SINOTIMER SVP716-110V

Contents

SINOTIMER SVP716-110V Adjustable Over/Under Voltage and Over Current Protector User Manual

Model: SVP716-110V | Brand: SINOTIMER

1. Introduction

The SINOTIMER SVP716-110V is an intelligent single-phase protective device designed to safeguard electrical equipment from overvoltage, undervoltage, and overcurrent conditions. It features dual LED displays for real-time voltage and current monitoring and offers adjustable protection parameters. When an abnormal voltage or current state is detected, the device instantly cuts off the power supply to prevent damage. It automatically restores power once the line voltage and current return to normal, ensuring continuous protection for your appliances.

2. Safety Information

WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel.

  • Always disconnect power before installation or servicing the device.
  • Ensure proper wiring according to the provided diagrams and local electrical codes.
  • Do not operate the device if it appears damaged.
  • Keep the device away from moisture and extreme temperatures.

3. Product Overview

The SVP716-110V features a compact design for DIN rail mounting and an intuitive interface for easy operation.

3.1. Components

Front view of SINOTIMER SVP716-110V with dual LED display and control buttons
Figure 1: Front Panel with Dual LED Displays and Control Buttons
Angled view of the protector showing IN/OUT terminals and connected wires
Figure 2: Angled view showing IN/OUT terminals

Front Panel:

  • Upper LED Display: Shows real-time voltage (Voltmeter).
  • Lower LED Display: Shows real-time current (Ampmeter).
  • Indicator Lights:
    • >V V: Overvoltage indicator
    • <V V: Undervoltage indicator
    • >A A: Overcurrent indicator
    • POWER: Power status indicator
  • Control Buttons:
    • SET: Enter/Exit setting mode, save settings.
    • UP (Triangle Up): Increase value, navigate settings.
    • DOWN (Triangle Down): Decrease value, navigate settings.
    • ON/OFF (Power Symbol): Manually turn power output ON/OFF.

Terminals:

  • IN (N, L): Input terminals for Neutral and Live wires.
  • OUT (N, L): Output terminals for Neutral and Live wires to the load.

4. Specifications

Parameter Value
Model NumberSVP716-110V
TypeMini Circuit Breaker, Adjustable Voltage & Current Protector (VA Type ADJ)
Pole No.1P+N
Rated Voltage100/120V AC, 50/60Hz
Rated Current (Max Load)40A, 63A, 80A (Default: 40A/63A/80A)
Over-voltage Protection Range130-150V (Default: 140V)
Under-voltage Protection Range70-105V (Default: 80V)
Over-current Protection Range1-40A, 1-63A, 1-80A (Default: 40A/63A/80A)
Protection Setting Time0.1-30S (Default: 1S)
Recovery Delay Time1-600S (Default: 5S)
Continuous Over-current Protection TimesAdjustable (Default: 10)
Power Consumption<2W
Electro-mechanical Life100,000 times
Installation35mm symmetrical DIN rail
CertificationsCE, RoHS, EMC, LVD
Dimensions36*65*85mm

5. Setup

5.1. Installation

The SVP716-110V is designed for DIN rail mounting. Ensure the DIN rail is securely installed in a suitable electrical enclosure.

  1. Mount the device onto a standard 35mm DIN rail by clipping it into place.
  2. Ensure adequate ventilation around the device.

5.2. Wiring Diagram

Connect the device according to the following wiring diagram. Ensure all connections are tight and secure.

Wiring diagram for 120VAC version showing N and L input and output terminals
Figure 3: Wiring Diagram (120VAC Version)
  • IN (N): Connect the Neutral wire from the power source to the 'N' input terminal.
  • IN (L): Connect the Live wire from the power source to the 'L' input terminal.
  • OUT (N): Connect the Neutral wire to your load from the 'N' output terminal.
  • OUT (L): Connect the Live wire to your load from the 'L' output terminal.

Important: Always verify correct polarity (Neutral and Live) to ensure proper device function and safety.

6. Operating Instructions

6.1. Initial Power On

Once wired correctly, apply power to the device. The dual LED displays will light up, showing the current voltage and current values. The 'POWER' indicator will be lit.

6.2. Setting Protection Parameters

The SVP716-110V allows you to customize various protection thresholds and timings. The settings are retained even after power disconnection.

  1. Enter Setting Mode: Press and hold the SET button for approximately 5 seconds until the display starts flashing, indicating you are in setting mode.
  2. Navigate Settings: Press the SET button briefly to cycle through the different adjustable parameters (Over-voltage, Under-voltage, Over-current, Protection setting time, Recovery delay time, Continuous over-current protection times).
  3. Adjust Values: Use the UP (Triangle Up) and DOWN (Triangle Down) buttons to change the value of the currently selected parameter. Long-press these buttons for faster adjustment.
  4. Save Settings: After adjusting all desired parameters, press and hold the SET button for approximately 5 seconds to save the changes and exit the setting mode. The display will stop flashing.
  5. Restore Factory Defaults: To reset all settings to their factory default values, press and hold the SET, UP, and DOWN buttons simultaneously for 5 seconds.

Adjustable Parameters (120VAC Version Defaults):

  • Over-voltage Protection (OV): 130-150V (Default: 140V)
  • Under-voltage Protection (UV): 70-105V (Default: 80V)
  • Over-current Protection (OC): 1-40A, 1-63A, 1-80A (Default: 40A/63A/80A, depending on model variant)
  • Protection Setting Time: 0.1-30 seconds (Default: 1 second) - Time before protection trips.
  • Recovery Delay Time: 1-600 seconds (Default: 5 seconds) - Time before power is restored after a protection event.
  • Continuous Over-current Protection Times: Adjustable (Default: 10) - Number of times overcurrent can occur before a longer lockout.

6.3. Manual ON/OFF

You can manually turn the power output ON or OFF using the power button:

  • Turn OFF: Long press the ON/OFF (Power Symbol) button to cut the power output to the load. The display will show 'OFF'.
  • Turn ON: Long press the ON/OFF (Power Symbol) button again to restore power output.

6.4. Demonstration Video

Watch this video for a visual guide on setting parameters and observing protection functions:

Video: Demonstration of setting adjustable ranges and protection features (Over-voltage, Under-voltage, Over-current, Recovery Delay, Manual ON/OFF).

7. Maintenance

  • Cleaning: Periodically clean the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Inspection: Regularly inspect the wiring connections for any signs of loosening or damage.
  • Environment: Ensure the operating environment is free from excessive dust, moisture, and corrosive gases.

8. Troubleshooting

Problem Possible Cause Solution
Device does not power on. No power supply; incorrect wiring. Check power source. Verify wiring connections (N and L inputs).
Power output is OFF, but voltage/current is normal. Device is in manual OFF state; protection triggered and not yet recovered. Long press the ON/OFF button to manually turn it ON. Check if recovery delay time is still counting down.
Device frequently trips. Protection parameters set too sensitive; unstable power supply; load issues. Adjust protection thresholds (OV, UV, OC) to appropriate levels. Check power quality. Inspect connected load for faults.
Settings are not saved. Did not exit setting mode correctly. Ensure you long-press the SET button for 5 seconds to save and exit after making changes.
Display shows 'OFF' or 'Err'. Manual OFF; internal error. If 'OFF', long press ON/OFF button to restore. If 'Err', try resetting to factory defaults or contact support.

9. User Tips

  • Generator Protection: This device is highly effective for protecting sensitive equipment connected to generators, especially against voltage drops. Adjust the undervoltage protection and recovery delay time to suit your generator's characteristics and load requirements.
  • Settings Retention: The device retains its programmed settings even after power is disconnected, eliminating the need for re-configuration after outages.
  • Adjustable Parameters: Take advantage of the adjustable voltage and amperage settings to precisely match the protection needs of your specific devices.
  • Micro Power Outages: The fast protection setting time (as low as 0.1 seconds) can help mitigate issues caused by micro power outages or rapid voltage fluctuations.

10. Warranty and Support

For detailed warranty information and technical support, please refer to the official product documentation or contact SINOTIMER customer service.

A comprehensive user manual in PDF format is available for download: View User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.