1. Important Safety Notice
Please read the following guidelines carefully before using this product for underwater activities. Your continued use confirms that you have read, understood, and agree to abide by these safety precautions, and that you voluntarily assume all associated risks.
1.1. Diver Certification & Training Requirements
- Users must possess a valid diving certification (e.g., PADI Open Water Diver Certification) or have completed equivalent professional dive training.
- You must have both the practical skills and theoretical knowledge necessary for underwater emergency response and comply with all applicable national and regional diving safety regulations.
1.2. Pre-Dive Equipment Inspection
- Before each dive, review this manual thoroughly and conduct a complete equipment check.
- Verify that the scuba regulator is functioning properly, the cylinder is intact with sufficient gas, and the secondary regulator is operating correctly.
- Do not use any equipment that appears faulty or compromised.
1.3. Complementary Equipment Requirement
The scuba breathing apparatus is only one component of a complete dive system. It must be used in conjunction with essential gear such as a dive knife, dive computer or watch, spare cylinder, and dive suit. Please consult a certified diving instructor to tailor your equipment configuration to your specific diving needs.
1.4. Environmental Condition Assessment
Prior to entering the water, assess current weather and sea conditions, including wind strength, wave activity, and visibility. Refrain from diving if conditions are adverse, such as during strong winds or unstable seas, to ensure optimal safety.
1.5. User Eligibility & Physical Condition
- This product is intended for individuals 18 years of age and older.
- Do not dive if you are underage or if you have consumed alcohol, smoked, are excessively fatigued, suffering from a cold, or engaging in breath-holding dives.
- It is essential that you are in optimal physical and mental condition before every dive.
1.6. Buddy System Requirement
Regardless of the type of dive or the environment, always adhere to the buddy system. Solo diving is strictly prohibited to ensure immediate assistance in case of an emergency.
Always follow these procedures diligently to ensure your safety and the safety of your dive partners.
2. Setup Instructions
2.1. Components of the 0.5L Scuba Tank
Familiarize yourself with the parts included in your kit:

Figure 1: Exploded view of 0.5L Scuba Tank components
- 0.5L Mini Scuba Cylinder
- Regulator Mouthpiece
- All-in-One Demand Regulator
- Valve Seat Gasket
- Steel Retaining Ring
- O-Ring Seal
2.2. 0.5L Scuba Tank Assembly Instructions

Figure 2: Step-by-step assembly of the 0.5L Scuba Tank
- Attach the breathing mouthpiece securely to the regulator.
- Remove the plastic cap from the regulator.
- Position the internal parts as shown in Figure 2. Tip: Ensure the side marked "To Bottle" is facing outward.
- Connect the regulator to the scuba tank.
- Fill the scuba tank with compressed air (refer to Section 3.1 for detailed inflation procedures).
- Press the valve briefly to check for proper airflow before use.
Important: During assembly, carefully check the placement of all sealing rings and internal components. Missing or incorrect installation may lead to air leakage.
2.3. Snorkel Mask Components

Figure 3: Components of the full-face snorkel mask
- Full-Face Snorkel Mask
- Action Camera Mount
- Dry-Top Valve
- Breathing Tube
- 360° Swivel Joint
- Mask Adapter
2.4. Mask Installation & 0.5L Scuba Tank Connection Steps

Figure 4: Steps for installing the snorkel mask and connecting the scuba tank
- Install the snorkel tubes onto the mask.
- Connect the tubes securely to the mask body.
- If needed, attach the action camera mount.
- Remove the breathing mouthpiece from the scuba tank regulator.
- Twist and connect the mask adapter to the scuba tank's regulator.
- Attach the assembled scuba tank to the dual-tube snorkel mask.
- Assembly complete - ready for use.
2.5. Manual Air Pump Installation & Testing
The manual air pump is an optional accessory for refilling your scuba tank.
- Attach the handle to the pump using the included screws.
- Install the pressure gauge and securely tighten it using the multifunction wrench.
- Connect the high-pressure hose and built-in air filter to the pump. Use the wrench to ensure all connections are tight.
- Insert the test air plug into the end of the hose.
- Tighten the pressure relief valve completely by turning it clockwise.
- Pump several strokes while observing the pressure gauge. If the needle rises, the pump is functioning correctly.
- Loosen the pressure relief valve slowly by turning it counterclockwise to release pressure. Wait until the gauge needle drops to zero, then remove the air plug.
3. Operating Instructions
3.1. Scuba Tank Inflation Procedure
Critical Safety Notice: Pressure release is absolutely essential. Always use the pressure relief valve to release built-up air before detaching any components. Failure to release pressure beforehand may result in sudden air bursts, leading to injury or equipment damage.
3.1.1. Inflating with a Manual Air Pump
- Connect the high-pressure hose to the scuba tank via the quick-connect fitting. Ensure the connection is tight and secure.
- Before starting to pump, tighten the pressure relief valve completely to prevent air leakage.
- Begin pumping. Continue until the pressure shown on the gauge reaches 3000 PSI (200 Bar). The inflation process will take time, as you are compressing air into a small tank at high pressure.
- After inflation, slowly release pressure by loosening the relief valve. Wait until the gauge pointer returns to zero.
- Disconnect the high-pressure hose from the scuba tank only after the pressure has been fully released.
Tip: The pump's outer tube may become hot during extended use. Please avoid direct contact to prevent burns.
3.1.2. Inflating from a Large Scuba Tank (via Refill Adapter)
- Connect the large scuba tank to the scuba regulator.
- Ensure the pressure relief valve and the scuba regulator exhaust valve are securely tightened.
- Attach the fill adapter to the small tank's fill port.
- Slowly open the fill valve to begin charging the small tank. Monitor the pressure and stop filling once it reaches 3000 PSI (200 BAR).
- After filling is complete, close the fill valve and gradually open the pressure relief valve to safely release excess pressure.
- Disconnect the small tank, completing the refill process.
Note: Always follow proper safety procedures when handling high-pressure gas systems.
3.1.3. Filling Process Using an Electric Compressor
- Connect one end of the fill hose to the compressor outlet.
- Attach the other end to the scuba cylinder's fill port.
- Tighten the compressor's bleed valve.
- Set the desired fill pressure using the adjustment knob (do not exceed 3000 PSI/200 BAR).
- Turn on the compressor to begin filling.
- Once filling is complete, slowly open the bleed valve to release pressure.
- Disconnect the cylinder from the fill hose.
Warning: Always release pressure using the bleed valve (Step 6) before disconnecting the cylinder. Skipping this step may cause dangerous sudden pressure release!
3.2. Breathing Procedure
- Place the mouthpiece between your teeth and form a tight lip seal.
- Breathe slowly and evenly—do not hold your breath.
3.3. Pressure-Gauge Monitoring & Ascent
- Continuously monitor the high-pressure gauge.
- When the gauge pointer enters the red warning zone (≤ 50 bar), begin a controlled ascent to the surface.
- Only refill the cylinder once back on the surface and depressurized.
3.4. Operational Limits
- Maximum Depth: 10m (33 ft)
- Maximum Working Pressure: 3000 PSI / 200 bar / 20 MPa
4. Maintenance
4.1. Post-Dive Maintenance
Immediately after diving, rinse the equipment thoroughly with fresh water at least five times. Prevent seawater from entering the intake ports and valve assemblies. Residual seawater can lead to the formation of corrosive salt and alkaline deposits, which may damage the valves and obstruct the pipelines.
4.2. Post-Use Maintenance
- Rinse the cylinder exterior and regulator thoroughly with fresh water; remove salt residue.
- Completely vent all remaining air by pressing the purge button.
- Unscrew and separate the regulator from the cylinder.
- Store the cylinder in an unpressurized state.
4.3. Storage Recommendations
- When not in regular use, store the portable mini scuba regulator and cylinder at a temperature between 0°C and 30°C (32°F to 90°F).
- Store in a cool, dry location away from direct sunlight.
- Do not leave in vehicle trunks or high-temperature environments. Extended storage in extreme high or low temperatures may cause deterioration of internal components (e.g., O-rings) leading to air leakage, and promote mold growth on ancillary parts.
- To protect the regulator and cylinder from debris, cover the regulator inlet during storage.
5. Troubleshooting Guide
Safety Note: Always wear eye protection and gloves when pressurizing or testing the cylinder.
5.1. Leak Detection Methods
- Visual Inspection: Examine all threaded connections, O-rings, and sealing faces for scratches, deformation, or debris.
- Listen Test: Pressurize the cylinder to working pressure (3000 PSI). In a quiet room, place your ear close to each interface and listen for a faint "hiss."
- Soap-Bubble Test: Apply a film of soapy water or commercial leak-detection fluid to each suspect area. Look for continuous bubbling.
- Underwater Submersion Test: Fully pressurize the assembled unit, then immerse it in clean water. Rotate each component slowly and watch for streams of bubbles pinpointing the leak location.
5.2. Common Leaks and Repairs
5.2.1. Breathing-Valve Head - Cylinder Interface Leak
| Issue | Possible Causes | Repair Steps |
|---|---|---|
| Leak at cylinder connection |
|
|
5.2.2. Fill-Port Inlet Leak (Port #1)
Symptom: Air escaping from the fill-port male adapter base.
Repair Procedure: Unscrew the male fill adapter from the fill port. Remove, clean, or replace the small O-ring at its base. Reinstall the adapter and tighten.
5.2.3. Fill-Port Threaded Connection Leak (Port #2)
Symptom: Leakage at the fill-port thread interface.
Repair Procedure: Unscrew the entire fill-port assembly from the valve. Remove and replace the O-ring seal.
5.2.4. Pressure-Gauge Threaded Connection Leak (Port #3)
Symptom: Air escaping from the gauge threads.
Repair Procedure: Tighten the gauge at its threaded connection—apply firm, controlled torque.
5.2.5. Over-Sensitive Demand Mechanism (Purge Button) Leak
Cause: Sensitivity adjuster set too steeply, allowing constant micro-leaks through the purge.
Adjustment Steps:
- Depress the purge button fully to bleed down internal pressure.
- Remove the valve head's top cover to expose the demand-adjustment screw.
- Using the mini-wrench provided, adjust the screw in small increments (≈¼ turn at a time):
- Clockwise → increases sensitivity
- Counterclockwise → decreases sensitivity
- Reassemble, repressurize, and test. Repeat until leak stops.
- If uncertain, perform an underwater submersion test to locate residual leaks and readjust as needed.
5.2.6. Control-Stem (Adjustment Lever) Leak
Cause: Dust or debris lodged on the stem.
Repair Procedure: Remove the safety (anti-burst) screw. Extract the control stem assembly and clean all surfaces. Reinstall the stem and safety screw to hand-tight torque.
5.2.7. Safety (Anti-Burst) Screw Leak
Cause: Screw has loosened.
Repair Procedure: Slightly back off the screw (counterclockwise), then re-tighten firmly (clockwise) to restore seal.
5.3. Final Verification After Repairs
- Pressure-Hold Test: After all repairs, pressurize the cylinder to 3000 PSI and let sit for 5-10 minutes. Confirm the gauge reading remains stable.
- Functional Breathing Test: Simulate several inhale/exhale cycles to ensure the demand and purge functions operate smoothly without leaks.
Important: Always conduct all disassembly and reassembly procedures in a zero-pressure state and use only breathing-grade replacement parts supplied with the unit.
6. Specifications

Figure 5: Overview of the 0.5L Scuba Tank and its main parts

Figure 6: Diagram illustrating air flow within the scuba tank system
| Feature | Specification |
|---|---|
| Material | Aviation-Grade Aluminum (DOT/CE Certified) |
| Capacity | 0.5 Liters (Approx. 30.5 cu in) |
| Working Pressure | 20MPa / 200BAR / 3000PSI |
| Product Weight | 1.3kg (Approx. 2.87 lbs) |
| Recommended Diving Depth | Up to 5 meters (Approx. 16.4 ft) |
| Air Supply Duration | Approx. 5-10 minutes (Varies depending on individual lung capacity, diving depth, and water temperature) |
| Filling Methods |
|
7. Air Transportation
If you need to bring the equipment on board an aircraft, please comply with the Transportation Security Administration (TSA) regulations. Ensure that the cylinder is completely empty, with no residual gas, when inspected by security personnel. Follow these packing guidelines:
- Fully depressurize the portable mini scuba regulator by emptying the air from the cylinder.
- Unscrew the first-stage regulator counterclockwise from the cylinder and pack it separately. Retain the O-ring and gasket on the corresponding threaded connection.
- Place the regulator in the equipment case, keeping it clean, and cover the threaded end with a dust cap to prevent the loss of O-rings, gaskets, or other components.
- If small parts become dislodged during transport, ensure that the O-rings, gaskets, and reassembly sequence are maintained correctly.
8. Warranty & Support
8.1. Warranty Period
Our products are covered by a one-year warranty from the date of delivery. Beyond this period, repairs due to product failure will be subject to a parts charge.
8.2. Warranty Limitations
Repairs or replacements under warranty are limited to defects resulting from manufacturing faults and are not applicable to issues caused by misuse, accidental damage, or unauthorized modifications. Consumable components, such as seals, are not covered by warranty; however, replacement services are available to ensure your diving equipment maintains optimal performance.
8.3. After-Sales Support
If you encounter any product issues (such as air leakage or difficulty inflating), please don't hesitate to contact us via email at sign2@goyojo.com. We'll be more than happy to provide technical support or send you replacement parts free of charge to help resolve the problem.
During the free warranty period, the Company reserves the right to refuse service or levy material and service charges at its discretion if any of the following conditions occur:
- Damage caused by using the product in a manner that does not meet the applicable requirements, standards, or specifications.
- Damage resulting from improper use, inadequate storage, unauthorized disassembly, or maintenance by the user.
- Damage caused by natural disasters (e.g., earthquakes, floods, lightning strikes) or external incidents (e.g., fire, building collapse).
- Damage due to the use of non-company products.
- Failure or damage caused by improper relocation, transportation, or storage.
- Inadequate packaging or shipping, for which the Company will not be responsible for any damage or loss incurred during transit.
A detailed user manual is available for download at: GOYOJO 0.5L Mini Scuba Tank PDF Manual
9. User Tips
- Pump Necessity: This scuba tank requires a pump or a refill adapter to be filled. Ensure you have a compatible filling method (manual pump, large scuba tank adapter, or electric compressor) before use.
- Usage Duration: The 0.5L tank typically provides 5-10 minutes of air supply, depending on individual lung capacity, diving depth, and water temperature. It is ideal for assisting with snorkeling or as an emergency backup for diving.
- Filling Time: Filling the tank with a manual pump can take a significant amount of time due to the high pressure involved.
- Leak Checks: Always perform thorough leak checks, especially between the valve and the bottle, after assembly and before each use, to ensure safety and proper function.
- Spare Parts: Keep spare O-rings and seals handy, as these are consumable parts that may need replacement over time.