1. Introduction
The MESR-100 ESR Capacitor Tester is a professional, auto-ranging ESR (Equivalent Series Resistance) and Low Ohm Meter designed for measuring capacitance and internal resistance. It supports in-circuit testing, making it a valuable tool for electronics enthusiasts and professionals.
This device utilizes a true 100 KHz sine wave to measure the ESR value, aligning with the testing methods used by capacitor manufacturers. Unlike some techniques that use short pulse methods, which can yield varying values depending on capacitance, the MESR-100 provides consistent and reliable readings.
2. What is ESR?
ESR (Equivalent Series Resistance) refers to the series resistor inside a capacitor. By using a 100kHz test frequency, the impedance 1/(2*pi*F*C) becomes very small, allowing the meter to accurately measure the true series resistance value. A higher ESR value typically indicates a bad or aged electrolytic capacitor, which can lead to increased ripple and reduced filtering effectiveness. Generally, a large capacitor with an ESR greater than 3 ohms is considered faulty.
The MESR-100 applies less than 15mV DC or peak-to-peak voltage to a good capacitor, enabling safe and effective in-circuit testing. This low testing voltage prevents the activation of semiconductors within the circuit under test, making it ideal for diagnosing components on TV, LCD, and audio boards without desoldering.
3. Key Features and Improvements (V2)
The MESR-100 V2 model incorporates several enhancements over previous versions:
- Improved Test Waveform: Switched from square wave to 100 KHz sine wave, reducing high-frequency components that could affect readings through test leads and capacitors.
- High Resolution: Offers a resolution of up to 0.001 ohm.
- Enhanced Display: Features a 128x64 dot matrix LCD, providing larger value display and more comprehensive information.
- Integrated ESR Table: Includes an embedded 25V capacitor ESR reference table on the LCD, automatically indicating if a capacitor is good or bad based on common 25V electrolytic capacitor standards.
- Ergonomic Design: New plastic case with a curved design for comfortable hand-carrying.
- Convenient Stand: A new stand allows the meter to be positioned at a 60-degree angle on a desk for easy viewing.
- Battery Life: Uses 2x AA 1.5V batteries, offering greater convenience and longer battery life compared to 9V batteries.
- External Power Support: Supports external 5V power via a standard micro-USB port.
4. Safety Information
WARNING: Always discharge capacitors before testing!
Before testing any capacitor, it is crucial to discharge it completely. You can do this by short-circuiting the capacitor terminals with a screwdriver or by connecting a 10-ohm resistor in series and shorting for 5 to 10 seconds. Although the meter has two fast diodes to prevent high voltage damage, a large surge current and voltage from an undischarged capacitor can still damage the meter.
California's Proposition 65 Warning: This product contains Acetochlor, a chemical known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.
5. Setup
5.1. Powering On/Off
- To power on, press and hold the ON/OFF (orange circle) button for 2 to 3 seconds.
- To shut down, press and release the ON/OFF button.
5.2. Power Supply
- The meter operates on 2x AA 1.5V batteries.
- For external power, connect a standard micro-USB cable to the micro-USB port. This allows the meter to operate without batteries.
5.3. Using the Stand
The meter includes a plastic stand for convenient desktop use, allowing it to stand at a 60-degree angle. If not in use, press and push the stand into its locked position to secure it.
5.4. Zero Calibration (1 Key Zero)
To ensure accurate measurements, perform a zero calibration:
- Short circuit the terminals of the test leads (connect the red and black clips together).
- Press and release the "ZERO" button. The LCD will display "ZERO" and then disappear, indicating successful calibration.
- If using the meter array socket, use a short pin to short circuit the socket before pressing "ZERO".
6. Operating Instructions
6.1. Auto/Manual Mode Selection
- Auto Range: Press and release the "MODE RANGE" button. The LCD will show "AUTO:". In this mode, the meter automatically selects the best range for detection.
- Manual Range: Press and release the "MODE RANGE" button repeatedly to cycle through manual ranges: 0-1R, 1-10R, and 10-100R. The LCD will display "MANUAL" and the selected range.
6.2. Testing Capacitors
After performing zero calibration, connect the test leads to the capacitor you wish to test. The ESR value will be displayed on the LCD. The MESR-100 supports both out-of-circuit and in-circuit testing.
6.3. ESR Reference Table
The meter features an embedded ESR reference table for 25V electrolytic capacitors. This table provides typical ESR values for various capacitance ratings and voltages, allowing you to compare your measured ESR value to determine if a capacitor is aged or damaged. Remember that ESR values can vary between manufacturers, so it's best to compare with a known good capacitor of the same type if possible.
| Capacitance | 10V | 16V | 25V | 35V | 63V | 100V | 250V |
|---|---|---|---|---|---|---|---|
| 1uF | 14 | 16 | 18 | 20 | |||
| 2.2uF | 6.0 | 8.0 | 10 | 10 | 18 | ||
| 4.7uF | 15 | 7.5 | 4.2 | 2.3 | 5.0 | ||
| 10uF | 8.0 | 5.3 | 3.2 | 2.4 | 3.0 | 2.5 | |
| 22uF | 5.4 | 3.6 | 2.1 | 1.5 | 1.5 | 1.5 | 1.8 |
| 47uF | 2.2 | 1.6 | 1.2 | 0.68 | 0.56 | 0.7 | 0.8 |
| 100uF | 1.2 | 0.7 | 0.32 | 0.32 | 0.3 | 0.15 | 0.8 |
| 220uF | 0.6 | 0.33 | 0.23 | 0.17 | 0.16 | 0.09 | 0.5 |
| 470uF | 0.24 | 0.18 | 0.12 | 0.09 | 0.09 | 0.05 | 0.3 |
| 1000uF | 0.12 | 0.09 | 0.08 | 0.07 | 0.05 | 0.06 | |
| 4700uF | 0.23 | 0.20 | 0.12 | 0.08 | 0.04 | ||
| 10000uF | 0.12 | 0.08 | 0.06 | 0.04 |
6.4. Backlight
The LCD backlight will automatically turn on when the meter is powered on.
7. Maintenance
7.1. Auto Sleep Function
To conserve battery life, the MESR-100 will automatically shut down after approximately 10 hours of inactivity (no testing performed).
7.2. Cleaning
Keep the device clean and free from dust. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
7.3. Battery Replacement
When the battery indicator on the LCD shows low power, replace the 2x AA 1.5V batteries. The battery cover is located on the back of the device.
8. Troubleshooting
8.1. "OL" or Overflow Display
If the LCD displays "OL" (Overflow), it indicates that the measured value is out of the current range. Ensure that you have performed the zero calibration correctly. If in manual mode, try switching to a higher range or auto mode.
8.2. Inaccurate Readings
Measurement accuracy can be affected by the length of the test leads and the contact point resistance. The standard test leads are 15cm. For longer test leads, special shielding may be required to mitigate EMI (Electromagnetic Interference). If you suspect inaccuracies, ensure good contact with the component and re-perform zero calibration.
8.3. Device Damage
Failure to discharge capacitors before testing can lead to a large surge current and voltage, potentially damaging the meter. Always follow the safety guidelines in Section 4.
9. Specifications
| Parameter | Value |
|---|---|
| Model Number | MESR-100 |
| Display Type | Digital Only |
| DIY Supplies | Electrical |
| Measuring Range | >1uF |
| Accuracy Class | Up to 1% |
| Dimensions | 14.5 * 8 * 3cm / 5.7 * 3.1 * 1.2in |
| Battery Included | No (Requires 2x AA 1.5V batteries) |
| External Power | 5V micro USB |
| Operating Current | 0.02A |
| Battery Life | >80 Hours |
| Clamping Voltage | ~0.15V (open voltage) |
| Measuring Voltage | <~40mV RMS (TESTING VOLTAGE) |
| High Resolution | 4 digit, or 0.001Ohm @ 1 Ohm range |
| Refresh Time | ~0.4s (Manual Mode) |
| Certification | CE |
10. User Tips
- The MESR-100 is generally reported to work great for its intended purpose.
- The product typically includes both alligator clips (for larger components) and SMD clips (for surface-mount devices), providing versatility for various testing needs.
11. Warranty and Support
For detailed information regarding warranty, returns, or technical support, please refer to the official user manual PDF or contact the seller directly.
Official User Manual (PDF): A comprehensive user guide is available for download. View User Manual (PDF)