1. Introduction
The INA226 is a high-side or low-side bidirectional current/power monitor with an I2C-compatible interface. This device precisely monitors both shunt voltage drops and bus power supply voltages, enabling direct current and power readings in amperes and watts through programmable calibration values and an internal multiplier. It is designed for a wide range of applications requiring accurate current and voltage measurement.
2. Product Overview
2.1 Key Features
- I2C™ Current splitters and power monitors with SMBUS compatible interfaces.
- Simultaneously monitors parallel voltage drop and bus power supply voltage.
- Programmable calibration values, conversion time, and average values.
- Directly reads current in amperes and power in watts.
- Senses current on common mode bus voltage, ranging from 0 V to 36 V.
- Powered by a single power supply from 2.7V to 5.5V.
- Typical power consumption of 330 µA.
- Rated operating temperature range: -40°C to 125°C.
- Up to 16 programmable I2C addresses.
2.2 Product Variants
The INA226 module is available in two main configurations:
- Unwelded Kit: Includes the module, 2x needle arrangements (pin headers), and 1x terminal block, requiring user assembly.
- Welded Module: Comes with components pre-soldered for immediate use.

Figure 1: INA226 Module (Unwelded)

Figure 2: INA226 Module (Welded)
3. Package Contents
3.1 Set 1 (Unwelded)
- 1x INA226 Module PCB
- 2x Pin Header Strips (for VCC, GND, SDA, SCL, ALERT, A0, A1)
- 1x Terminal Block (for INPUT/OUTPUT)

Figure 3: Unwelded Kit Components
3.2 Set 2 (Welded)
- 1x INA226 Module (with pin headers and terminal block pre-soldered)
4. Setup and Connection
4.1 Pinout Description
The module features several pins for power, communication, and alarm output:
- VCC: Power input for the module (2.7V - 5.5V).
- GND: Negative pole of the power supply.
- SDA, SCL: I2C bus data and clock signal lines for communication with a microcontroller.
- ALERT: Multi-functional alarm output pin.
- A0, A1: I2C address line configuration pins.

Figure 4: INA226 Module Pinout
4.2 I2C Address Configuration
The INA226 module supports up to 16 programmable I2C addresses. The address is set by bridging the A0 and A1 solder jumpers to either GND (Ground) or VCC (Power Supply). This allows multiple INA226 modules to be used on the same I2C bus.
| A1 | A0 | I2C Address (hex) |
|---|---|---|
| GND | GND | 0x40 (Default) |
| GND | VCC | 0x41 |
| VCC | GND | 0x44 |
| VCC | VCC | 0x45 |

Figure 5: I2C Address Configuration via Solder Jumpers
4.3 Wiring Instructions
Connect the module to your microcontroller and the circuit you wish to monitor as follows:
- Power Connection: Connect VCC to your power supply (2.7V-5.5V) and GND to the common ground.
- I2C Communication: Connect SDA and SCL pins to the corresponding I2C pins on your microcontroller.
- Current/Voltage Measurement:
- The positive pole of the VIN power supply measures voltage.
- The negative pole of the CND power supply measures voltage.
- The VOUT measures current input and output.
- Connect the circuit to be monitored to the INPUT and OUTPUT terminals.
- Alarm Output (Optional): Connect the ALERT pin to an interrupt-capable pin on your microcontroller if you plan to use the alarm functionality.

Figure 6: Example Setup - Module Initialization

Figure 7: Example Setup - Multiple Modules in a Complex Circuit
5. Operation
Once connected, the INA226 communicates via the I2C interface. You will need to program your microcontroller to interact with the module. The INA226 allows for:
- Reading shunt voltage and bus voltage.
- Calculating current and power using internal registers and programmable calibration values.
- Configuring conversion times and averaging modes for measurements.
- Setting up alert thresholds for overcurrent, undervoltage, etc.
For detailed programming instructions and register maps, please refer to the official INA226 datasheet or the provided user manual PDF: User Manual (PDF).

Figure 8: Example Operation - Displaying Measurements on OLED
6. Specifications
| Parameter | Value |
|---|---|
| Model Number | INA226 |
| Type | Monitor Alarm Power Meter |
| Measurement Voltage | 0 V to 36 V (DC, negative voltage cannot be measured) |
| Measuring Current | -20A to +20A (Bidirectional) |
| Power Supply Voltage (VCC) | 2.7V to 5.5V |
| Interface | I2C |
| I2C Addresses | 16 (configurable via A0, A1 solder jumpers) |
| Input Offset Voltage | ± 10 µV |
| Precision | 1% |
| Resolution | 16 bits (Current: 1.25mA, Voltage: 1.25mV) |
| Current Consumption | Below 1mA |
| Dimensions | 20mm x 27mm (with 3mm fixed hole) |
| DIY Supplies | Electrical |
| Certification | CE |

Figure 9: Dimensional Drawing of the INA226 Module
7. Important Considerations
- This module is designed to measure DC power supplies only.
- The maximum current that can be measured should not exceed 20A.
- The maximum voltage for measurement is 36V.
- Ensure the VCC voltage for the module itself is within 2.7V to 5.5V.
- Always refer to the full data manual for comprehensive technical details and safety guidelines.
8. User Tips
- Parallel Usage: Multiple INA226 modules can be used in parallel on the same I2C bus by configuring their unique I2C addresses using the A0 and A1 solder jumpers.
- Address Modification: While possible, modifying the I2C address by moving SMD resistors can be challenging due to their small size. Exercise caution or seek professional assistance if you are not experienced with SMD soldering.
- Assembly: If you purchased the unwelded kit, ensure all components are correctly soldered before attempting to power on or connect to a circuit.
9. Troubleshooting
- No Readings: Double-check all wiring connections, especially VCC, GND, SDA, and SCL. Verify the I2C address in your code matches the module's configuration.
- Incorrect Readings: Ensure your calibration values in the microcontroller code are correctly set according to the INA226 datasheet. Check for proper shunt resistor connection.
- Module Not Detected: Confirm the module is powered correctly (VCC within 2.7-5.5V). Use an I2C scanner sketch to verify the module's presence on the bus and its address.
- Overcurrent/Overvoltage: If the module is not providing expected readings or behaving erratically, ensure the measured current and voltage are within the specified limits (-20A to +20A, 0V to 36V).
10. Maintenance
- Keep the module clean and free from dust and moisture.
- Avoid exposing the module to extreme temperatures or direct sunlight.
- Handle with care to prevent physical damage to the components or solder joints.
- Regularly check connections for looseness or corrosion, especially in high-vibration environments.
11. Warranty and Support
For warranty information, technical support, or further inquiries, please contact the seller or manufacturer directly. Additional technical documentation, including the full datasheet, can be found in the provided PDF manual: User Manual (PDF).