1. Caution
- KEEP CHILDREN AWAY.
- TO REDUCE THE RISK OF ELECTRIC SHOCK, USE ONLY INDOORS.
- RISK OF ELECTRIC SHOCK. DO NOT PLUG INTO ANOTHER RELOCATABLE POWER TAPS OR AN EXTENSION CORD.
- USE ONLY IN DRY LOCATION.
2. Product Features
The INKBIRD Temperature Controller series offers precise temperature management for various applications. Key features include:
- Plug and Play: Easy to set up and use.
- Dual Relay Control: One relay for output control (heating/cooling), another for abnormal protection.
- Temperature Units: Supports both Celsius (°C) and Fahrenheit (°F) readings.
- Dual Display: Simultaneous display of measured temperature (PV) and target temperature (SV).
- Temperature Calibration: Allows for fine-tuning temperature readings.
- Alarms: High and low temperature alarms, probe abnormal alarm, clock abnormal alarm, and time reset alarm.
- Compressor Delay Protection: Ensures safe operation of cooling equipment.
- Permanent Settings: Saves your settings even after power loss.
- WiFi Connectivity (ITC-308WIFI): Smart control via iOS and Android app (InkbirdSmart) using a 2.4GHz Wi-Fi router.
Applications:

The INKBIRD temperature controllers are suitable for a wide range of uses, from greenhouses and brewing to aquariums and pet incubation.
Model Differences:

This table highlights the differences in features across the ITC-310T, ITC-308, and ITC-306T models.
Probe Differences:

Comparison of standard NTC probe and 30cm NTC probe. The 308S series probes are replaceable, unlike the standard 308 model.
3. Control Panel
The control panel features a dual display for current and target temperatures, along with intuitive buttons for settings and adjustments.

Front and back view of the temperature controller, illustrating the display, buttons, and various socket types.
- PV (Process Value): Displays the current measured temperature in normal mode, or menu code in setting mode.
- SV (Set Value): Displays the target temperature (at which heating/cooling stops) in normal mode, or menu setting in setting mode.
- Red Indicator: Illuminates when heating output is ON, turns OFF when heating output is OFF.
- SET Key: Used to enter parameter setting mode and scroll through menu options.
- UP/DOWN Keys: Used to increase or decrease setting values.
- Output Sockets: Both sockets are typically for heating (for ITC-306T-WIFI model, refer to specific model instructions for cooling output).
4. Setup: INKBIRD App Setting (for WiFi models)
4.1 Download the App
Search for "INKBIRD" in your device's App Store (iOS) or Google Play Store (Android), or scan the QR code below to download and install the "InkbirdSmart" app.

Scan this QR code to download the InkbirdSmart app.
4.2 Pair with Your Phone
- Open the InkbirdSmart app. You will be prompted to register or log in. Select your country and enter your email to complete registration. Then, press "Add Home" to create your home environment in the app.
- Tap the "+" or "Add Device" button on the app's home page.
- If the controller is in normal working state, long press the SET button for 2 seconds to reset the Wi-Fi. The device will enter Smartconfig mode by default. You can short press SET to switch between Smartconfig and AP mode. Allow about 5 seconds for the LED symbol to display the Wi-Fi state.
Video Guide for WiFi Setup:
This video demonstrates the process of connecting your INKBIRD temperature controller to the WiFi network via the app.
Add Device in Quick Connection (Smartconfig):
- Plug the device into a power socket. Ensure the device is in Smartconfig mode (LED symbol flashing rapidly, 250ms interval).
- In the app, click "Confirm indicator rapidly blink", then select your Wi-Fi network, enter the password, and click "Confirm" to start the connection.
Add Device in AP Mode:
- Plug the device into a power socket. Ensure the device is in AP Configuration State (LED symbol flashing slowly, 1500ms interval).
- In the app, click "Confirm indicator slowly blink", then select your Wi-Fi network, enter the password, and click "Confirm" to start the connection.
- Press "Connect now" to go to your phone's WLAN settings. Select the "SmartLife-XXXX" network to connect directly without a password.
- Return to the app to enter the automatic connection interface.
Note: The device only supports 2.4GHz Wi-Fi routers.

App registration screen.

App 'Add Device' screen.
Once the device is successfully added, click "Done" to enter the device controlling interface. In temperature control mode, you can set control functions via the app.
5. Operation: Function Instruction
5.1 Button Instruction
Factory Reset
Hold the DOWN button while powering on the device. The buzzer will beep once, and all parameters will restore to factory settings.
Button Instruction in Setting Mode
When the controller is working normally, press the SET key for 2 seconds to enter parameter setting mode. The PV window displays the menu code (e.g., "TS1"), while the SV window displays the setting value. Press the SET button to scroll down through the menu options and save the current parameter. Use the UP or DOWN buttons to change the current setting value.
If there is no button operation within 30 seconds, or if you long press the SET button for 2 seconds in the setting state, the device will exit the setting mode, save all changes, and return to normal working mode.
5.2 Menu Setting Flow Chart

This flow chart details the navigation and settings within the controller's menu.
5.3 Setup Menu Instruction
| Menu Code | Display Symbol | Menu Function | Setting Range | Default Setting | Remarks |
|---|---|---|---|---|---|
| TS1 | tS1 | Temperature Set Value 1 | -50.0°C~99.0°C -58.0°F~210°F | 25.0°C 77.0°F | 6.4.1 |
| DS1 | dS1 | Heating Differential Value 1 | 0.3°C~15.0°C 1.0°F~30.0°F | 1.0°C 2.0°F | |
| AH | AH | High Temperature Alarm | -50.0°C~99.0°C -58.0°F~210°F | 99.0°C 210°F | 6.5 |
| AL | AL | Low Temperature Alarm | -50.0°C~99.0°C -58.0°F~210°F | -50.0°C -58.0°F | 6.5 |
| CA | CA | Temperature Calibration | -15.0°C~15.0°C -15.0°F~15.0°F | 0.0°C 0.0°F | 6.6 |
| CF | CF | Fahrenheit or Celsius Setting | C/F | F | 6.7 |
| ALM | ALM | Buzzer Sound | ON/OFF | ON | 6.8 |
| TR | tr | Timer Mode Setting | 0: Normal Mode 1: Timer Mode | 0: Normal Mode | 6.4.2 |
Detailed menu settings and their functions.
5.4 Control Function Instruction
Temperature Control in Normal Mode (TR=0)
When the controller is in normal working mode (TR=0), the PV window displays the measured temperature, and the SV window displays the temperature set value.
- If the measured temperature (PV) is greater than or equal to the Temperature Set Value 1 (TS1), the WORK indicator turns OFF, and the output sockets turn OFF.
- If the measured temperature (PV) is less than or equal to (TS1 - Heating Differential Value 1 (DS1)), the WORK indicator turns ON, and the output sockets turn ON.
Example: If TS1 = 25.0°C and DS1 = 3.0°C, the output sockets turn ON when the measured temperature is ≤ 22°C (TS1-DS1), and turn OFF when the measured temperature is ≥ 25°C (TS1).
Temperature Control in Timer Mode (TR=1)
When Timer Mode (TR=1) is enabled, the controller operates on a 24-hour cycle (Time A ~ Time B ~ Time A). Parameters TS2, DS2, TAH, TAM, TBH, TBM, CTH, CTM are used in this mode.
- During Time A ~ Time B: The controller uses Temperature Set Value 1 (TS1) and Heating Differential Value 1 (DS1).
- During Time B ~ Time A: The controller uses Temperature Set Value 2 (TS2) and Heating Differential Value 2 (DS2).
Example: Set TS1=25, DS1=2, TR=1, TS2=18, DS2=2, TAH=8, TAM=30, TBH=18, TBM=00, CTH=9, CTM=30. Current time setting is 9:30.
- During 8:30-18:00 (Time A~Time B): Temperature controls between 22°C (TS1-DS1) and 25°C (TS1).
- During 18:00-8:30 (Time B~Time A): Temperature controls between 16°C (TS2-DS2) and 18°C (TS2).
6. Alarms
High/Low Temperature Alarm (AH, AL)
- High Temperature Alarm (AH): When the measured temperature exceeds the High Temperature Alarm (AH) setting, the device will alarm and turn off heating output. The PV window will alternately display "AH" and the measured temperature at 1Hz frequency. If ALM=ON, the buzzer will sound "Bi-Bi-Biii". The alarm will persist until the measured temperature falls below AH, or any button is pressed to silence the buzzer.
- Low Temperature Alarm (AL): When the measured temperature falls below the Low Temperature Alarm (AL) setting, the device will alarm. The PV window will alternately display "AL" and the measured temperature at 1Hz frequency. If ALM=ON, the buzzer will sound "Bi-Bi-Biii". The alarm will persist until the measured temperature rises above AL, or any button is pressed to silence the buzzer.
Note:
- The Low Temperature Alarm (AL) value should always be less than the High Temperature Alarm (AH) value.
- High or low temperature alarms will be pushed to the mobile app (for WiFi models) to notify the user.
7. Maintenance
7.1 Temperature Calibration (CA)
If there is a deviation between the measured temperature and the actual temperature, use the temperature calibration function. The calibrated temperature will be the measured value plus the calibration value, making it consistent with a standard reference.
7.2 Display in Fahrenheit or Celsius Unit (C/F)
You can set the display unit to either Fahrenheit (°F) or Celsius (°C). The default unit is Fahrenheit. To display in Celsius, set the CF value to 'C'.
Note:
- When the CF setting is changed, all other settings will be restored to their default values, and the buzzer will beep once.
7.3 Buzzer Sound ON/OFF (ALM)
Users can choose to enable or disable the buzzer sound for abnormal alarms. When set to ON, the buzzer will sound during an alarm. When set to OFF, the buzzer will remain silent during an alarm.
8. Troubleshooting
8.1 Error Situations
- Probe Error: The PV window will show "Er" if the probe is not plugged in correctly or if there is a short circuit. If ALM=ON, the buzzer will beep. Press any button to silence.
- Time Error: The PV window will show "Err" if there is a time abnormality. If ALM=ON, the buzzer will beep. Press any button to silence.
- Time Reset Error: If TR=1 and the device powers on after a power off, the PV window will alternately display the current temperature and "TE" at 1Hz frequency. If ALM=ON, the buzzer will sound every two seconds, indicating the timer needs resetting. Press any button to stop the alarm. Long press for 2 seconds to enter the setting menu, skip to CTH menu code, set CTH and CTM values, save parameters, and the device will return to normal operation. Alternatively, normal operation can be restored by tapping the synchronization time via the app.
8.2 Common App Problems
| Status | Possible Cause | Preliminary Solution |
|---|---|---|
| Login Failure | Incorrect account and password | Re-type password and confirm |
| Network server under maintenance | Try again later | |
| Connection Failure | Misoperation (Ignore important steps) | Confirm the correct steps and try again |
| Incorrect WiFi password | Plain-text input password | |
| Poor network condition | Try again or change network environment | |
| Phone model & system version | Switch to another phone and try again | |
| Data Load Failure | Network server under maintenance | Try again later |
| APP Black Screen | Running app takes up too much memory | Clear the running APP |
| Incomplete installation | Uninstall INKBIRD App and re-install |
Solutions for common issues encountered with the InkbirdSmart app.
9. Specifications
| Parameter | Value |
|---|---|
| Power | 100~240Vac 50/60Hz 10A MAX |
| Temperature Probe Type | R25°C=10KΩ±1%, R0°C=26.74~27.83KΩ B25/85°C=3435K±1% |
| Temperature Control Range | -50.0°C~99.0°C / -58.0°F~210°F |
| Temperature Measurement Range | -50.0°C~120°C / -58.0°F~248°F |
| Temperature Display Accuracy | 0.1°C/°F (<100°C/°F), 1°C/°F (≥100°C/°F) |
| Display Unit | Celsius °C or Fahrenheit °F |
| Ambient Temperature | -20°C~40°C / -4.0°F~104°F |
| Storage Temperature | 0°C~60°C / 32°F~140°F |
| Storage Humidity | 20~80%RH (unfrozen or condensation state) |
| Output Control Load | Max. 10A, 100V~240V AC (2200W for 220-240V) |
| Input Power Cable Length | 1.5m (5ft) |
| Output Power Cable Length | 30cm (1ft) |
| Sensor Type | NTC sensor (included) |
| Sensor Length | 2m / 6.56ft |
| Relay Capacity | Cooling / Heating (10A, 100-240V AC) (ITC-306 only heating) |
| Max. Time Periods | ITC-310T-B: 12 periods, ITC-308 and 308S: 6 periods |
| Body Size | 140x68x33mm (5.5x2.7x1.3 inches) |
Detailed technical specifications for the INKBIRD temperature controller series.
Temperature Measurement Accuracy
| Range of Temperature (T) Celsius | Celsius Error | Range of Temperature (T) Fahrenheit | Fahrenheit Error |
|---|---|---|---|
| -50°C ≤ T < 10°C | ±2°C | -58°F ≤ T < 50°F | ±3°F |
| 10°C ≤ T ≤ 100°C | ±1°C | 50°F ≤ T ≤ 212°F | ±2°F |
| 100°C < T ≤ 120°C | ±2°C | 176°F < T ≤ 248°F | ±3°F |
Accuracy of temperature measurement across different ranges.
10. User Tips
- The app is generally easy to connect and program, making setup straightforward.
- If the controller's cable to the power strip seems short for your setup, consider using a suitable extension cord for optimal placement.
- The temperature probe may not be easily shapeable. For stable placement, you might need a probe holder or a cup to secure it in your desired environment.
- The controller works effectively with aquarium coolers, confirming its compatibility for such applications.
11. Warranty and Support
11.1 Technical Assistance
If you encounter any problems during the installation or use of this controller, please thoroughly review this instruction manual. For further assistance, you can contact us at support@inkbird.com. We aim to reply to emails within 24 hours from Monday through Saturday. You can also visit our website at www.inkbird.com for common technical questions and resources.
11.2 Warranty
INKBIRD TECH. C.L. warrants this controller for two years (temperature probe for one year) from the date of purchase, provided it is operated under normal conditions by the original purchaser (non-transferable). This warranty covers defects caused by INKBIRD's workmanship or materials. The warranty is limited to repair or replacement, at INKBIRD's discretion, of all or part of the controller. The original purchase receipt is required for all warranty claims.
12. FCC Requirement
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
Note:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
13. Contact Information
INKBIRD TECH.C.L
Email: support@inkbird.com
Factory Address: 6th Floor, Building 713, Pengji Liantang Industrial Area, NO.2 Pengxing Road, Luohu District, Shenzhen, China
Office Address: Room 1803, Guowei Building, NO.68 Guowei Road, Xianhu Community, Liantang, Luohu District, Shenzhen, China
Certifications: FC CE ROHS