1. Introduction

The ATORCH DL24/DL24P is a versatile electronic load tester designed for battery capacity testing, DC power supply monitoring, and various other electrical measurements. It features a 2.4-inch HD color screen, Bluetooth connectivity for PC and mobile app control, and supports multiple testing modes including Constant Current (CC), Constant Voltage (CV), Constant Power (CP), and Constant Resistance (CR).

This manual provides detailed instructions for the setup, operation, maintenance, and troubleshooting of your DL24/DL24P device. Please read it carefully before use.

For a downloadable PDF version of the user manual, please refer to the official documentation: DL24/DL24P User Manual (PDF)

2. Product Overview

The DL24/DL24P electronic load tester is equipped with a fan that starts when powered on, stops during standby, and resumes operation during testing. Key components and interfaces are described below:

DL24/DL24P Front View

Image: Top-down view of the DL24/DL24P Tester showing the display and controls.

Key Interfaces and Controls:

  • Product Power Supply Input Port (12V/1A): For powering the device.
  • DC5.5 Test Input: For DC power supply connections.
  • Mini USB Test Input: For Mini USB connections.
  • Micro USB Test Input: For Micro USB connections.
  • Type-C Test Input: For Type-C connections.
  • External Temperature Probe Interface: For connecting an external temperature sensor.
  • PC Online Connection Interface: For connecting to a computer.
  • Set Button: Short press to move the slider, long press for detailed input mode and values.
  • +/- Buttons: For adjusting values.
  • Start Button (ON/OFF): Short press to start/stop, long press to access system background.
  • Built-in Bluetooth: For wireless connectivity.
  • System Speaker: For audio feedback.
  • Integrated Discharge Tube Temperature Display: Shows internal temperature.
  • Battery Internal Resistance Test: Functionality for measuring battery internal resistance.

3. Setup

3.1 Power Supply Instructions

The DL24/DL24P does not include a power adapter. It can be powered by one of three methods:

  1. DC5.5-12V Power Supply: Insert into the device's DC5.5 interface.
  2. USB-5V/2A Charger Power Supply: Insert into the device's CC port.
  3. QC/PD Protocol 12V Charger Power Supply: Insert into the device's CC port.

Attention: A DC12V power supply is required for the device to function correctly.

3.2 Product Wiring Methods

The electronic load supports both 2-wire and 4-wire wiring methods for testing.

Electronic Load Wiring Diagram

Image: Diagram illustrating two-wire and four-wire connection methods.

  • Two-wire wiring method: This method is simple and convenient. Connect to the A+ and A- terminals.

  • Four-wire wiring method: This method provides more accurate voltage measurements as it is not affected by the voltage drop of the wires. It is recommended for users with a basic understanding of circuits.

3.3 Included Accessories

The standard package includes the following accessories:

  • Measuring Line Adapter Board Measuring Line Adapter Board: Used for testing DC power supply, Mini USB, Type-C, and Android USB data cables.
  • Temperature Probe Temperature Probe: For measuring battery temperature and detecting the temperature of various devices.
  • 10A 2-wire Test Cable 10A 2-wire Test Cable: For detecting batteries or other 10A wiring equipment within range.
  • Computer Online Cable Computer Online Cable: For connecting to a computer to use software for firmware upgrades and data reading.
Unboxed DL24 Tester and Accessories

Image: Contents of the DL24/DL24P package, including the tester and various cables/adapters.

4. Operating Instructions

4.1 Menu Navigation

To navigate the device's menu:

  • Press and hold the "OK/Start" button from the measurement interface to return to the menu options interface.
  • Short press the "+"/"-" buttons to move to the "System Settings" icon when it turns green.
  • Short press again to enter the system settings interface.
  • Short press the "+"/"-" buttons to select a column and enter parameters for the corresponding function settings.
DL24 System Settings Menu

Image: DL24 System Settings Menu (Version 1.1) showing various configuration options.

4.2 Test Modes

The DL24/DL24P supports four main functional testing modes:

Test Mode Operation Instructions
Constant Current (CC) Mode Select "CC" mode, set the cut-off voltage and discharge parameters. Press "OK/Start" to begin constant current discharge at the set value.
Constant Voltage (CV) Mode Set to "CV" mode. The tested power supply must be a constant current power supply. The device will operate at the set voltage value for constant voltage discharge. (Note: CV mode cannot test batteries.)
Constant Power (CP) Mode Set to "CP" mode. The device automatically calculates the current-to-voltage ratio and works at a set power value for constant power discharge. Can be combined with a high-voltage trigger to test charger maximum power. (Note: CP mode cannot test batteries.)
Constant Resistance (CR) Mode Set to "CR" mode. The device automatically calculates based on the set resistance value. The ratio of voltage to current equals a constant resistance value for discharging.

4.3 PC and Bluetooth APP Functions

The DL24/DL24P supports PC software and Bluetooth mobile applications for enhanced control and data logging.

  • PC Software: Connect via HID data cable. The PC software can read device current, voltage, power, capacity, and other data, and export data to XLS tables. It supports Windows 7 and Windows 10. Download link: PC Software Download

  • Bluetooth APP: Supports Android 5.0 and above, and iOS. The app can read device current, voltage, power, capacity, and other data, and export XLS table data. This app is primarily for controlling switches and may have compatibility issues; it is not intended for primary testing. PC software is recommended for testing.

    • Android APP: Search "E-test" on Google Play. Download link: Android APP Download
    • iOS APP: Search "E_test" on the iPhone App Store.
    • Connection: Ensure Bluetooth is enabled on your phone. Open the E-test APP, click the Bluetooth icon, and select the DL24-BLE device.
    • Important Note: When online, ensure GPS positioning permission is enabled. Some phones (e.g., Samsung) may have compatibility issues; if so, try another phone for pairing.
    Bluetooth APP Interface

    Image: Screenshots of the E-test Bluetooth APP interface on a mobile phone.

5. Specifications

Feature Specification
Model Number DL24
Type Household Battery Tester / Electronic Load
DIY Supplies Electrical
Certification CE, RoHS
Voltage Range 2~200V
Current Range 0.2~20A
Power Range (DL24) 0~150W
Power Range (DL24P) 0~180W
Fan Working Intelligent control, turns on when powered on.
Fan Turn OFF Set standby time; fan stops when standby time reached.
CC Test Mode Constant current
CV Test Mode Constant voltage
CP Test Mode Constant power
CR Test Mode Constant resistance
PC Computer Connection Supported, via data cable or Bluetooth
Electronic Load Wiring Supports 2-wire testing or 4-wire testing
Protection Functions Over-current, Over-power, Over-temperature protection
Product Power Supply DC5.5-12V / USB-5V/2A / QC/PD 12V power supply

Power Testing Range Notes:

  • Voltage < 36V: Maximum testable power of 150W (DL24) / 180W (DL24P)
  • Voltage > 36V, < 80V: Maximum testable power of 60W
  • Voltage > 80V, < 200V: Maximum testable power of 45W
DL24 vs DL24P Comparison

Image: Comparison of DL24 150W and DL24P 180W models, highlighting their power capabilities.

6. Maintenance

  • Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
  • Avoid exposing the device to extreme temperatures, humidity, or direct sunlight.
  • Ensure proper ventilation around the device, especially the fan, during operation to prevent overheating.
  • Store the device in a safe, dry place when not in use.
  • Handle all connections and cables with care to prevent damage to ports and wires.

7. Troubleshooting

  • APP crashes on PC: PC software may have compatibility issues. Download and test the software before purchasing if possible. The PC software only supports Windows 7 and Windows 10.

  • BLE and SPP modes: The APP uses the latest connection technology (BLE). Do not pair in Bluetooth mode directly. For Android, click the E-test APP and then the Bluetooth symbol to select the _BLE Bluetooth name. For iOS, select the _BLE Bluetooth name in the E_test APP. BLE is for mobile mode, SPP is for PC computer mode.

  • Computer pairing password: The password is "0000" or "1234".

  • Incompatible mobile apps: Some phones (e.g., Samsung) may have incompatible apps. If you encounter issues, try pairing and connecting with a different phone.

7.2 Alarm Functions

The device has four major alarm functions to protect against damage:

  • Overload Power Protection (OPP): Triggers if power exceeds 150.0W.
  • Over-current Protection (OCP): Triggers if current exceeds 25.00A.
  • MOS Tube Temperature Over Protection (OTP(Mos)): Triggers if MOS tube temperature exceeds 100.0°C.
  • External Temperature Probe Alarm Protection (OTP(Ext)): Triggers if external temperature exceeds 28.5°C.

If an alarm is triggered, the device will stop operation to prevent damage. Identify and resolve the cause of the alarm before resuming testing.

7.3 General Issues

  • Device not powering on: Ensure a DC12V power supply is correctly connected to the appropriate port (DC5.5, USB-5V/2A, or QC/PD 12V).

  • Readings seem incorrect: Verify wiring connections, especially for 2-wire vs. 4-wire methods. Ensure the correct test mode is selected for your application. If using PC software, ensure it's the latest version and compatible with your OS.

  • Device heats up quickly: Ensure adequate ventilation. The fan should be running during operation. Check if the load power exceeds the specified limits for the current voltage (refer to Power Testing Range Notes in Specifications).

8. User Tips

  • For detailed analysis and data logging, the PC software is highly recommended. It offers more functionality than the mobile app for primary testing.
  • When testing batteries, ensure you set a custom cut-off voltage to prevent over-discharge and damage to the battery.
  • The device is a discharge load and does not support charging batteries.
  • While the device has plastic feet, it is advisable to use it on a flat, isolated surface to ensure stability and prevent accidental short circuits.
  • If you plan to use the device with loads greater than 15A, be aware that it may heat up quickly and trigger protection mechanisms. Ensure your power supply and wiring can handle the intended current.
  • Carefully remove any protective films or rubber bands from the screen area to avoid damage.

9. Warranty and Support

For any technical support, warranty claims, or further inquiries, please contact the seller or manufacturer directly. Refer to your purchase documentation for specific contact information.

This product is certified with CE and RoHS standards.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.