Gaqqee JQ-006

Contents

Gaqqee JQ-006 10-in-1 Water Quality Tester Pen Instruction Manual

Model: JQ-006

1. Introduction

This manual provides instructions for the safe and effective use of your Gaqqee JQ-006 10-in-1 Water Quality Tester Pen. Please read this manual thoroughly before operation and keep it for future reference.

The device is a multi-functional water quality test pen designed to accurately measure various parameters of water, ensuring the health of drinking water for your family. It is lightweight, portable, and features a dust-proof and splash-proof design (IP65 waterproof level).

2. Package Contents

Please check the package contents upon unboxing:

  • 10-in-1 Water Quality Tester Pen (JQ-006)
  • Instruction Manual
  • Calibration Powder (pH 4.01, pH 6.86, pH 9.18, ORP Buffer Powder - if Type B)
  • (Note: Batteries are not included in Model A. Model B includes batteries.)
Package contents of the water quality tester pen, showing the device, instruction manual, and calibration powders.

Image: Contents of the product package, including the JQ-006 tester, instruction manual, and various calibration powders.

Water quality tester pen in its retail box, with a note that batteries are not included.

Image: The JQ-006 water quality tester pen in its retail packaging. Note: The product does not come with a battery; customers who need a battery should purchase it by themselves.

3. Product Overview

The JQ-006 is a 10-in-1 water quality test pen. It features an ergonomic design for comfortable handling, a dual-display screen for simultaneous readings, and durable, long-lasting keys. The electrode head and batteries are replaceable for extended service life.

Diagram of the JQ-006 water quality tester showing its components: battery compartment, power button, hold/temp button, mode/cal button, electrode protection cover, glass electrode, temperature sensor, TDS electrodes, and EC electrodes.

Image: Product structure diagram of the JQ-006. Key components include the battery compartment, power button, temperature/lock key, menu/calibration key, electrode protection cover, glass electrode, temperature sensor, TDS electrodes, and EC electrodes. It uses 3*1.5V button batteries.

Close-up of the JQ-006 water quality tester showing ergonomic design, replaceable accessories, dual screen display, and long-lasting keys.

Image: Features of the JQ-006 tester, highlighting its ergonomic design, replaceable battery and electrode head, simultaneous display of pH and temperature, and durable buttons.

Image showing the high-sensitivity electrode tip of the JQ-006 water quality tester.

Image: Close-up of the built-in high-sensitivity electrode tip, which adopts a high-sensitivity glass electrode and an anti-rust platinum electrode.

4. Setup

4.1 Battery Installation

  1. Unscrew the top cap of the device to access the battery compartment.
  2. Insert three 1.5V button batteries, ensuring correct polarity.
  3. Securely screw the cap back on.

4.2 Initial Preparation

  1. Remove the electrode protection cover from the bottom of the device.
  2. Rinse the electrodes with distilled water and gently blot dry with a clean tissue.

4.3 Calibration

Calibration is crucial for accurate readings. Perform calibration regularly, especially before first use, after long periods of inactivity, or if readings appear inaccurate.

pH Calibration:

  1. Prepare pH 4.01, pH 6.86, and pH 9.18 buffer solutions according to the calibration powder instructions (usually dissolving in 250ml of distilled water).
  2. Turn on the meter.
  3. Press the "MODE/CAL" button until "CAL" appears on the screen.
  4. Immerse the electrode in the pH 6.86 buffer solution. The meter will automatically recognize the solution and calibrate. Wait for the reading to stabilize.
  5. Rinse the electrode with distilled water.
  6. Immerse the electrode in the pH 4.01 buffer solution. The meter will calibrate.
  7. Rinse the electrode with distilled water.
  8. Immerse the electrode in the pH 9.18 buffer solution. The meter will calibrate.
  9. After successful calibration, the meter will return to measurement mode.

ORP Calibration:

  1. Prepare the ORP buffer powder solution (e.g., 256mV at 25°C).
  2. Immerse the electrode in the ORP buffer solution.
  3. Follow the device's specific calibration steps for ORP, usually involving pressing and holding the "MODE/CAL" button until calibration is complete.

Note: Refer to the detailed instructions provided with your calibration powders for precise preparation and usage.

5. Operating Instructions

5.1 Basic Operation

  1. Press the power button (Power button icon) to turn on the device.
  2. Immerse the electrode into the water sample up to the maximum immersion level.
  3. Gently stir the meter and wait for the reading to stabilize.
  4. Press the "HOLD/TEMP" button to freeze the current reading on the display. Press again to release.
  5. To switch between different measurement modes (pH, EC, TDS, SALT, ORP, H2, S.G, MΩ, Nutrient Fertility), press the "MODE/CAL" button repeatedly.
  6. Press the power button to turn off the device.
Play video
Watch video online

Video: Demonstration of unboxing and basic function switching on the JQ-006 water quality tester.

Multi-function display of the JQ-006 water quality tester showing various parameters like pH, EC, TDS, Salt, ORP, H2, S.G, and MΩ.

Image: The multi-function display of the JQ-006, illustrating how different parameters (pH, EC, TDS, SALT, ORP, H2, S.G, Nutrient Solution Fertility, MΩ) can be switched and viewed.

5.2 Temperature Compensation

The device features automatic temperature compensation (ATC) between 0-60°C. This ensures accurate readings even with varying water temperatures. The temperature will have a certain impact on pH measurement; if accuracy requirements are high, the impact will be greater, so a high-precision pH meter with intelligent temperature compensation function is very necessary.

Diagram illustrating automatic temperature compensation with automatic cooling and warm-up for accurate readings at 25°C.

Image: Illustration of the automatic temperature compensation function, showing how the device adjusts for temperatures that are too low or too high to provide accurate readings, aiming for a reasonable temperature of 25°C.

5.3 Understanding Readings

  • pH Value: Measures acidity or alkalinity (0-14). Water that is too acidic or too alkaline has adverse effects on the human body.
  • TDS (Total Dissolved Solids): Indicates water purity (0-200,000 ppm).
  • EC (Electrical Conductivity): Measures the ability of water to conduct electricity (0-200,000 µS/cm).
  • Salinity: Measures salt content (0-20%).
  • ORP (Oxidation-Reduction Potential): Reflects the ecological environment of aquatic systems (±1999 mV).
  • H2 (Hydrogen-rich): Measures hydrogen content (0-2400 ppb).
  • S.G (Seawater Specific Gravity): Measures density of seawater (1.000-1.222).
  • MΩ (Resistivity): Digital representation of a solution's ability to conduct current, often used for water purity (50 Ω – 20 MΩ).
  • Nutrient Fertility: Indicates nutrient concentration (0-3).
pH value chart showing acidic, neutral, and alkaline ranges with corresponding pH levels and examples.

Image: pH value reference chart, indicating acidic (4.0-6.6), neutral (7.0-7.8), and alkaline (8.5-10.0) ranges. The pH detection range is 0.00-14.00.

TDS numerical reference table showing purity levels from high purity (0-20ppm) to affecting health (1000 or more ppm).

Image: TDS numerical reference table, categorizing water purity from High Purity (0-20ppm) to Affect Health (1000 or more ppm). TDS detection range is 0-200,000ppm.

Water conductivity chart showing EC values for different water types from ultra-pure water to brine.

Image: Water conductivity chart (EC: 0-200,000 µS/cm) showing typical values for various water types: Ultra-pure Water (0.055 µS/cm), Distilled Water (0.5 µS/cm), Mountain Spring Water (1 µS/cm), Tap Water (50-800 µS/cm), Drinking Water (1055 µS/cm), Clear Water (56 µS/cm), Brine (100 µS/cm).

ORP value reference table showing ranges for aerobic and anaerobic respiration and microbial species.

Image: ORP value reference table, indicating ranges for aerobic (300-400mV) and anaerobic (<100mV, >100mV, -200-300mV) respiration types and corresponding microbial species.

Image showing the JQ-006 testing hydrogen-rich water with a measuring range of 0-2400 ppb.

Image: Hydrogen-rich water quality testing. Experiments show that hydrogen water can delay oxidation. Measuring range: 0-2400 PPb. Regularly drinking hydrogen-rich water can delay aging.

Image showing the JQ-006 measuring seawater specific gravity (S.G) in various environments like aquaculture, sea water, swimming pools, and aquariums.

Image: Seawater specific gravity (S.G) measurement. The density of seawater is usually 1.02-1.07, with dissolved salts varying by about 3.5% on average. S.G range: 1.000-1.222, applicable to aquaculture, sea water, swimming pools, and aquariums.

Image showing the JQ-006 measuring salinity in food, applicable to hotels, restaurants, family meals, and food processing.

Image: Salinity value detection. Detects salinity in food to protect human health. Suitable salinity for humans is 0.900%. Edible salt range: 0.01-25.00%, applicable to hotels, restaurants, family meals, and food processing.

Image showing the JQ-006 measuring nutrient concentration for plant growth, with ranges for low, moderate, and high concentrations.

Image: Nutrient concentration measurement. One test to know. Ranges: 0-1 (low, not suitable for plant growth), 1-3 (moderate, more suitable for plant growth), 3 (too high, need to add water to dilute).

Image showing the JQ-006 performing MΩ detection, representing the ability of a solution to conduct current, indicating water purity.

Image: MΩ detection. MΩ is a digital representation of a solution's ability to conduct current, often representing total concentration of ions or salt content, or water purity. Detection range: 50 Ω – 20 MΩ.

6. Maintenance

6.1 Cleaning

  • After each use, rinse the electrode thoroughly with distilled water to remove any residue.
  • Do not use abrasive materials or harsh chemicals to clean the device.
  • Gently blot the electrode dry with a clean, soft tissue.

6.2 Storage

  • Always replace the electrode protection cover when the meter is not in use to prevent damage and keep the electrode moist.
  • Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.
  • If storing for extended periods, remove the batteries to prevent leakage.

6.3 Electrode Replacement

The electrode head is replaceable. If the electrode becomes damaged or its performance degrades significantly, it can be replaced to extend the life of the device.

6.4 Battery Replacement

When the battery indicator shows low power, replace the three 1.5V button batteries as described in the Setup section.

7. Troubleshooting

ProblemPossible CauseSolution
Meter does not turn onDead batteries; Incorrect battery installationReplace batteries; Check battery polarity
Inaccurate readings / Cannot calibrateElectrode dirty; Calibration expired; Damaged electrode; Incorrect calibration procedureClean electrode; Recalibrate with fresh solutions; Replace electrode; Follow calibration steps carefully
Slow response timeElectrode dry; Electrode agingEnsure electrode is kept moist; Replace electrode
Display flickering or unstableLow battery; Electrical interferenceReplace batteries; Move away from other electronic devices

8. User Tips

  • Regular Calibration: Users have reported issues with calibration. Always ensure you use fresh calibration solutions and follow the calibration steps precisely for accurate results. If you cannot calibrate, try cleaning the electrode thoroughly and using new buffer solutions.
  • Electrode Care: Keep the electrode moist by replacing the protective cap after each use. A dry electrode can lead to slow response times and inaccurate readings.
  • Battery Check: If the device behaves erratically or doesn't turn on, check and replace the batteries first.
  • Alkalinity Measurement: While this device measures pH, it does not directly measure alkalinity. For pool owners with salt chlorinators, you would typically use a separate test kit for alkalinity.

9. Specifications

ParameterMeasurement Range
Product Name10-in-1 Water Quality Tester Pen
Model NumberJQ-006
pH Value0–14
TDS Value0–200,000 ppm
EC Value0–200,000 µS/cm
Salinity0–20%
ORP (Redox Potential)±1999 mV
H2 (Hydrogen-rich)0–2400 ppb
S.G (Seawater Specific Gravity)1.000–1.222
Temperature0–60°C
Nutrient Solution Fertility0–3
MΩ (Resistivity)50 Ω – 20 MΩ
Battery3 x 1.5V Button Cells
Product Dimensions185 x 37 x 24 mm
Waterproof RatingIP65
Display TypeDIGITAL (with backlight)
Diagram showing the dimensions of the JQ-006 water quality tester: 18.5cm length, 3.7cm top width, 2.4cm bottom width.

Image: Product parameters showing dimensions: 18.5cm/7.3in (length), 3.7cm/1.5in (top width), 2.4cm/0.94in (bottom width).

Image showing the bright LCD screen of the JQ-006 water quality tester, highlighting its clarity and eye-friendliness.

Image: The large LCD backlit screen is clearer and more eye-friendly, making clear reading easier.

Image showing the dust and water repellent design of the JQ-006 water quality tester, complying with IP65 waterproof rating and featuring a built-in waterproof rubber ring.

Image: Dust and water repellent design. Complies with IP65 waterproof rating, featuring a built-in waterproof rubber ring.

10. Warranty and Support

For warranty information and technical support, please refer to the seller's policy or contact the point of purchase. Keep your purchase receipt as proof of purchase.

© 2024 Gaqqee. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.