1. Introduction
This manual provides instructions for the safe and effective use of your Gaqqee JQ-006 10-in-1 Water Quality Tester Pen. Please read this manual thoroughly before operation and keep it for future reference.
The device is a multi-functional water quality test pen designed to accurately measure various parameters of water, ensuring the health of drinking water for your family. It is lightweight, portable, and features a dust-proof and splash-proof design (IP65 waterproof level).
2. Package Contents
Please check the package contents upon unboxing:
- 10-in-1 Water Quality Tester Pen (JQ-006)
- Instruction Manual
- Calibration Powder (pH 4.01, pH 6.86, pH 9.18, ORP Buffer Powder - if Type B)
- (Note: Batteries are not included in Model A. Model B includes batteries.)

Image: Contents of the product package, including the JQ-006 tester, instruction manual, and various calibration powders.

Image: The JQ-006 water quality tester pen in its retail packaging. Note: The product does not come with a battery; customers who need a battery should purchase it by themselves.
3. Product Overview
The JQ-006 is a 10-in-1 water quality test pen. It features an ergonomic design for comfortable handling, a dual-display screen for simultaneous readings, and durable, long-lasting keys. The electrode head and batteries are replaceable for extended service life.

Image: Product structure diagram of the JQ-006. Key components include the battery compartment, power button, temperature/lock key, menu/calibration key, electrode protection cover, glass electrode, temperature sensor, TDS electrodes, and EC electrodes. It uses 3*1.5V button batteries.

Image: Features of the JQ-006 tester, highlighting its ergonomic design, replaceable battery and electrode head, simultaneous display of pH and temperature, and durable buttons.

Image: Close-up of the built-in high-sensitivity electrode tip, which adopts a high-sensitivity glass electrode and an anti-rust platinum electrode.
4. Setup
4.1 Battery Installation
- Unscrew the top cap of the device to access the battery compartment.
- Insert three 1.5V button batteries, ensuring correct polarity.
- Securely screw the cap back on.
4.2 Initial Preparation
- Remove the electrode protection cover from the bottom of the device.
- Rinse the electrodes with distilled water and gently blot dry with a clean tissue.
4.3 Calibration
Calibration is crucial for accurate readings. Perform calibration regularly, especially before first use, after long periods of inactivity, or if readings appear inaccurate.
pH Calibration:
- Prepare pH 4.01, pH 6.86, and pH 9.18 buffer solutions according to the calibration powder instructions (usually dissolving in 250ml of distilled water).
- Turn on the meter.
- Press the "MODE/CAL" button until "CAL" appears on the screen.
- Immerse the electrode in the pH 6.86 buffer solution. The meter will automatically recognize the solution and calibrate. Wait for the reading to stabilize.
- Rinse the electrode with distilled water.
- Immerse the electrode in the pH 4.01 buffer solution. The meter will calibrate.
- Rinse the electrode with distilled water.
- Immerse the electrode in the pH 9.18 buffer solution. The meter will calibrate.
- After successful calibration, the meter will return to measurement mode.
ORP Calibration:
- Prepare the ORP buffer powder solution (e.g., 256mV at 25°C).
- Immerse the electrode in the ORP buffer solution.
- Follow the device's specific calibration steps for ORP, usually involving pressing and holding the "MODE/CAL" button until calibration is complete.
Note: Refer to the detailed instructions provided with your calibration powders for precise preparation and usage.
5. Operating Instructions
5.1 Basic Operation
- Press the power button (
) to turn on the device. - Immerse the electrode into the water sample up to the maximum immersion level.
- Gently stir the meter and wait for the reading to stabilize.
- Press the "HOLD/TEMP" button to freeze the current reading on the display. Press again to release.
- To switch between different measurement modes (pH, EC, TDS, SALT, ORP, H2, S.G, MΩ, Nutrient Fertility), press the "MODE/CAL" button repeatedly.
- Press the power button to turn off the device.
Video: Demonstration of unboxing and basic function switching on the JQ-006 water quality tester.

Image: The multi-function display of the JQ-006, illustrating how different parameters (pH, EC, TDS, SALT, ORP, H2, S.G, Nutrient Solution Fertility, MΩ) can be switched and viewed.
5.2 Temperature Compensation
The device features automatic temperature compensation (ATC) between 0-60°C. This ensures accurate readings even with varying water temperatures. The temperature will have a certain impact on pH measurement; if accuracy requirements are high, the impact will be greater, so a high-precision pH meter with intelligent temperature compensation function is very necessary.

Image: Illustration of the automatic temperature compensation function, showing how the device adjusts for temperatures that are too low or too high to provide accurate readings, aiming for a reasonable temperature of 25°C.
5.3 Understanding Readings
- pH Value: Measures acidity or alkalinity (0-14). Water that is too acidic or too alkaline has adverse effects on the human body.
- TDS (Total Dissolved Solids): Indicates water purity (0-200,000 ppm).
- EC (Electrical Conductivity): Measures the ability of water to conduct electricity (0-200,000 µS/cm).
- Salinity: Measures salt content (0-20%).
- ORP (Oxidation-Reduction Potential): Reflects the ecological environment of aquatic systems (±1999 mV).
- H2 (Hydrogen-rich): Measures hydrogen content (0-2400 ppb).
- S.G (Seawater Specific Gravity): Measures density of seawater (1.000-1.222).
- MΩ (Resistivity): Digital representation of a solution's ability to conduct current, often used for water purity (50 Ω – 20 MΩ).
- Nutrient Fertility: Indicates nutrient concentration (0-3).

Image: pH value reference chart, indicating acidic (4.0-6.6), neutral (7.0-7.8), and alkaline (8.5-10.0) ranges. The pH detection range is 0.00-14.00.

Image: TDS numerical reference table, categorizing water purity from High Purity (0-20ppm) to Affect Health (1000 or more ppm). TDS detection range is 0-200,000ppm.

Image: Water conductivity chart (EC: 0-200,000 µS/cm) showing typical values for various water types: Ultra-pure Water (0.055 µS/cm), Distilled Water (0.5 µS/cm), Mountain Spring Water (1 µS/cm), Tap Water (50-800 µS/cm), Drinking Water (1055 µS/cm), Clear Water (56 µS/cm), Brine (100 µS/cm).

Image: ORP value reference table, indicating ranges for aerobic (300-400mV) and anaerobic (<100mV, >100mV, -200-300mV) respiration types and corresponding microbial species.

Image: Hydrogen-rich water quality testing. Experiments show that hydrogen water can delay oxidation. Measuring range: 0-2400 PPb. Regularly drinking hydrogen-rich water can delay aging.

Image: Seawater specific gravity (S.G) measurement. The density of seawater is usually 1.02-1.07, with dissolved salts varying by about 3.5% on average. S.G range: 1.000-1.222, applicable to aquaculture, sea water, swimming pools, and aquariums.

Image: Salinity value detection. Detects salinity in food to protect human health. Suitable salinity for humans is 0.900%. Edible salt range: 0.01-25.00%, applicable to hotels, restaurants, family meals, and food processing.

Image: Nutrient concentration measurement. One test to know. Ranges: 0-1 (low, not suitable for plant growth), 1-3 (moderate, more suitable for plant growth), 3 (too high, need to add water to dilute).

Image: MΩ detection. MΩ is a digital representation of a solution's ability to conduct current, often representing total concentration of ions or salt content, or water purity. Detection range: 50 Ω – 20 MΩ.
6. Maintenance
6.1 Cleaning
- After each use, rinse the electrode thoroughly with distilled water to remove any residue.
- Do not use abrasive materials or harsh chemicals to clean the device.
- Gently blot the electrode dry with a clean, soft tissue.
6.2 Storage
- Always replace the electrode protection cover when the meter is not in use to prevent damage and keep the electrode moist.
- Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.
- If storing for extended periods, remove the batteries to prevent leakage.
6.3 Electrode Replacement
The electrode head is replaceable. If the electrode becomes damaged or its performance degrades significantly, it can be replaced to extend the life of the device.
6.4 Battery Replacement
When the battery indicator shows low power, replace the three 1.5V button batteries as described in the Setup section.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Meter does not turn on | Dead batteries; Incorrect battery installation | Replace batteries; Check battery polarity |
| Inaccurate readings / Cannot calibrate | Electrode dirty; Calibration expired; Damaged electrode; Incorrect calibration procedure | Clean electrode; Recalibrate with fresh solutions; Replace electrode; Follow calibration steps carefully |
| Slow response time | Electrode dry; Electrode aging | Ensure electrode is kept moist; Replace electrode |
| Display flickering or unstable | Low battery; Electrical interference | Replace batteries; Move away from other electronic devices |
8. User Tips
- Regular Calibration: Users have reported issues with calibration. Always ensure you use fresh calibration solutions and follow the calibration steps precisely for accurate results. If you cannot calibrate, try cleaning the electrode thoroughly and using new buffer solutions.
- Electrode Care: Keep the electrode moist by replacing the protective cap after each use. A dry electrode can lead to slow response times and inaccurate readings.
- Battery Check: If the device behaves erratically or doesn't turn on, check and replace the batteries first.
- Alkalinity Measurement: While this device measures pH, it does not directly measure alkalinity. For pool owners with salt chlorinators, you would typically use a separate test kit for alkalinity.
9. Specifications
| Parameter | Measurement Range |
|---|---|
| Product Name | 10-in-1 Water Quality Tester Pen |
| Model Number | JQ-006 |
| pH Value | 0–14 |
| TDS Value | 0–200,000 ppm |
| EC Value | 0–200,000 µS/cm |
| Salinity | 0–20% |
| ORP (Redox Potential) | ±1999 mV |
| H2 (Hydrogen-rich) | 0–2400 ppb |
| S.G (Seawater Specific Gravity) | 1.000–1.222 |
| Temperature | 0–60°C |
| Nutrient Solution Fertility | 0–3 |
| MΩ (Resistivity) | 50 Ω – 20 MΩ |
| Battery | 3 x 1.5V Button Cells |
| Product Dimensions | 185 x 37 x 24 mm |
| Waterproof Rating | IP65 |
| Display Type | DIGITAL (with backlight) |

Image: Product parameters showing dimensions: 18.5cm/7.3in (length), 3.7cm/1.5in (top width), 2.4cm/0.94in (bottom width).

Image: The large LCD backlit screen is clearer and more eye-friendly, making clear reading easier.

Image: Dust and water repellent design. Complies with IP65 waterproof rating, featuring a built-in waterproof rubber ring.
10. Warranty and Support