1. Introduction
The diymore OPTLB03 is an industrial-grade UART isolated communication module designed to convert RS485 signals to TTL232 and vice versa. It features robust surge protection and optocoupler isolation, making it suitable for demanding industrial control environments and various microcontroller applications like Arduino. This manual provides detailed instructions for its setup, operation, and maintenance.
2. Features
- Wide range of applications
- Compact size
- Stable performance
- Simple to use
- Available with or without pins (optional)
- RS485 to TTL232 isolation communication surge protection
- TVS anti-surge protection
- Industrial grade RS485 chip
- 3000V digital isolation for RX/TX signals
- Optocoupler isolation for R/D signal
3. Specifications
| Parameter | Value |
|---|---|
| Working Voltage | DC 5V (4.5-5.5V) |
| Working Current | <2mA |
| Communication Rate (Baud Rate) | 100-256000 BPS |
| TTL Level | 5V |
| Surge Protection | TVS Anti-Surge Protection |
| RS485 Chip | Industrial Grade |
| Digital Isolation | 3000V (RX/TX signals) |
| Optocoupler Isolation | R/D signal |
| Operating Temperature | -40°C to 85°C |
| Dimensions | 29 x 16 x 7mm |
| Weight | Approximately 2g |
| Type | Voltage Regulator |
| Application | Computer, RS485 to TTL, PLC industrial control equipment |
4. Package Contents
- 1 x Industrial RS485 to TTL232 UART Isolated Communication Surge Protection Module
5. Setup
The OPTLB03 module can be powered using either one or two separate 5V DC power supplies, depending on your application's isolation requirements. Ensure all connections are secure before applying power.
5.1 Pin Description
Refer to the diagram below for pin identification and their functions:

- S5V: RS485 Power + (Positive supply for the RS485 side)
- SGND: RS485 Power - (Ground for the RS485 side)
- A+: RS485 A+ data line
- B-: RS485 B- data line
- T5V: TTL Power + (Positive supply for the TTL side)
- TGND: TTL Power - (Ground for the TTL side)
- R/D: Data flow control signal (Usually set to low level; set to high level when TTL sends data)
- RX: TTL RXD (Connect to MCU RXD pin)
- TX: TTL TXD (Connect to MCU TXD pin)
5.2 Wiring Diagrams
The module supports two primary wiring configurations for power supply:

- Using Two Separate Power Supplies: Connect a DC 5V power supply to the S5V and SGND pins for the RS485 network. Connect a separate DC 5V power supply to the T5V and TGND pins for the TTL side (e.g., MCU). This configuration provides full electrical isolation between the RS485 and TTL sides.
- Using Only One Power Supply: Connect a single DC 5V power supply to both S5V/T5V (positive) and SGND/TGND (ground). In this setup, the isolation between the power grounds is maintained, but the power source is shared.
5.3 Example Connection with Arduino
Below is an example of connecting the OPTLB03 module to an Arduino board:

Connections:
- Arduino 5V <-----> T5V & S5V (Power for both sides)
- Arduino GND <-----> TGND & SGND (Ground for both sides)
- Arduino Digital Pin 2 <-----> R/D (Data direction control)
- Arduino TX (Pin 1) <-----> Module TX
- Arduino RX (Pin 0) <-----> Module RX
For the RS485 bus, connect A+ and B- to your RS485 network.
6. Operating Instructions
Once the module is correctly wired and powered, it acts as a transparent converter between RS485 and TTL232 signals. The key to proper operation is managing the R/D (Receive/Drive) pin.
- Receive Mode: For the module to receive data from the RS485 bus and convert it to TTL, the R/D pin should typically be held at a low logic level.
- Transmit Mode: When the TTL side (e.g., your microcontroller) needs to send data to the RS485 bus, the R/D pin must be set to a high logic level. After transmitting the data, the R/D pin should be returned to a low level to allow the module to receive data again.
The communication rate (baud rate) must be configured identically on both the RS485 and TTL sides, within the supported range of 100-256000 BPS.
7. User Tips
- Always double-check your wiring before applying power to prevent damage to the module or connected devices.
- For optimal noise immunity and isolation, consider using two separate power supplies if your application allows.
- Ensure the R/D pin control logic in your microcontroller code is correctly implemented to avoid data collisions or missed transmissions.
- When troubleshooting, verify the baud rate settings on all communicating devices.
8. Maintenance
The OPTLB03 module is designed for robust operation and requires minimal maintenance. To ensure its longevity and reliable performance:
- Keep the module in a dry environment, away from moisture and corrosive substances.
- Avoid exposing the module to extreme temperatures outside its specified operating range (-40°C to 85°C).
- Periodically inspect connections for any signs of wear or corrosion.
- Clean the module gently with a soft, dry cloth if dust accumulates. Do not use liquids or harsh chemicals.
9. Troubleshooting
If you encounter issues with the OPTLB03 module, consider the following troubleshooting steps:
- No Communication:
- Verify all power connections (S5V, SGND, T5V, TGND) are correct and receiving the appropriate 5V DC.
- Check the RS485 A+ and B- connections for correct polarity.
- Ensure the TTL RX and TX pins are correctly connected to your microcontroller's TX and RX pins, respectively.
- Confirm that the baud rate settings on all communicating devices match the module's supported range.
- Intermittent Communication:
- Check the R/D control signal. Incorrect timing or logic for switching between transmit and receive modes can cause data loss.
- Ensure the power supply is stable and provides sufficient current.
- Inspect for loose connections or damaged wiring.
- Module Not Responding:
- Disconnect all data lines and check if the module powers on correctly (if applicable, check for any indicator LEDs).
- If possible, test the module with a known working setup or a different power supply.
10. Warranty and Support
This diymore OPTLB03 module is designed for reliability. For technical support or inquiries, please contact your retailer or refer to the official diymore support channels. A user manual in PDF format is also available for download from the product page for more detailed information.