1. Introduction
This manual provides detailed instructions for the safe and efficient operation of your Gaqqee XY5005E/XY5008E DC-DC Buck Converter. Please read this manual thoroughly before use and keep it for future reference.
The Gaqqee XY5005E/XY5008E is a versatile constant voltage (CV) and constant current (CC) DC-DC buck power supply module. It features a large screen display for clear monitoring, simple operation, and stable performance, making it suitable for computer power modification, DIY desktop power projects, and laboratory use.
2. Safety Information
Always observe the following safety precautions to prevent injury or damage to the device:
- Ensure the input voltage is within the specified range (6.0-55V) to avoid damage.
- Do not exceed the maximum output current (5.000A for XY5005E, 8.100A for XY5008E) or output power (250W for XY5005E, 400W for XY5008E).
- Verify all connections are correct and secure before applying power.
- Avoid touching exposed components when the device is powered on.
- Operate the device in a well-ventilated area to ensure proper heat dissipation.
- This device is not galvanically isolated between input and output. Exercise caution when connecting to other circuits.
3. Product Overview
3.1. Features
- High-quality materials ensure reliability.
- Large screen display provides clear visibility of various statuses.
- Simple operation for a smooth user experience.
- One-piece matte panel with high-quality aluminum alloy knob cap.
- Intelligent temperature control fan for automatic start/stop, coupled with a thickened heat sink for efficient two-way ventilation.
- Exquisite appearance and user-friendly design.
3.2. Components and Interface
The module features a robust design with key components for stable operation and user interaction.


3.3. Product Interface Function Details
The display provides comprehensive information and allows for various settings:

4. Setup
4.1. Wiring
Connect the input and output wires to the pluggable cable terminals as shown in the diagram. Ensure correct polarity: input Positive pole, input Negative pole, output Positive pole, and output Negative pole.

4.2. Mounting
The module is designed for easy integration into custom enclosures. Refer to the dimensions below for the suggested opening size.

5. Operating Instructions
5.1. Setting Voltage and Current

- Enter Setting Interface: In the operation interface, press the
V/Abutton to enter the setting voltage and current interface. The LCD will display 'SET', and 'CV' will flash. - Set Voltage: Press the
SWbutton or rotate the encoder to select the voltage bit. Adjust the set voltage by rotating the encoder. - Set Current: Press the
V/Abutton again. The LCD will display 'CC' flashing. Press theSWbutton or rotate the encoder to select the current bit. Adjust the set current by rotating the encoder. - Exit and Save: Press the
V/Abutton again to exit and save the settings, returning to the operating interface. Alternatively, long press theV/Abutton for 2 seconds or wait for 6 seconds without any key operation; the system will automatically exit and save.
5.2. Quick Setting of Voltage or Current

In the parameter setting interface (see section 5.3), set the parameter 'FET' to 'CV' or 'CC'. Then, rotate the encoder in the operation interface to quickly set the voltage or current.
5.3. Parameter Setting Screen

- Enter Parameter Setting: On the running screen, hold down the
SWbutton for 3 seconds to enter the parameter setting screen. - Navigate Parameters: Press the
SWbutton to switch between parameters. Press the encoder button to select the bit, then rotate the encoder to adjust the value. - Enable/Disable Functions: On the OAH/OPH/OHP interfaces, press the
ON/OFFbutton to enable or disable the corresponding function. If disabled, '----' will be displayed. - Capacity/Energy Range: On the OAH/OPH screen, hold down the
ON/OFFbutton to select the capacity range (e.g., 9.999Ah, 99.999Ah, 9999Ah, 9.999Wh, 99.999WH, 9999Wh). - Exit and Save: After setting parameters, hold down the
SWbutton for 2 seconds to exit. Settings are automatically saved.
5.4. Input and Output Voltage Display

Press the SW button on the running interface to toggle between displaying the input voltage and output voltage.
5.5. View Power (W), Capacity (Ah), Energy (Wh), Time (h)

In the operation interface, short press the encoder button to cycle through the display of power (W), capacity (Ah), energy (Wh), and time (h).
5.6. Locking Function

In the operation interface, long press the encoder button for 2 seconds to lock the voltage and current settings, preventing misoperation. A lock symbol will appear on the display. To unlock, long press the encoder button for 2 seconds again.
6. Specifications
| Attribute | XY5005E | XY5008E |
|---|---|---|
| Product Name | CNC DC Step-Down Power Supply | |
| Input Voltage | 6.0~55V | |
| Output Voltage | 0.0~50V | |
| Output Current | 0.000~5.000A | 0.000~8.100A |
| Output Power | 0~250W | 0~400W |
| Voltage Accuracy | +0.4% + 1 word | |
| Current Accuracy | +0.5% + 3 words | |
| Voltage Resolution | 0.01V | |
| Current Resolution | 0.001A | |
| Conversion Efficiency | About 95% | |
| Soft Start | Yes | |
| Input Anti-Reverse Connection | Yes | |
| Output Short-Circuit Protection | Yes | |
| Input Undervoltage Protection (LVP) | 4.8-30V adjustable (default 4.8V) | |
| Output Overvoltage Protection (OVP) | 0-52V adjustable (default 52V) | |
| Output Overcurrent Protection (OCP) | 0-5.0A adjustable (default 5.0A) | 0-8.2A adjustable (default 8.2A) |
| Output Overpower Protection (OPP) | 0-250W adjustable (default 250W) | 0-410W adjustable (default 410W) |
| Over-Temperature Protection | Yes (default 100°C) | |
| Timeout Protection (OHP) | 0-100H adjustable (off by default) | |
| Overcapacity Protection (OAH) | 0-9999AH adjustable (off by default) | |
| Super Energy Protection (OPH) | 0-9999WH adjustable (off by default) | |
7. Maintenance
- Cleaning: Keep the module clean and free from dust. Use a soft, dry cloth for cleaning.
- Ventilation: Ensure the fan and heat sink are not obstructed to allow for proper airflow and heat dissipation.
- Capacity/Energy/Running Time Statistics: The module automatically records these statistics. To clear the data, press and hold the
ON/OFFbutton for 2 seconds on the corresponding screen. - Firmware Updates: Check the manufacturer's website for any available firmware updates.
8. Troubleshooting
- Inaccurate Output Voltage: If the output voltage appears inaccurate, verify it with an external multimeter.
- Rotary Encoder Jumps Values: If the rotary encoder is not adjusting values progressively (e.g., jumping from 1 to 7 then to 2), try rotating it more slowly. Ensure there is no debris obstructing the encoder mechanism.
- Over-Temperature Protection Triggered: If the fan is running continuously or the device shuts down due to over-temperature, ensure adequate ventilation and that the heat sink is not blocked. Reduce the load if necessary.
- Protection Functions (OAH/OPH/OHP) Triggered: If the power supply automatically shuts down, check if the Overcapacity (OAH), Super Energy (OPH), or Timeout (OHP) protection functions are enabled and their set limits have been reached. Clear the alarm and adjust settings if needed.
- No Display/No Power: Check input power connections and ensure the input voltage is within the specified range.
9. User Tips
- For critical applications, always verify the output voltage and current with a calibrated external multimeter to ensure precision.
- When adjusting parameters with the rotary encoder, especially for fine adjustments, rotate it slowly to prevent values from jumping unexpectedly.
- Ensure your input power supply is compatible with the module's input voltage range (6.0-55V).
- Consider the module's power rating (250W for XY5005E, 400W for XY5008E) when designing your project to avoid overloading.
10. Frequently Asked Questions (FAQ)
- Q: Is there a galvanic isolation between the input and output?
- A: No, this DC-DC buck converter typically does not provide galvanic isolation between the input and output. Exercise caution when integrating it into circuits where isolation is required.
- Q: Is the display backlight adjustable?
- A: The provided information does not indicate that the display backlight is adjustable. It operates at a default brightness level.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.
You can also refer to the official user manual PDF for additional details: View User Manual (PDF)