Gaqqee EM4020-DC

Contents

Gaqqee DC 6-200V Digital Voltmeter Ammeter User Manual

Model: EM4020-DC

1. Introduction

The Gaqqee EM4020-DC Digital Voltmeter Ammeter is a multifunctional DC meter designed for real-time display and monitoring of voltage, current, power, and electricity consumption. It features a high-quality flame-retardant ABS material construction with a buckle design for stable installation. The LED screen provides 360-degree viewing with explosion-proof protection and backlight for clear data display even in dim environments. This device is suitable for a wide range of applications, including power distribution cabinets, exhibition racks, photovoltaic inverters, assembly line testing, and electronic maintenance.

Gaqqee DC Voltmeter Ammeter with Shunt

Figure 1: Gaqqee DC Voltmeter Ammeter and Shunt

2. Package Contents

Please check the package for the following items:

  • Digital Voltmeter Ammeter (Multimeter) x 1
  • Diverter (Shunt) x 1 (Specific current rating, e.g., 20A, 50A, or 100A, depending on model purchased)

3. Setup and Installation

3.1 Physical Installation

The meter is designed with an all-round buckle for stable and secure clamping. Ensure the installation location is dry, well-ventilated, and within the specified environmental conditions.

3.2 Wiring Instructions

Proper wiring is crucial for accurate measurement and safe operation. Refer to the diagrams below and the detailed instructions in the full user manual (PDF) for specific applications.

Back of Gaqqee EM4020-DC Meter with Wiring Diagram

Figure 2: Basic Wiring Diagram for EM4020-DC Meter (Max 20A shown)

  • Terminals 1 & 2 (Power Input): Connect to the DC 6-200V power source for the meter's operation.
  • Terminals 3 & 4 (Load): Connect to the load or circuit being measured.
  • Shunt Connection: The diverter (shunt) must be connected in series with the load to measure current. Ensure the correct shunt (20A, 50A, or 100A) is used for your application.

3.3 External Alarm Wiring

The meter can be connected to an external alarm or PLC to trigger signals when set values are exceeded.

External Siren Wiring Diagram

Figure 3: External Siren Wiring Diagram

External Alarm and PLC Setup

Figure 4: External Alarm and PLC Integration

When the set alarm value is exceeded, the meter's display will flash, and the buzzer will prompt (if enabled). Overvoltage, undervoltage, and overload signals can be output to drive external devices like alarms or PLCs.

3.4 Solar Panel and Battery Wiring (Reference)

For detailed wiring diagrams involving solar panels and batteries, please refer to the comprehensive PDF user manual. These diagrams typically illustrate:

  • Measuring Solar Panel Output: How to connect the meter to measure the output voltage, current, and power of a solar panel. Note that the solar panel may not output automatically when shut down.
  • Measuring Battery Parameters: How to connect the meter to measure battery voltage, charging/discharging current, and power. Discharging power is shown as positive, while charging power is shown as negative.
  • Specific wiring for 20A, 50A, and 100A DC tables, indicating connections for red and green lines.

4. Operating Instructions

4.1 Display Overview

The meter provides a clear LED display showing four key parameters simultaneously:

Gaqqee Meter Displaying Measurements

Figure 5: Meter Displaying Voltage, Current, Power, and Energy

  • Voltage (V): Displays the measured DC voltage.
  • Current (A): Displays the measured DC current.
  • Power (kW/W): Displays the calculated power.
  • Energy (kWh/Wh): Displays the accumulated energy consumption.

4.2 Measurement Ranges and Resolution

Parameter Range Resolution
Voltage <100V: 6.00~99.99 V
≥100V: 100.0~200.0 V
0.01V
Current <10A: 0.000~9.999 A
≥10A: 10.00~99.99 A
0.001A
Power <1kW: 0.0~999.9 W
≥1kW: 1.00~99.99 kW
Electricity <10kWh: 0~9999 Wh
≥10kWh: 10.00~9999 kWh

4.3 Alarm Function

The meter supports setting overvoltage, undervoltage, and overload alarm values. When a measured value exceeds the set threshold, the corresponding display value will flash, the screen will flash, and an internal buzzer will sound (if enabled). This can also trigger external alarms as described in Section 3.3.

4.4 Reverse Power Measurement

This meter is capable of measuring reverse current and reverse power. These values will be displayed as negative numbers on the screen, indicating power flow in the opposite direction (e.g., during battery charging).

4.5 SET Button Functionality

The 'SET' button on the meter is used for various functions, including:

  • Accessing and adjusting alarm thresholds.
  • Resetting accumulated energy data (kWh/Wh).
  • Cycling through display modes or settings.

Refer to the detailed PDF manual for specific sequences and options related to the 'SET' button.

5. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the meter's display and casing. Do not use abrasive cleaners or solvents.
  • Environmental Conditions: Operate and store the meter within the specified environmental conditions (0-40°C, <80% RH) to ensure longevity and accuracy. Avoid exposure to extreme temperatures, humidity, or direct sunlight.
  • Inspection: Periodically check wiring connections for tightness and signs of wear or damage.

6. Troubleshooting

  • No Display / Dim Display: Ensure the meter is receiving power within the DC 6-200V range. Check wiring connections. The backlight should ensure clear display in dim environments.
  • Incorrect Readings: Verify that the correct shunt is installed for the measured current range. Double-check all wiring connections for proper polarity and secure contact.
  • Alarm Constantly Triggering: Review your set alarm thresholds (overvoltage, undervoltage, overload) to ensure they are appropriate for your application.
  • Resetting Data: If you need to clear accumulated energy data, use the 'SET' button as described in the full manual. The meter also features power failure data storage, so data should persist across power cycles unless manually reset.

7. Specifications

Feature Specification
Model Number EM4020-DC
Input Voltage DC 6-200V
Current Range 20A, 50A, 100A (requires corresponding shunt)
Power Consumption <1W
Operating Temperature 0~40℃
Operating Humidity <80% RH
Dimensions (Meter) 110 x 59 x 30 mm (approx. 4.33 x 2.32 x 1.18 inches)
Display Type Analog and Digital LED
Certification CE
DIY Supplies Electrical
Battery Included No
Gaqqee Meter and Shunt with Dimensions

Figure 6: Meter and Shunt with Approximate Dimensions

8. User Tips

  • Shunt Selection: Always ensure you are using the correct current shunt (e.g., 20A, 50A, 100A) that matches your measurement requirements and the meter's configuration. Using an incorrect shunt will result in inaccurate current readings.
  • Wiring Verification: Before applying power, meticulously double-check all wiring connections for correct polarity and secure fastening to prevent damage to the meter or the circuit.
  • Alarm Utilization: Make full use of the overvoltage, undervoltage, and overload alarm functions, especially in critical applications, to protect your equipment and ensure safe operation.
  • Data Storage: The meter retains data even after power loss, which is useful for long-term monitoring. Remember to manually reset the energy (kWh/Wh) if you need to start a new measurement cycle.

9. Warranty and Support

For detailed warranty information, advanced troubleshooting, or specific technical support, please refer to the official user manual PDF provided by the manufacturer. You can access the PDF manual at: Gaqqee EM4020-DC User Manual (PDF).

If you require further assistance, please contact the seller or manufacturer directly with your product model and any relevant details.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.