1. Introduction
The Diymore KWS-302 series is a multi-function AC energy power meter designed for monitoring various electrical parameters. It features a high-definition color screen that displays voltage, current, power, energy consumption (KWH), timing, frequency, power factor, and temperature. The device is suitable for standard DIN rail installation and offers power-off memory protection. Specific models (KWS-302WF) include WiFi connectivity for remote monitoring and control, as well as undervoltage and overvoltage protection.
2. Key Features
- Simple installation with low power consumption.
- High-definition color display for clear data visualization.
- 8-in-1 display: Voltage (V), Current (A), Power (KW), Energy (KWH), Timing (Hours), Frequency (Hz), Power Factor (PF), and Temperature (°C).
- Power-off memory function to retain data.
- Standard DIN rail mounting for convenient installation without screws (snap fastening).
- KWS-302WF Model Only: WiFi mobile remote control for unlimited distance monitoring and control via a smartphone application.
- KWS-302WF & KWS-302L Models Only: Undervoltage and Overvoltage protection.
3. Specifications
The following table details the technical specifications for the KWS-302 series energy meters:
| Parameter | KWS-302WF | KWS-302L | KWS-302 |
|---|---|---|---|
| Input Voltage | AC170-300V | AC170-300V | AC170-300V |
| Current Range | 0-63A | 0-63A | 0-63A |
| Power Range | 0-17KW | 0-17KW | 0-17KW |
| Timing Range | 0-999 Hours | 0-999 Hours | 0-999 Hours |
| Electricity Range | 0-9999 KWH | 0-9999 KWH | 0-9999 KWH |
| Temperature Range | -20 to 150°C | -20 to 150°C | -20 to 150°C |
| Frequency Range | 50-60HZ | 50-60HZ | 50-60HZ |
| Power Factor | 0.00-1.00PF | 0.00-1.00PF | 0.00-1.00PF |
| Blackout Memory | Yes | Yes | Yes |
| Undervoltage Protection | Yes | Yes | No |
| Overvoltage Protection | Yes | Yes | No |
| WiFi Functionality | Yes | No | No |
Dimensions: Approximately 78.8mm (Length) x 65.6mm (Width) x 45mm (Height). Refer to the dimension diagram for detailed measurements.
4. Package Contents
Upon opening the package, you should find the following item:
- Voltage and Current Meter (KWS-302 series) x 1
5. Setup and Installation
5.1. DIN Rail Installation
The KWS-302 series meters are designed for standard DIN rail installation. Simply snap the device onto the DIN rail. No screws or additional fasteners are required for mounting.
5.2. Wiring Instructions
Ensure all power is disconnected before wiring. Connect the input (IN) and output (OUT) terminals as shown in the diagrams below. The 'N' terminal is for Neutral, and 'L' is for Live.
5.3. Temperature Sensor Connection (If applicable)
If your model includes a temperature sensor, connect it to the dedicated NTC interface on the device. The sensor allows for ambient temperature monitoring.
5.4. WiFi Pairing (KWS-302WF Model Only)
For the KWS-302WF model, you can connect the device to your WiFi network for remote control and monitoring. Download the "Smart Life APP" or "Doodle Smart App" on your mobile phone and follow the in-app instructions for WiFi pairing.
6. Operation
6.1. Display Interface
The meter features a high-definition color screen that displays various electrical parameters simultaneously. The display is designed for ease of operation and clear visualization of data.
6.2. Mobile Remote Control (KWS-302WF Model Only)
For the KWS-302WF model, once paired with the mobile app, you can remotely monitor and control the device from anywhere with a signal. This allows for convenient management of your electrical system.
7. Maintenance
- Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
- Avoid exposing the device to extreme temperatures or humidity.
- Ensure all wiring connections remain secure. Periodically check for any loose connections.
- Do not attempt to open or repair the device yourself, as this may void the warranty and pose a safety risk.
8. Troubleshooting
- No Display/Power: Check the input voltage supply. Ensure wiring is correct and secure.
- Incorrect Readings: Verify wiring connections. Ensure the current is within the specified range (0-63A).
- WiFi Connection Issues (KWS-302WF Only):
- Ensure your router is within range and broadcasting a 2.4GHz WiFi signal.
- Check that the device is in pairing mode as per the app instructions.
- Restart the device and your router, then attempt pairing again.
- Overvoltage/Undervoltage Protection Triggered (KWS-302WF & KWS-302L Only): If the display shows an alert for overvoltage (HI) or undervoltage (LO), check your power supply for stability. The device will automatically cut off power to protect connected appliances. Power will be restored once the voltage returns to a safe range.
- Power Failure Memory: The device is designed to retain data even after a power outage. If data is lost, ensure the device is functioning correctly and contact support if the issue persists.
9. User Tips
- For accurate temperature readings, ensure the temperature sensor (if included) is placed in an area representative of the ambient temperature you wish to monitor.
- When using the WiFi remote control, regularly update the mobile application to ensure optimal performance and access to the latest features.
- Consider using the multiplayer control feature (KWS-302WF) if multiple users need to monitor or manage the energy meter.
10. Warranty and Support
For detailed warranty information, technical support, or service inquiries, please refer to the official product documentation or contact Diymore customer service. A user manual in PDF format is available for download at this link.