SNDWAY SW-B40, SW-B50, SW-B60

Contents

SNDWAY Laser Distance Meter User Manual

Models: SW-B40, SW-B50, SW-B60

1. Introduction

This manual provides detailed instructions for the safe and effective use of your SNDWAY Laser Distance Meter. Please read this manual thoroughly before operating the device and keep it for future reference. Improper operation without complying with this manual could cause damage to the device, influence measurement results, or cause bodily injury.

The SNDWAY Laser Distance Meter is a precision instrument designed for accurate distance, area, and volume measurements. It features a clear digital display and intuitive controls for various measurement functions.

SNDWAY SW-B40 Laser Distance Meter front view
Figure 1: Front view of the SNDWAY SW-B40 Laser Distance Meter, showing the display and control buttons.

2. Safety Regulations

  • Do not disassemble or repair the instrument in any way.
  • Do not make any illegal modifications or performance changes for the laser emitter.
  • Keep the device out of reach of children.
  • Avoid using the device by any irrelevant personnel.
  • It is strictly prohibited to aim the laser at eyes or other body parts.
  • Do not aim the laser at surfaces with strong reflection.
  • Due to electromagnetic radiation interference, do not use the meter in the plane or around medical equipment.
  • Do not use the device in inflammable or explosive environments.
  • Discarded batteries or the meter device shall not be processed like household garbage; handle them in line with related law and regulations.

3. Product Overview and Package Contents

The SNDWAY Laser Distance Meter comes with the following items:

SNDWAY Laser Distance Meter package contents
Figure 2: Package contents including the laser distance meter, charging cable, manual, bag, and gift box.
Package Contents
No.ItemQtyNote
1Laser distance meter1
2Giftbox1
3User manual1
4USB Type-C cable1

4. Setup and Basic Operation

4.1 Battery Installation and Charging

The product is equipped with a built-in 3.7V/850mAh lithium battery. It is non-removable.

  • Charge the device if it cannot be turned on or if there is no power indication after starting up.
  • Use a charging adapter with DC5V and 1A. The charging port is a microUSB port. (Phone chargers are recommended).
  • During charging, the battery icon will scroll.
  • The battery icon will be displayed and flashing when charging is completed.

4.2 Turning On/Off the Instrument

  • To Turn On: From the off status, press the READ button. The device and laser will start simultaneously and enter standby for measurement.
  • To Turn Off: From the on status, long press the READ button for 3 seconds. The device will also turn off automatically if there is no operation for 150 seconds.
  • Force Shutoff: In case of unexpected errors, long press the READ button for over 10 seconds to force the device to shut off.

4.3 Unit Setting

Long press the UNIT button to reset the current measurement unit. The default unit is 0.000m. There are 6 units available:

  • 0.000 m
  • 0.00 m
  • 0.0 in
  • 0.00 ft
  • 0'00" 1/16
  • 0.00 ft

4.4 Reference Point Setting

Press the REFERENCE button to change the reference point. The device reference point by default is the rear of the device.

5. Operating Instructions

5.1 Turning On/Off Laser

  • To Turn On: When in "to be tested" mode, press the READ button to turn on the laser. The laser icon will appear at the top left of the display.
  • To Turn Off: The laser will turn off automatically in 20 seconds if there is no operation. When the laser is on, just press the READ button to turn it off.

5.2 Backlight On/Off

The backlight is set to turn on and off automatically. It will be on for 15 seconds while operating and will shut off automatically after 15 seconds of no operation.

5.3 Single Distance Measuring

Turn on the laser beam by short pressing the READ button. Under measuring mode, press the READ button again for single measurement of length. The measured result will be displayed in the major display area.

5.4 Continuous Measuring

Long press the READ button under measuring mode to enter continuous measuring mode. The maximum measuring result displays in the auxiliary display area, and the present result displays in the major display area. Short press the READ or CLEAR button to exit continuous measuring mode.

5.5 Area Measurement

Press the AREA/VOLUME button once. The area icon will show on the screen, and one side of the rectangle will be blinking. Follow these steps:

  1. Press READ once for length.
  2. Press READ again for width.

The device calculates and displays the result in the major display area.

5.6 Volume Measurement

Press the AREA/VOLUME button twice to enter volume measurement mode. A 'V' icon will show at the top of the screen. Follow these instructions for volume measuring:

  1. Press READ for Length.
  2. Press READ again for Width.
  3. Press READ a third time for Height.

The device calculates and displays the result in the major display area. Press CLEAR button to clear the result and measure again if necessary.

5.7 Painter Function

When the meter is in Area mode, you can use the add/subtract function to total up the area of several surfaces.

Press the PAINTER button three times until a painter icon is showing in the display.

  1. Press READ to measure the height of the wall first.
  2. Press READ to measure the bottom edge of the first wall. The first area will be displayed in the major display area.
  3. Repeat for additional walls. Press READ to clear the previous measuring result and start a new measurement.

5.8 Pythagoras Measurement

There are four Pythagoras modes for cases where the user finds it hard to reach the target.

Mode 1: Calculate the second leg by measuring the hypotenuse and another leg.

  1. Short press the PYTHAGORAS button four times to enter Pythagoras mode (hypotenuse blinking).
  2. Press READ to measure the length of the hypotenuse (x).
  3. Press READ to measure the length of one leg (b).

The device calculates the length of another leg (x).

Mode 2: Calculate the hypotenuse by measuring the length of two legs.

  1. Short press the PYTHAGORAS button five times (one leg blinking).
  2. Press READ to measure the length of one leg (a).
  3. Press READ to measure the length of another leg (b).

The device calculates the length of the hypotenuse (x).

Mode 3: Three-point Pythagoras (one side blinking).

  1. Press the PYTHAGORAS button six times until one side of the triangle is blinking on the screen.
  2. Press READ to measure the length of one side (a).
  3. Press READ to measure the length of the median line (b).
  4. Press READ to measure the length of another side (c).

The device calculates the length of the leg in full line (x).

Mode 4: Three-point Pythagoras (hypotenuse blinking).

  1. Press the PYTHAGORAS button seven times until the hypotenuse is blinking on the screen.
  2. Press READ to measure the length of one hypotenuse (a).
  3. Press READ to measure the length of another hypotenuse (b).
  4. Press READ to measure the length of one leg (c).

The device calculates the length of the leg in full line (x).

Note: Legs must be shorter than the hypotenuse, or an "err" message will appear on the screen. To guarantee accuracy, ensure all measurements start from the same point.

5.9 Self-Calibration & Sound On/Off Setting

Self-Calibration

The device has a self-calculation function to maintain precision.

  1. Under off status, press the READ and UNIT buttons at the same time until "CAL" shows on the display and a figure twinkles at the bottom.
  2. Adjust the figures using the + and - buttons. The adjusting range is -9 to 9mm.
  3. Press the READ button to save the calibration result.

Sound On/Off Setting

After saving the calibration result, the device enters sound settings mode. A speaker icon will appear on the display, and letters will be flickering at the bottom. Press the UNIT button to control the sound on/off. After settings, press READ or CLEAR to exit the setting.

6. Maintenance

6.1 Battery Maintenance

  • Ensure the device is fully charged if it's not used for a long time.
  • Charge the device every half year to prevent battery damage.

6.2 Instrument Maintenance

  • Do not store the meter in high temperature or strong humidity environments for long periods.
  • If not used often, remove the battery (if removable, though this model has a built-in battery) and place the meter in the allocated portable bag. Store in a cool and dry place.
  • Keep the device surface clean. Use a wet soft cloth to clean dust.
  • Do not use corrosive liquids for cleaning.
  • The laser output window and its focus lens can be maintained according to maintenance procedures for optical devices.

7. Troubleshooting and Error Codes

You may encounter some warning information or error codes as listed below:

Error Codes and Solutions
Error CodeCauseSolution
ErrOut of rangeMeasure within the specified range.
ErrWeak signal / Poor reflectionChoose a surface with stronger reflectance. Use a reflecting plate if necessary.
ErrStrong signal / Too much reflectionChoose a surface with weaker reflectance.
Low powerBattery lowChange the power supply (charge the device).
ErrTemperature out of rangeUse the device within its specified temperature range.

8. Specifications

Technical Specifications
FeatureSpecification
Brand NameSNDWAY
Model NumberSW-B40/SW-B50/SW-B60
Working RangeSW-B40: 40m, SW-B50: 50m, SW-B60: 100m
Measurement Accuracy±2mm
Laser Hazard LevelClass 2 (<1mW)
Laser Type630-670nm, <1mW
Power TypeRechargeable (3.7V 850mAh Lithium Battery)
Battery IncludedYes
Automatic Laser Off20s
Automatic Instrument Off150s
Working Temperature0°C - 40°C
Storage Temperature-20°C - 60°C
Storage Humidity20% - 80% RH
Measurements per ChargeApprox. 18000 times for single measurement
Display4-line segment display
Size105x66.4x38mm
CertificationCE, FCC
High-concerned chemicalNone

Note: A target plate can increase the measurement range during daylight or if the target has poor reflection properties. Typical tolerance is ±2mm under ideal conditions (100% white surface, environment light <2000 LUX, 25°C). Tolerance is affected by distance, reflectivity, and environment light, potentially reaching (2mm + 0.2 mm/m).

9. User Tips

  • Always ensure the device is fully charged before important measurements to avoid interruptions.
  • For best accuracy, especially over longer distances or in bright conditions, use a reflective target plate.
  • Practice with all measurement modes (single, continuous, area, volume, Pythagoras) in a controlled environment to become familiar with their operation before using them for critical tasks.
  • Regularly clean the laser output window and lens with a soft, damp cloth to maintain measurement precision.
  • Remember to check the reference point setting (front or rear of the device) before each measurement, as this significantly impacts accuracy.

10. Frequently Asked Questions (FAQ)

Q: Why is my device not turning on?
A: The battery might be depleted. Please charge the device using the provided USB Type-C cable and a DC5V 1A adapter.
Q: How do I change the measurement unit?
A: Long press the UNIT button to cycle through the available measurement units (m, ft, in, etc.).
Q: What does "Err" mean on the display?
A: "Err" typically indicates a measurement error, such as being out of range, a weak laser signal due to poor reflection, or too strong a signal due to excessive reflection. Refer to the Troubleshooting section for specific solutions.
Q: Can I use the device outdoors in bright sunlight?
A: While the device can be used outdoors, bright sunlight can affect laser visibility and measurement accuracy. Using a reflective target plate is highly recommended in such conditions.

11. Warranty and Support

For any quality issues or questions regarding your SNDWAY Laser Distance Meter, please contact your local distributor or the manufacturer in a timely manner. We are ready to offer solutions for you.

For a complete and detailed user manual, please refer to the official PDF document: SNDWAY Laser Distance Meter User Manual (PDF).

© 2023 SNDWAY. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.