IPS screen, it offers powerful video recording capabilities, allowing users to capture 2.0MP images (JPG) and 1080P HD videos (AVI) for detailed inspections. This manual provides essential information for the safe and effective use of your endoscope.

VISHRT 4.3 Inch IPS Industrial Endoscope Camera main unit with coiled cable

Figure 1: Main unit of the VISHRT Industrial Endoscope Camera, showcasing its 4.3-inch IPS screen and 1080P capability.

Safety Warnings and Precautions

  • Warning! Read all safety warnings and instructions before using this product. Failure to follow the warnings and instructions may result in product damage.
  • Do not disassemble the product by yourself to avoid malfunctions. Please contact customer service if needed.
  • Do not use in high-temperature environments to avoid damage to the lens. The product operating temperature is -10°C to 50°C.
  • If the endoscope produces mist due to weather, turn on the image and run it for about 20 minutes until the image is clear. Store in a dry place when not in use.
  • The lens will become hot during use, especially when the LED light is brightest. This is normal and will not affect operation or service life.
  • Prevent objects and liquids from entering the device. Liquids will damage the electronic components and circuit boards.
  • Industrial endoscopes are not suitable for medical use.

Product Overview

Main Unit Features

  1. Menu/Back Button
  2. Up/Rotate Image Button
  3. Down/Rotate Image Button
  4. OK Button
  5. Take Pictures/Videos Button
  6. LED Brightness Adjustment Dial
  7. Power On/Off Button
  8. TF Card Slot
  9. Work Indicator Light
Close-up of the 4.3 Inch Color Explosion-proof HD LCD Screen

Figure 2: The 4.3-inch Color Explosion-proof HD LCD Screen provides clear, true-color restoration for detailed viewing.

Lens Types and Protection

The endoscope supports various lens configurations to suit different inspection needs, including single, dual, and triple lens options with varying diameters and cable lengths. The device is also equipped with silicone anti-fall protection for enhanced durability.

Lens Size Comparison showing various endoscope lens types

Figure 3: Comparison of available lens sizes and configurations: 3.9mm, 5.5mm, 8mm, Dual 5.5mm, Dual 8mm, and Triple 8mm.

Image demonstrating Silicone anti-fall protection

Figure 4: The device features silicone anti-fall protection, enhancing its durability in rugged environments.

Setup

1. Inserting the TF Card

  • Ensure the device is powered off before inserting the TF card.
  • Locate the TF card slot on the side of the main unit.
  • Confirm the front of the TF card before inserting.
  • Insert the TF card gently until it clicks into place. Do not use excessive force when inserting or unplugging the TF card to prevent damage to the card slot structure.

2. Connecting the Camera Cable

  • The endoscope features a pluggable structure for convenient replacement of camera cables.
  • Align the USB connector of the camera cable with the USB port on the top of the main unit.
  • Gently push the connector in until it is firmly seated.
Image illustrating the Pluggable structure for convenient replacement

Figure 5: The pluggable structure allows for easy and convenient replacement of the camera cable.

Operating Instructions

1. Power On/Off

  • Press and hold the Power On/Off button (7) on the side of the device to turn it on or off.

2. Menu Navigation

  • Menu/Return Button (1): Press briefly to enter the menu interface.
  • Use the Up/Rotate Image Button (2) and Down/Rotate Image Button (3) to navigate through menu options.
  • OK Button (4): In the menu interface, short press 'OK' to confirm a selection.
  • To exit the menu, press the Menu/Return button again.

3. Taking Pictures and Recording Videos

  • Take Picture: Short press the Take Pictures/Videos Button (5) to capture an image.
  • Record Video: Long press the Take Pictures/Videos Button (5) to start video recording. Short press it again to stop recording.

4. Image Rotation and Camera Switching

  • Image Rotation: In the image interface, use the Up/Rotate Image Button (2) and Down/Rotate Image Button (3) to rotate the displayed image.
  • Switch Camera (for dual/triple lens): Long press the 'OK' button (4) to switch between front camera and side camera views.

5. Adjusting LED Brightness

  • Use the LED Brightness Adjustment Dial (6) on the side of the main unit to increase or decrease the illumination from the camera's LED lights. This is useful for optimizing visibility in dark environments.
Image showing LED Brightness Adjustable feature

Figure 6: The LED brightness can be adjusted using the dial, providing optimal illumination in various conditions.

6. Product Demonstration Video

Video 1: A demonstration of the endoscope's basic functions, including power-on, LED adjustment, image clarity test, and waterproof capabilities.

Maintenance

  • Cleaning the Lens: After use, especially in dirty or wet environments, gently wipe the camera lens with a soft, dry cloth. For stubborn dirt, a slightly damp cloth can be used, followed by a dry one. Ensure no liquid enters the lens assembly.
  • Storage: When not in use, store the endoscope in a dry place, away from direct sunlight and extreme temperatures.
  • Handling Mist: If mist appears on the lens due to weather conditions, turn on the device and let it run for about 20 minutes until the image clears.

Troubleshooting

  • Mist on Lens: If the endoscope produces mist because of weather conditions, turn on the image and run it for about 20 minutes until the image is clear.
  • Lens Gets Hot: The lens will become hot during use, especially when the LED light is the brightest. This situation is normal and will not affect the operation and service life of the endoscope.
  • General Malfunctions: If you experience any other malfunctions or unusual behavior, do not attempt to disassemble or repair the product yourself. Please contact customer service for assistance.

Specifications

FeatureSpecification
Screen Type4.3 Inch IPS Display
Camera Resolution2.0 Megapixels (1920*1080)
Video Resolution1280*720
Viewing Angle70°
Best Focal Length (Front Lens)50-80mm
Best Focal Length (Side Lens)20-50mm (for dual/triple camera)
Lens Diameter Options3.9mm, 5.5mm, 8mm
Wire TypeHard Wire
Battery Capacity2000mAh
Working Time2.5 hours
Charging Time2 hours
Working Temperature0°C - 45°C
Waterproof RatingIP67 (for camera probe)
Port TypeType-C charging port, TF memory card slot
CertificationsCE, FCC, RoHS

User Tips

  • The model number for this endoscope is QWE-741, also referred to as T19 4.3 Inch Endoscope in some contexts.
  • This device falls under the category of industrial endoscopes, designed for visual inspection in hard-to-reach areas.

Statement of Compliance

Disclaimer:

⚠️ Camera products can only be used for the purposes permissible under the applicable law and regulations. Misuse of the product for any illegal activities is strictly forbidden. Please comply with the applicable laws and regulations in your country/area.

Warranty and Support

This product is manufactured under strict quality control standards. For any warranty claims, technical support, or service inquiries, please refer to your purchase documentation or contact the seller directly. Keep your proof of purchase for any warranty-related services.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.