1. Introduction

This meter is a portable smart meter that intelligently recognizes DC voltage, AC voltage, resistance, on-off buzzer, and automatically switches to the corresponding range. Ordinary users can easily measure various electrical parameters without professional knowledge of physics. The large-screen LCD display and 4000-count display make readings more accurate. It meets the safety standards of IEC 61010 for 600V CAT II and pollution degree 2.

NJTY T1 Multimeter in hand, showing display

Figure 1: NJTY T1 Smart Mini Digital Multimeter in use.

2. Safety Information

2.1 Safety Instructions

When using this meter, the user must comply with all standard safety regulations concerning:

  1. Protection against electric shocks.
  2. Preventing the misuse of the instrument's safety procedures.

To ensure personal safety, always use the test pens provided with the meter. Check them before use to ensure they are intact.

2.2 Safety Symbols

Symbol Description
⚠Warning
∼AC (alternative current)
—DC (direct current)
⟘Ground
□Double insulation
CEEuropean Union standard
⚡High voltage warning
CAT IIII category overvoltage protection

2.3 Safety Notices

  • The use of meter instruments near devices with large electromagnetic disturbances will be unstable and may even cause large errors.
  • Do not use the meter if its appearance or the test pen is broken.
  • If the meter is not used correctly, its safety functions may fail.
  • Care must be taken when working around bare conductors or buses.
  • Do not use this instrument near explosive gas vapor or dust.
  • The correct input function must be used to measure the range.
  • The input value must not exceed the limit specified for each range to prevent damage.
  • Do not touch the unused input when the instrument is connected to the circuit under test.
  • When the measured voltage exceeds 60 VDC or 30 VAC, use caution to prevent electric shock.
  • When measuring with a test pen, place your finger behind the guard ring of the test pen.
  • Before converting the range, ensure that the test pens have left the circuit under test.
  • Before resistance, diode, capacitance, or continuity tests, the circuit under test must be powered off and all high-voltage capacitors discharged.
  • Do not measure resistance on a live circuit or perform a buzzer test on a live circuit.
  • Before current measurement, the meter's fuse should be checked.

3. Product Overview

3.1 Symbols on Panel

Labeled diagram of the NJTY T1 Multimeter with buttons and ports identified

Figure 2: NJTY T1 Multimeter Panel Layout

  1. NCV sensing area
  2. Illumination
  3. LCD display
  4. Buzzer & NCV indicator
  5. Backlight and Illumination button
  6. Power button
  7. V/Ω input socket
  8. COM input socket
  9. Data hold and NCV button

3.2 Symbols on Screen

Symbol Description
⚠Battery low voltage display
⏸Auto power off
—Negative polarity input indication
ACAlternative input indication
DCDirect input indication
★In continuity test mode
AUTOAuto ranging mode
HData hold mode
VVoltage unit
Ω, kΩ, MΩResistance unit

4. Setup

4.1 Battery Installation

The instrument uses two AAA 1.5V batteries as the power supply. The battery must be properly installed in the battery compartment of the meter.

  1. Turn off the power of the instrument and pull all test pens out of the input socket.
  2. Use a screwdriver to loosen the screws fixing the battery cover.
  3. Remove the battery cover and take out the old batteries.
  4. Replace with new 2*1.5V AAA batteries, ensuring correct polarity.
  5. Install the battery cover and close the screws.
Multimeter with red and black test leads connected

Figure 3: Multimeter with test leads connected.

5. Operating Instructions

5.1 ACV/DCV/Resistance/Buzzer Measurement

  1. Connect the black test pen to the COM jack and the red test pen to the V/Ω jack.
  2. Turn on the meter by pressing the power key.
  3. Connect the test leads to the circuit to be tested (for power or resistance). The meter will automatically judge ACV, DCV, continuity, or resistance.
  4. If the resistance of the circuit under test is not greater than about 50 ohms, the indicator light will turn on and the buzzer will sound continuously.
  5. The screen also shows the polarity of the red test pen as well as the surrounding temperature when DCV is measured.
Two images showing AC voltage measurement (227.4 ACV) and DC voltage measurement (9.81 DCV) with test leads

Figure 4: AC and DC Voltage Measurement Examples.

5.2 NCV Non-Contact Voltage Detection

The NCV function detects voltage without contact. The strength of the signal is indicated by '----' (from weak to strong).

  1. Turn on the meter by pressing the power key.
  2. Press the H/NCV button constantly and test when "EF" is shown on the screen.
  3. The NCV indicator flashes with a buzzer when there is voltage on the live wire. The screen shows the magnetic field strength and indicates from '--' to '----' according to the signal strength.

Note:

  • Voltage may still be present even if the NCV indicator's buzzer does not flash, due to socket design or insulation.
  • External factors like flashlights or radar may cause NCV flashes.

5.3 Backlight and Flashlight Function

The meter has backlight and illumination functions for convenient reading in dark situations.

  1. Short press the ★/⚡ key to turn on the backlight. Short press again to turn it off. It turns off automatically after 30 seconds of no operation.
  2. Long press the ★/⚡ key to turn on both the illumination function (flashlight) and the backlight. Short press the key again to turn off both. They turn off automatically after 30 seconds of no operation.
  3. When the backlight is on, pressing the key for 2 seconds can also start the illumination. Both will turn off after 30 seconds of no operation.
Multimeter flashlight in use, illuminating a dark area

Figure 5: Multimeter flashlight in operation.

5.4 Auto Power Off

After about 5 minutes of inactivity after power on, the instrument will give audible voice prompts and automatically cut off power.

6. Specifications

6.1 General Specifications

  • Operating conditions: 600V CAT II, Pollution degree 2, Height under 2000m
  • Working temperature: 0-40℃ (<80%RH)
  • Storage temperature: -10-60℃ (<70%RH, remove battery)
  • Test/calibrate surrounding temperature: 20℃ ± 2℃
  • Maximum voltage between measurement end and ground: 600V
  • Conversion rate: about 3s/second
  • Display: 4000 counts LED display
  • Overload: 'OL' displayed
  • Low voltage display: ⚠ displayed when working voltage is low
  • Input polarity indicator: '-' shown automatically
  • Battery: 2 x 1.5V AAA
  • Size: 123mm (L) x 61mm (W) x 24mm (H)
  • Weight: about 78g (battery excluded)
Dimensions of the NJTY T1 Multimeter (4.8in H, 2.4in W, 1in D)

Figure 6: Multimeter Dimensions.

6.2 Measurement Specifications

Function Range Resolution Accuracy Note
DCV0.8V-600V0.001V±(0.8%+5)Min Input: 0.8V, Max Input: 600V, Resistor Impedance: 10M
ACV1V-600V0.001V±(1.0%+5)Min Input: 1V, Max Input: 600V, Resistor Impedance: 10M
Resistance0Ω-40MΩ1Ω±(1.0%+10)Protection: 600V AC/DC
Max display4000
Auto Power-off√No operation for 5 minutes
Backlight√Turn off after 30 seconds
Illumination√Turn off after 30 seconds
BuzzerProtection: 600V AC/DC
Buzzer Indicator√
NCV√'----' refers to change from strong to weak
NCV Indicator√
True RMS√45Hz-2KHz
Low Battery√

7. Maintenance

7.1 General Maintenance

  • When opening the instrument case or removing the battery cover, always pull out the test pens first.
  • Only specified replacement parts must be used to service the meter.
  • Before opening the meter, all relevant power sources must be disconnected. Ensure no static electricity is present to avoid damage.
  • Instrument components, calibration, and maintenance operations should be performed by professionals.
  • When opening the instrument housing, be aware that dangerous voltages may persist even after the instrument is turned off due to capacitance.
  • If any abnormality is observed, stop using the meter immediately and send it for repair. Do not use it until it has been inspected and qualified.
  • If not in use for a long time, remove the batteries and avoid storing in high temperature and humidity.

7.2 Battery Replacement

When the low voltage battery symbol ⚠ appears, replace the battery immediately. Insufficient battery power can lead to incorrect readings, electric shock, or personal injury. Follow the steps in Section 4.1.

8. Troubleshooting

  • Incorrect Readings: If readings are incorrect, check for low battery indicated by the ⚠ symbol and replace batteries if necessary.
  • Meter Not Functioning: Ensure the meter's housing is intact. Do not use if any part of the housing is removed.
  • "EF" Display during NCV Test: This indicates the NCV function is active and detecting. If it persists or behaves unexpectedly, refer to the NCV section in operating instructions.
  • Unstable Readings: Avoid using the meter near devices with large electromagnetic disturbances, as this can cause unstable or erroneous readings.
  • NCV Indicator Not Flashing but Voltage Present: This can occur due to socket design or insulation. Always exercise caution when working with electrical circuits.

9. User Tips

  • This multimeter is very practical and provides accurate measurements for both AC and DC voltage.
  • It's well-suited for home use due to its automatic function switching.
  • The NCV (Non-Contact Voltage) feature can be used to quickly check for live wires in walls or outlets.
  • The device is generally easy to use, even for those without extensive electrical knowledge.

10. Warranty & Support

This product comes with a one-year warranty from the manufacturing date, covering accuracy (±%reading+digit) under specified conditions (surrounding temperature 18℃ to 28℃, <80%RH).

For detailed warranty information, troubleshooting, or further assistance, please refer to the complete user manual available as a PDF: Download Full User Manual (PDF).

11. Frequently Asked Questions (FAQ)

Q: What category does this product belong to?
A: This product belongs to the electrical category.

12. Accessories

The product package typically includes:

  • 1 x Instruction Manual
  • 1 x Pair of Test Leads
  • 2 x AAA Batteries (for operation)
  • 1 x Temperature Probes (if included with specific model variant)