1. Introduction
This sound level meter is designed to measure the sound level of various environments, including factories, workshops, schools, residences, offices, and traffic areas. It is also suitable for applications in noise engineering, product quality control, and health prevention. Additionally, it can measure ambient temperature and humidity.
Before using the instrument, please read this manual carefully and save it for future use.
2. Safety Information and Considerations
- Wind blowing across the microphone can increase noise measurement. Use the supplied windscreen to cover the microphone when applicable.
- Calibrate the instrument before each use if possible, especially if the meter has not been used for a long period of time.
- Do not store or operate the instrument in areas of high humidity or extreme temperatures.
- Keep the meter and microphone dry.
- Avoid severe vibration.
- Remove the battery when the meter is to be stored for long periods of time to prevent leakage.
3. Product Overview
3.1 Components
3.2 Display Screen Symbols
| Symbol | Description | Symbol | Description |
|---|---|---|---|
| ن | Auto power off | H | Data hold |
| MAX | Maximum value | MIN | Minimum value |
| °C | Celsius | RH% | Humidity unit |
| °F | Fahrenheit | Low battery | |
| FAST | Quick response | SLOW | Slow response |
| dB | Decibel unit | A | A weighted |
| C | C weighted |
4. Specifications
| Parameter | Value |
|---|---|
| Display Screen | LCD display |
| Range | 30-130dBA or 30-130dBC (for model B) |
| Frequency | 30Hz-8KHz |
| Dynamic Range | 50 dB |
| Accuracy | ±1.5dB (94dB@1KHz), ±5dB (94dB@8KHz) |
| Frequency weighting | A weighting, C weighting (for model B) |
| Time weighting | FAST: 125ms, SLOW: 1sec |
| Microphone | Electret condenser |
| Temperature Range | -20.0°C to 60.0°C (-4.0°F to 140.0°F) |
| Temperature Accuracy | 0.0°C-45.0°C (32°F-113°F): ±1.0°C/2.0°F; Others: ±1.5°C/3.0°F |
| Humidity Range | 0.0%~99.9%RH |
| Humidity Accuracy | 20%-80%: ±5.0RH; Others: ±6.0RH |
| Operating conditions | 0~50°C, <80%RH, altitude less than 2000m |
| Storage conditions | -10~50°C |
| Auto Power Off | 10 minutes (can be disabled) |
| Power | 3 x 1.5V AAA batteries |
| Battery Included | No |
| Is Smart Device | No |
| Hign-concerned Chemical | None |
| Certification | CE, FCC |
5. Setup
5.1 Battery Installation
- Unscrew the battery cover.
- Open the battery compartment.
- Remove any old batteries if present.
- Install three new 1.5V AAA batteries correctly, observing the positive and negative marks on the bottom of the battery compartment.
- Reinstall the battery cover and fasten the screws to secure it.
5.2 Initial Power On
After installing the batteries, press the Power button to turn on the device. The meter will immediately begin displaying sound pressure level, ambient temperature, and humidity.
6. Operation
6.1 Measurement
- Open the protection cover of the microphone.
- Press the Power button to turn on the device.
- After the power is turned on, the meter will start to display the sound pressure level reading.
- Hold the meter and let the microphone face the sound source to be measured.
- Read the measured value from the display.
- Press the Power button to turn off the device.
6.2 Fast/Slow Time Weighted Selection
Use the F/S button to select 'FAST' (125 ms) or 'SLOW' (1 sec) time weighting. The selected mode ('FAST' or 'SLOW') will appear on the display.
- FAST response: Captures noise peaks and fast-emerging noise.
- SLOW response: Monitors sound sources with consistent noise sound pressure levels and averages out rapidly changing noise.
6.3 Data Hold
Press the H button to enable the data retention function. Press the H button again to turn off the data hold function and return to normal measurement.
6.4 Backlight
Press the H/☀ button and hold it for more than 2 seconds to enable or disable the backlight function.
6.5 MAX/MIN Function
Press the MAX/MIN button to enable the maximum and minimum functions. Then press the MAX/MIN button to display the maximum and minimum values. Press and hold for about 2 seconds to return to normal measurement function.
6.6 Temperature Unit Selection
Press the °C/°F button to shift the temperature unit between Celsius (°C) or Fahrenheit (°F).
6.7 A/C Weighted Selection (for model B only)
Press the °C/°F button and hold for about 2 seconds to switch between A or C weighting.
6.8 Automatic Power Off
When the instrument is turned on, the Auto Power Off symbol is displayed. The automatic shutdown function is on by default. If there is no operation within 10 minutes, the meter will automatically shut down.
To disable the automatic shutdown function, press and hold the Power button before turning on the instrument. Then press the Power button to turn on the power of the instrument, release the Power button after turning on the instrument, and the automatic shutdown symbol will not be displayed.
To restore the automatic shutdown function after it has been disabled, restart the instrument.
7. Maintenance
7.1 Battery Replacement
When the meter displays the low battery symbol, please replace the batteries promptly:
- Unscrew the battery cover and open the battery compartment.
- Remove the old batteries.
- Install new 1.5V AAA batteries, ensuring correct polarity.
- Reinstall the battery cover and fasten the screws.
7.2 Cleaning
To avoid damaging the case, do not use corrosive agents or solvents to clean the instrument. Wipe the shell regularly with a damp cloth and mild detergent.
7.3 Storage
If the meter is to be stored for long periods, remove the batteries to prevent leakage and damage. Store the device in a dry environment, away from extreme temperatures and humidity.
8. Troubleshooting
If the device does not power on, check the battery installation and ensure the batteries are new or fully charged. If readings appear inconsistent, ensure the microphone is clear of obstructions and consider calibrating the instrument if possible. For persistent issues, refer to the official support channels.
9. User Tips
No specific user tips were available from reviews or Q&A content for this product at this time. Always ensure the sponge ball is properly placed over the microphone for accurate readings, especially in windy conditions.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the GVDA Official Store or refer to the documentation provided with your purchase. You can also find additional information in the official user manual PDF available at: GVDA Sound Level Meter User Manual (PDF).