1. Introduction
The ERIKOLE ZFX-9002 Intelligent Incubator Thermostat is a versatile device designed for precise temperature and humidity control in egg incubators. It features automatic egg turning, an integrated egg candler, and is suitable for incubating various types of poultry eggs. This manual provides essential information for safe and effective operation of your thermostat.

Figure 1: ZFX-9002 Thermostat with key features highlighted.
2. Safety & Warnings
Read all instructions before use. Failure to follow these instructions may result in damage to the product or personal injury.
- Warning: Keep the device and its cord out of reach of children under 3 years old.
- Keep away from children unless supervised by an adult.
- Do not use this product for purposes other than its intended use.
- Inspect the product before each use; do not use if damaged.
- Follow installation and operation guidelines to avoid injury.
- Electrical products: Do not expose to water or moisture.
3. Package Contents
Please check the package for the following items:
- 1 x ZFX-9002 Smart Thermostat Unit
- 1 x NTC Temperature Probe
- 1 x Humidity Probe
Note: This product is a wired device; power supply and additional wires are not included and must be sourced separately.
4. Product Overview

Figure 2: Front panel and dimensions (150mm x 88mm).
Front Panel Components:
- Incubation Countdown: Displays time remaining until hatching.
- Real-time Temperature: Shows current temperature inside the incubator.
- Egg Lamp: Integrated LED cold light for candling eggs.
- Incubation Days: Displays the number of days since incubation started.
- Real-time Humidity: Shows current humidity level inside the incubator.
- 12V Power Supply Input: DC 12V power input jack.
- Function Buttons: SET, UP, DOWN, MODE buttons for configuration.
- Humidity Probe: Connects to measure humidity.
- Temperature Probe: Connects to measure temperature.
Probes:

Figure 3: Temperature and Humidity Probes.
- NTC Temperature Probe (0-99.9°C): High precision, waterproof, dustproof, and corrosion-resistant.
- Humidity Probe (0-99%RH): Integrated design, small size, stable performance.
5. Setup
5.1 Wiring Instructions
Ensure all connections are secure before powering on the device. The product does not ship with power supply or wires.
For DC 12V Version:

Figure 4: Wiring Diagram for DC 12V Version.
For AC 220V/110V Version:

Figure 5: Wiring Diagram for AC 220V Version.

Figure 6: Back Panel Wiring for AC 220V/110V Version.
Important Notes for Wiring:
- The sockets on the front of the product always show DC 12V. For 220V/110V products, check the back for the corresponding voltage logo.
- Fans for 12V, 110V, and 220V products can only be connected to a 12V power supply.
- The fan interface can control the fan when connected to a 12V power supply.
- Ensure your power plug size is 5.5*2.1mm, as the product only supports this size.
5.2 Initial Machine Test
- After connecting all circuits, turn on the power.
- Add 50-100mL of water into the smallest compartment of the water tank.
- Test the machine for 2 hours.
- Press the "+" button on the control panel to check if the egg turning mechanism is functioning normally.
- Verify that the temperature displays around 37.8°C and humidity around 60%. If these values are displayed, the machine is operating normally.
- If humidity is less than 60%, add another 50-100mL of water. (If humidity is too high, no adjustment is needed. If it drops below 55%, add a small amount of water.)
6. Operating Instructions
6.1 Basic Operation & Settings
- SET Key:
Factory default settings: Temperature 37.8°C, Humidity 60%RH. (It is not recommended to change these optimal hatching parameters unless you have specific experience.)
Press the SET button to enter setting mode.
To change base temperature: Click "SET", then use "+" or "-" buttons to adjust to the desired temperature. - Work Indicator:
Solid light: Heating tube is active.
Flashing light: Temperature is near the set reference temperature (normal operation). - Display Ranges:
Normal temperature range: 37.3°C - 38.3°C. Alarms if below 37.0°C or above 38.6°C. Ambient temperature should not exceed 30°C and ideally be at least 10°C lower than the set temperature.
Normal humidity range: 50% - 70%. Alarms if below 40% or above 75%. Short-term high/low humidity will not affect hatching, but prolonged deviations should be avoided.
6.2 Automatic Egg Turning
The ZFX-9002 automatically turns eggs to ensure even heating and improve hatching rates.

Figure 7: Automatic Egg Turning Mechanism.
- Egg Turning Cycle Setting: 0-999 minutes (Factory default: 120 minutes).
- Egg Turning Time Setting: 0-999 seconds (Factory default: 15 seconds).
- To observe egg turning: Press the "+" button to manually trigger a flip and observe the egg tray. Factory default is automatic flipping every 90 minutes.
6.3 Egg Candling Function
The integrated LED cold light egg candler allows you to monitor egg development.

Figure 8: Egg Candling in Progress.
Use the egg lamp to clearly see the hatching situation of breeding eggs. This makes it convenient to identify and remove undeveloped, dead, or bad eggs in time.
6.4 Incubation Process
6.4.1 Egg Selection
Select fertilized eggs that are 4-7 days old. Ensure they are clean (no feces), free of cracks, and not contaminated with broken egg liquid. Preheat eggs in a 15-30°C environment for 24 hours before placing them into the incubator after the initial machine test.
6.4.2 Incubation Times for Various Eggs

Figure 9: Incubation Times.
- Chicken: 21 days
- Duck: 28 days
- Goose: 30 days
- Pigeon: 18 days
- Quail: 18 days
- Peacock: 28 days
The incubation period is divided into two stages: early and late. The late stage refers to the last 3 days of the incubation period. Remove the hatching net in the early stage, and remove the egg tray in the last three days before placing eggs in the hatching net.
For beginners, using chicken eggs as an example: maintain a constant temperature of 37.8°C throughout. Add 1-2 pots of water daily. Humidity should be around 60% in the early stage and about 75% in the late stage.
6.4.3 Water Injection
There are two water injection holes on the side of the machine. Use a kettle to add 50-100mL of water to the smallest grid of the water tank. If humidity is insufficient, add water to other grids sequentially. The amount of water needed varies by ambient humidity and machine size. If humidity is consistently below 50%, add water appropriately. Occasional fluctuations in humidity are normal, but prolonged high or low humidity should be avoided.
6.4.4 Spraying or Cooling Eggs (Late Stage)
After 18 days of incubation (for chicken eggs), use a watering can with 40°C warm water to spray a fine mist over the eggs a few times, once in the morning and once in the afternoon. After spraying, open the machine lid to cool the eggs for about 5-10 minutes, then close the lid. If the eggs are not warm to the touch, cooling may not be necessary.
6.4.5 Final Stage (Last 3 Days)
In the last three days, transfer the eggs from the egg tray to the hatching net. At this point, automatic egg turning is no longer needed. Ensure humidity reaches about 75% to prevent the eggshell from becoming too hard, which could hinder hatching. Once chicks hatch and their feathers dry, remove them from the incubator. Place them in a cardboard box with a light bulb for slow de-warming and brooding. This process typically takes 7-10 days, with a de-warming temperature of about 30°C.
6.5 Common Parameters & Factory Reset
- "+" button: Manual egg flip button.
- "-" key: Cancels the alarm.
- Factory Reset: Press and hold the "+" and "-" keys simultaneously for more than 5 seconds.
7. Maintenance
- Cleaning: Disconnect power before cleaning. Use a soft, damp cloth to wipe the exterior of the thermostat. Do not use abrasive cleaners or immerse the unit in water.
- Probe Care: Keep temperature and humidity probes clean and free from debris for accurate readings.
- Storage: When not in use, store the thermostat in a dry, cool place away from direct sunlight and extreme temperatures.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Temperature Alarm | Temperature outside 37.0°C - 38.6°C range. | Check heating element, ambient temperature, and probe connection. Adjust settings if necessary. Press '-' to cancel alarm. |
| Humidity Alarm | Humidity outside 40% - 75% range. | Check water levels in the tank, humidifier function, and probe connection. Adjust water as needed. Press '-' to cancel alarm. |
| Egg Turning Not Working | Motor issue, incorrect settings, or power supply problem. | Check motor connection. Verify egg turning cycle and time settings. Ensure 12V power supply to the motor. |
| Display Not Working | No power or internal fault. | Check power connection and source. If problem persists, contact support. |
9. Specifications
| Feature | Specification |
|---|---|
| Model | ZFX-9002 |
| Display Type | DIGITAL |
| Temperature Range | 0°C ~ 99.9°C |
| Humidity Range | 0 ~ 99%RH |
| Power Supply | DC 12V or AC 110-220V (model dependent) |
| Egg Turning Cycle | 0-999 minutes (Default: 120 minutes) |
| Egg Turning Time | 0-999 seconds (Default: 15 seconds) |
| Dimensions (approx.) | 150mm x 88mm |
| Battery Included | No |
| Certification | CE |
10. User Tips
- Always perform the initial machine test to ensure all components are working correctly before placing eggs.
- Double-check all wiring connections, especially for the heating element, humidifier, fan, and motor, to ensure proper functionality.
- Monitor the incubator regularly, especially during the first few days, to ensure stable temperature and humidity.
- For optimal performance, ensure the incubator is placed in a stable environment away from drafts or direct sunlight.
11. Warranty & Support
For any questions, technical support, or warranty inquiries, please refer to your purchase documentation or contact the seller directly. Keep your proof of purchase for any warranty claims.