XY-T01 Digital Temperature Controller Module User Manual

Model: XY-T01 | Brand: ERIKOLE

1. Introduction

The ERIKOLE XY-T01 is a versatile digital temperature controller module designed for precise temperature management in various applications. It supports both heating and refrigeration modes, features a clear digital display, and offers a wide temperature control range. This manual provides detailed instructions for its installation, operation, and maintenance.

Front view of the XY-T01 Digital Temperature Controller Module with sensor.

Figure 1: Front view of the XY-T01 Digital Temperature Controller Module with sensor.

2. Safety & Warnings

Read all instructions before use. Failure to follow these instructions may result in damage to the product or personal injury.

  • Warning: Keep the device and its cord out of reach of children under 3 years old.
  • Keep away from children unless supervised by an adult.
  • Do not use this product for purposes other than its intended use.
  • Inspect the product before each use; do not use if damaged.
  • Follow installation and operation guidelines to avoid injury.
  • Electrical products: Do not expose to water or moisture.

3. Specifications

FeatureDescription
Brand NameERIKOLE
Model NumberXY-T01
Power SupplyDC 6-30V
Temperature Control Range-50°C to 110°C
Temperature Control Accuracy0.1°C
Display TypeDIGITAL
Display Size1.9 Inches & Under
Measure TypeK
Cable Length1m
ScrewM12*1.5
CertificationCE
OriginMainland China
StyleEmbedded
Is Smart DeviceNo
UseIndoor
Battery IncludedNo
Package Dimensions (L x W x H)11cm x 13cm x 3cm
Package Weight0.06 kg
Image illustrating the temperature control range (-50°C to 110°C) and control accuracy (0.1°C) of the module.

Figure 2: Temperature control range and accuracy.

4. Product Overview

The XY-T01 module features a compact design with an integrated display, control buttons, and terminal blocks for easy connection. Below is a diagram highlighting the key components:

Detailed front view of the XY-T01 module with labeled components including power supply, relay output, buzzer, buttons (Stop, Set, Up, Down), display, and sensor connection.

Figure 3: Labeled components of the XY-T01 module.

5. Setup

5.1 Power Supply Connection

Connect the DC 6-30V power supply to the designated terminals on the module. Ensure correct polarity: '+' for positive and '-' for negative.

5.2 Sensor Connection

Connect the temperature sensor to the NTC terminals. The module uses a K-type sensor.

5.3 Load Connection

The module's relay output can control either AC or DC loads. Refer to the appropriate wiring diagram below for your application.

5.3.1 AC Load Wiring (e.g., AC 220V)

Wiring diagram for connecting an AC 220V load to the XY-T01 module. Shows power input (DC 6.0-30V) and relay output to the AC load.

Figure 4: Wiring diagram for AC 220V load.

5.3.2 DC Load Wiring (e.g., DC 6-30V)

Wiring diagram for connecting a DC load to the XY-T01 module. Shows power input (DC 6.0-30V) and relay output to the DC load.

Figure 5: Wiring diagram for DC load.

6. Operating Instructions

6.1 Product Functions

  • Heating Mode ('H'): When the current temperature is less than or equal to (Set Temperature - Backlash Temperature), the relay activates, and heating equipment begins to work. When the current temperature is greater than or equal to the Set Temperature, the relay disconnects, and heating equipment stops.
  • Refrigeration Mode ('C'): When the current temperature is greater than or equal to (Set Temperature + Backlash Temperature), the relay activates, and refrigeration equipment begins to work. When the current temperature is less than or equal to the Set Temperature, the relay disconnects, and refrigeration equipment stops.
  • High Temperature Alarm ('ALA'): If the current temperature reaches or exceeds the Alarm Temperature, the system triggers an audible and visual alarm and disconnects the relay. Pressing any key will stop the alarm.
  • Delay Start ('OPH'): After a normal heating or refrigeration cycle completes, the system initiates a delay timer (T). The next cycle can only begin after T is greater than or equal to the set OPH duration.
  • Temperature Correction Function ('OFE'): Allows for calibration of the measured temperature (range: -10.0 to 10.0°C). The corrected temperature is calculated as: Measured Temperature + Calibration Value.
  • Parameter Remote Read/Set: Parameters such as setting temperature, backlash temperature, and temperature correction can be configured via UART communication.
  • Real-time Temperature Report: If enabled, the product transmits temperature data to the terminal via UART at 1-second intervals for data collection.
  • Relay Enable (Default Enabled): If the relay is disabled, it remains disconnected regardless of temperature conditions.
  • Restore Factory Settings: Simultaneously press the 'STOP' and 'SET' keys for more than 3 seconds to restore the module to its factory default settings.

6.2 Setting Procedures

6.2.1 Working Mode Setting / Backlash Temperature

  1. In the running interface, short press the SET key to enter the Quick Setting interface.
  2. After entering the Quick Setup interface, use the UP or DOWN keys to switch between parameters.
  3. Use the UP or DOWN keys to modify the parameter value. Short press for incremental changes, long press for faster changes.
  4. Long press the SET key for more than 3 seconds, or wait for 6 continuous seconds without any key operation, to exit the Quick Setting interface and save the parameters.

6.2.2 Alarm Temperature / Delay Start / Temperature Correction

  1. In the operating interface, long press the SET key for more than 3 seconds to enter the Parameter Setting interface.
  2. Within the Parameter Setting interface, short press the SET key to cycle through the parameters (ALA, OPH, OFE).
  3. Use the UP or DOWN keys to modify the parameter value. Short press for incremental changes, long press for faster changes.
  4. Long press the SET key for more than 3 seconds, or wait for 6 continuous seconds without any key operation, to exit the Parameter Setting interface and save the parameters.

6.2.3 How to Turn On/Off High Temperature Alarm (ALA)

Enter the Parameter Setting interface (long press SET for 3s). Navigate to the ALA parameter. Short press the STOP button to toggle the high temperature alarm function on or off. If the alarm function is off, '----' will be displayed for ALA as a reminder.

6.2.4 How to Turn On/Off Delay Start (OPH)

Enter the Parameter Setting interface (long press SET for 3s). Navigate to the OPH parameter. Short press the STOP button to toggle the delay start function on or off. If the delay start function is off, '----' will be displayed for OPH as a reminder.

6.3 Serial Control (MCU UART)

The module supports serial communication for remote control and data acquisition. Use the following communication standards:

  • Communication Standards: 9600bps
  • Data Bits: 8
  • Stop Bits: 1
  • CRC: None
  • Flow Control: None

The following table lists the available commands:

CMDDescription
startStart temperature report
stopStop temperature report
readRead parameters setting
onRelay Enable
offRelay Disable
S:XXXSetting Temperature (-50 ~ -01, 00.0~99.9, 100~110)
B:XX.XSet Backlash Temperature (00.0~30.0)
OFE:XX.XTemperature Calibration (-10.0 ~ 10.0)
ALA:XX.XAlarm Temperature (-50.0 ~ 110.0)
OPH:XXXXDelay Start (0 ~ 9999 Minutes)

Figure 6: Serial Control Commands.

7. Maintenance

  • Keep the module clean and free from dust and debris. Use a soft, dry cloth for cleaning.
  • Avoid exposing the module to extreme temperatures, humidity, or corrosive environments.
  • Regularly check all wiring connections to ensure they are secure.

8. Troubleshooting

  • Display shows 'h': This indicates that the OPA (Delay Start) function is active. The system is currently in a delayed state before initiating the next heating or refrigeration cycle.
  • Image showing the display interface when the OPA (Delay Start) is active, indicated by 'h'.

    Figure 7: Display showing 'h' for OPA delay.

  • Incorrect Temperature Readings: Check the sensor connection. Ensure the sensor is properly installed and not damaged. Consider using the Temperature Correction function (OFE) if a consistent offset is observed.
  • Relay Not Activating: Verify that the power supply is within the specified range (DC 6-30V). Check if the relay enable function is active ('on' via serial control or default enabled). Ensure the temperature conditions meet the set points for heating or refrigeration mode.
  • Module Unresponsive: Try restoring factory settings by pressing 'STOP' and 'SET' simultaneously for more than 3 seconds.

9. User Tips

  • Sensor Wire Length: While the product specifications indicate a 1m cable length, some users have reported receiving wires around 50cm. Please verify the actual length upon receipt and plan your installation accordingly.
  • Temperature Range Clarification: The module is designed for a temperature control range of -50°C to 110°C. Ensure your application's temperature requirements fall within this range for optimal performance.

10. Warranty & Support

For further assistance or detailed technical information, please refer to the official PDF user manual available for download. You can find a link to the PDF manual here: View User Manual (PDF)

Manufacturer & EU Representative Information

  • Manufacturer: Shenzhen Hangyue Trading Co., Ltd
  • Address: No. 8, Qiaoxin South Road 2nd Street, Simapu Town, Chaonan District, Shantou City, Guangdong Province, China
  • E-mail: 3145108347@qq.com
  • EU Authorized Representative: ZHEKAN GmbH
  • Address: Romeracker 8, 76297 Stutensee, Germany
  • E-mail: eken190228@gmail.com

Compliance Information: This product is CE certified.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.