1. Introduction
The DATOUBOSS Pure Sine Wave Inverter is a high-performance power conversion device designed to transform 12V DC power from a battery into stable 220V AC power, suitable for a wide range of electronic devices and appliances. Utilizing advanced MCU microprocessor-controlled SPWM technology, it delivers a pure sine wave output, ensuring compatibility with sensitive electronics and providing a clean, reliable power source. This inverter is ideal for various applications, including automotive use, home backup power, camping, caravans, and powering tools or office equipment.


2. Product Features
- Pure Sine Wave Output: Adopts MCU microprocessor-controlled SPWM technology for pure sine wave output and waveform, ensuring compatibility with all types of loads, including sensitive electronics.
- Dynamic Current Loop Control: Unique dynamic current loop control technology guarantees reliable and stable operation of the inverter.
- Strong Load Adaptability: Capable of handling various load types, including inductive loads (e.g., motors, refrigerators), capacitive loads, resistive loads, and mixed loads.
- Comprehensive Protection: Features perfect protection functions against input over-voltage, under-voltage, overload, overheat, and output short circuit.
- Clear LCD Display: Equipped with an LCD liquid crystal display that provides real-time status information at a glance.
- Efficient Design: The single-channel multi-group transformer series innovation uses a single-transformer vertical multi-layer copper ring superimposed winding method, which reduces copper loss and magnetic loss, reduces heat, and improves efficiency. Work efficiency ranges from 80% to 95%.
- Optimized Heat Dissipation: Centralized dual air ducts are used to dissipate heat evenly from left to right, reducing the temperature of MOS tubes and improving conversion efficiency.
- Enhanced Safety: Dual current detection in the front and back stages provides multiple protections, ensuring efficient and stable operation without causing damage to power supply equipment and load equipment due to a single electronic component failure.
3. Display Instructions
The inverter's LCD provides critical operational information:

- Power-on Display: Shows the current ambient temperature when the inverter starts up.
- High-Voltage Protection: Indicates when the input voltage exceeds the applicable range, triggering high-voltage protection.
- Low-Voltage Protection: Indicates when the input voltage is lower than the applicable range, triggering low-voltage protection and stopping the output.
- High Temperature Protection: Alerts if the inverter cannot operate normally due to excessive ambient temperature, activating high-temperature protection.
- Short-Circuit Protection: Signals a fault in the connected electrical appliance or load circuit, indicating a short-circuit condition.
- Overload Protection: Activates if the connected load power exceeds the inverter's rated value.
4. Specifications
| Parameter | DN-022 (1000W) | DN-023 (1500W) |
|---|---|---|
| Output Power | 1000W | 1500W |
| Display | LCD liquid crystal display | |
| Input Voltage | 12V / 24V | |
| Input Range | 12V (10-15V) | 24V (20-30V) |
| Low Voltage Protection | 10V | |
| Overvoltage Protection | 15V | |
| No-load Current | 0.7A | 0.8A |
| Output Voltage | 230V | |
| Output Frequency | 50Hz / 60Hz | |
| Output Waveform | Pure Sine Wave | |
| Overheating Protection | 80°C ± 5°C | |
| Conversion Efficiency | ≥90% | |
| Cooling Method | Built-in air-cooled | |
| Overall Dimension | 31 x 12 x 6.4 cm | |
| Product Weight | 1.9kg | 2.3kg |
5. Installation Requirements
Proper installation is crucial for the safe and efficient operation of your inverter. Please follow these guidelines:
- Environment: Install the inverter in a dry, clean, and well-ventilated area. Avoid enclosed spaces that can trap heat.
- Working Temperature: Ensure the operating environment temperature is between -20°C and 80°C.
- Battery Connection: Connect the inverter to a battery with a matching voltage (12V for DN-022, 24V for DN-023). Ensure the battery is fully charged before use.
- Cabling: Always use the original connecting cables provided with the inverter. These cables are designed for the correct current and voltage requirements.
- Ventilation: Do not cover the inverter. Ensure that the cooling fans and air vents are unobstructed to allow for proper heat dissipation.


6. Operating Instructions
To operate the inverter:
- Ensure the inverter is correctly connected to a compatible battery using the provided cables. Connect the red cable to the positive (+) terminal of both the inverter and the battery, and the black cable to the negative (-) terminal of both.
- Ensure no AC loads are connected to the inverter's output socket.
- Switch the inverter's power switch to the 'ON' position. The LCD display will illuminate, showing the current status.
- Connect your AC appliances to the inverter's AC output socket.
- If using the USB port, connect your USB-powered device to the USB 5V 2.1A port.
- Monitor the LCD display for any warning indicators (e.g., low voltage, overload).
- When finished, switch off the inverter before disconnecting any loads or the battery.
7. Caution and Safety
- Professional Installation: Installation and commissioning of this equipment should only be carried out by professional electrical maintenance personnel who are familiar with the structure of the unit and the dangers of operation.
- Water Hazard: Keep the inverter away from water. Avoid any water dripping onto the machine or gradual exposure to moisture. Never plug or unplug the inverter with wet hands.
- Flammable Materials: Keep the inverter away from flammable substances or places where flammable gases are accumulated.
- High Voltage: High voltage is dangerous. Do not attempt to open or service the machine yourself.
- Power Off When Not in Use: Always switch off the machine when it is not in use to prevent accidental activation and conserve battery power.
- Ventilation: Ensure adequate airflow around the inverter. Do not block the fan or ventilation openings.
8. User Tips
- Load Capacity: While the inverter is rated for continuous power, it's always a good practice to keep the continuous load slightly below the maximum rated power (e.g., 1400W for a 1500W inverter) for optimal performance and longevity.
- Inductive Loads: This pure sine wave inverter is effective for inductive loads like refrigerators. Ensure the inverter's peak power rating can handle the appliance's startup surge.
- Idle Current: Be aware of the inverter's idle current (e.g., 0.5A for the 1000W model). This is the power consumed when no load is connected, which can slowly drain your battery over time.
- Battery Terminals: Ensure battery terminals are securely attached to the inverter. Loose connections can lead to poor performance or damage.
- Ventilation: Good ventilation is key to preventing overheating, especially under heavy loads.
9. Troubleshooting
If you encounter issues with your inverter, consider the following common problems and solutions:
- No Output Power:
- Check if the inverter's power switch is in the 'ON' position.
- Verify that the battery connections are secure and correct (positive to positive, negative to negative).
- Ensure the battery voltage is within the acceptable input range (10-15V for 12V systems, 20-30V for 24V systems). - Low Output Voltage:
- Check the battery charge level. A low battery can result in reduced output voltage.
- Reduce the connected load. Overloading can cause voltage drops. - Overload Protection Triggered:
- The inverter will shut down if the connected load exceeds its rated power. Disconnect some appliances to reduce the load.
- Some appliances (like motors) have a high startup surge. Ensure the inverter's peak power rating can handle this. - Overheat Protection Triggered:
- This occurs if the inverter's internal temperature becomes too high. Ensure the inverter is in a well-ventilated area and its cooling fans are not blocked.
- Reduce the connected load to decrease heat generation. - Short-Circuit Protection Triggered:
- Disconnect all loads from the inverter. Check each appliance and its connecting cables for any short circuits or faults. - Constant Random Restarts or Rapid Voltage Drops:
- This can indicate an unstable power source or an issue with the inverter itself.
- Verify the battery is fully charged and healthy.
- Check all connections for looseness or corrosion.
- Ensure the load is not intermittently exceeding the inverter's capacity.
- If the problem persists, consult the official user manual or contact customer support.
10. Warranty and Support
For detailed warranty information, additional instructions, or technical support, please refer to the official user manual PDF or contact the manufacturer directly.
Official User Manual (PDF): View User Manual (PDF)
Contact Information:
Mobile/WeChat/Whatsapp/LINE: +8613783531376
Email: Manager@xdatou.com