PowMr POW-Keeper Series

Contents

PowMr MPPT Solar Charge Controller User Manual

Models: POW-Keeper1220 (20A), POW-Keeper1230 (30A), POW-Keeper1240 (40A)

1. Introduction

Thank you for choosing the PowMr MPPT Solar Charge Controller. This manual provides essential information for the safe and efficient operation of your solar charge controller. The POW-Keeper series includes 20A, 30A, and 40A models, designed to optimize battery performance and extend battery life through advanced MPPT technology and a three-stage charging algorithm. It is suitable for various 12V or 24V lithium-ion and lead-acid battery systems.

PowMr MPPT Solar Charge Controller in packaging
PowMr MPPT Solar Charge Controller (POW-Keeper Series)

Product Overview Video

This video provides a general overview of the PowMr Keeper series solar charge controllers, highlighting key features and package contents.

2. Safety Information

  • Ensure all connections are secure and correct before operation.
  • This series of MPPT controllers uses a common positive design. The positive poles of the PV array, battery, and load can be grounded simultaneously.
  • If an inverter or other high starting current device is used, connect it directly to the battery, not to the controller's load terminal.
  • Always connect the battery first, then the solar panel, and finally the load. Failure to follow this order can damage the battery.
  • If using lithium batteries, set the system voltage and battery type before use.

3. Package Contents

The PowMr Keeper series package typically includes:

  • PowMr MPPT Solar Charge Controller (20A, 30A, or 40A model)
  • User Manual
  • Installation Guide Card

4. Setup

4.1 Wiring Precautions and Steps

Follow these steps carefully to connect your solar energy system. Incorrect wiring order can lead to damage.

Wiring diagram for PowMr Solar Charge Controller
Wiring Diagram: Connect battery, then load, then solar panels.
  1. Open the cover: First, open the cover to access the screw terminals.
  2. Wire the battery: Connect the battery to the controller terminals first.
  3. Wire the PV array: Connect the solar panels (PV array) to the controller terminals.
  4. Wire the load: Connect your DC load to the controller terminals.
  5. (Optional) Connect the inverter: If using an inverter, connect it directly to the battery, not through the controller's load terminals.

Important: Always connect the battery first, then the solar panel, and then the load. If you do not operate in this order, the battery will be damaged.

4.2 Battery Type Setting

The controller supports various battery types. It is crucial to set the correct battery type for optimal charging and battery longevity. Refer to the table below for available battery types and their corresponding parameters. For lithium batteries, ensure the system voltage is set first.

MPPT+PWM Charging with 5 Battery Modes
The controller supports 5 battery modes: Auto 12V/24V Lead-Acid, 12V Lead-Acid, 24V Lead-Acid, 12V LiFePO4, and 24V LiFePO4.

To set the battery type:

  1. From the main page, long press the "MENU" button for 3 seconds to enter the setting page.
  2. Short press "MENU" to navigate to the battery type page (labeled "USE 1" or similar).
  3. Long press "MENU" for 3 seconds to enter the battery type selection.
  4. Short press "MENU" or "SET" to switch between GEL, Sealed, Flooded, and Lithium battery types.
  5. For lithium batteries, long press "MENU" for 3 seconds on the lithium battery page to set its capacity. The parameters will flash. Use "MENU" or "SET" to adjust the capacity. Long press "MENU" for 3 seconds to save.

Battery Type Parameters Overview

Parameter USE 1 (Custom) GEL SLD (Sealed) FLD (Flooded)
Resume charge voltage13.6V13.6V13.6V13.6V
Constant voltage charge voltage14.4V14.4V14.4V14.4V
Equalization charge voltage14.6V14.2V14.6V14.8V
Absorption charge voltage14.4V14.2V14.4V14.6V
Float charge voltage13.8V13.8V13.8V13.8V
Low voltage protection voltage10.8V10.8V10.8V10.8V
Low voltage recovery voltage12.6V12.6V12.6V12.6V

For LiFePO4 and Lithium-ion batteries, specific voltage parameters are used (e.g., 4S LiFePO4, 3S Lithium-ion). These are typically pre-configured or can be customized via the 'USE 2' option.

4.3 System Voltage Setting

The controller supports 12V/24V auto-recognition. You can also manually set the system voltage.

To set the system voltage:

  1. After configuring the battery type, navigate to the system voltage setting page (labeled "AUTO" or similar).
  2. Long press the "MENU" button for 3 seconds until "AUTO" starts to flash.
  3. Short press "MENU" or "SET" to toggle between 12V or 24V.
  4. Long press "MENU" for 3 seconds to save the setting.

5. Operation

5.1 LCD Screen Overview

The LCD screen displays various system parameters and status indicators:

  • PV Array Status: Indicates day or night, and if charging is active.
  • Battery Status: Shows uncharged/battery capacity and battery type (LiPo, LiFe).
  • Load Status: Indicates if the load is on or off.
  • Numerical Displays: PV voltage, battery voltage, load current, temperature, and accumulated charging/discharging ampere-hours (AH).

5.2 Button Definitions

  • MENU Button:
    • Short Press: Switches down to the next interface.
    • Long Press (3 seconds): Enters the next interface or saves settings.
  • SET Button:
    • Short Press: Switches up or adjusts parameters.
    • Long Press (3 seconds): Exits without saving.

5.3 Load Switch On/Off

On the main display page, short pressing the "SET" button will switch the load output on or off. This function is available in any load operating mode.

5.4 Load Working Modes

The controller offers four load output modes to suit different application requirements. You can configure load output conditions and durations.

Load Working Mode options on LCD
Load Working Modes: Manual (24H), Solar Light Control (Sunset-Sunrise), Solar Light + Time Control, Reverse Light Control.
  1. LD1 (Regular Mode): The load works normally and can be turned on or off manually.
  2. LD2 (Light Control Mode): The load automatically turns on at dusk and turns off at dawn.
  3. LD3 (Light & Time Control Mode): The load turns on for a set duration after dusk and turns off at dawn. The controller automatically identifies dark and light conditions based on the local environment.
  4. LD4 (Reverse Light Control Mode): The load automatically turns on at dawn and turns off at dusk.

To configure LD3 (Light & Time Control Mode), select it, then enter the setting interface to adjust the DC output duration. The program can be activated or deactivated by selecting "on" or "off" in the switch interface.

In light control modes (LD2, LD3, LD4), the controller will start or stop the load with approximately a 30-second delay after light is detected or disappears.

5.5 Charging Duration Settings (Equalization & Absorption)

These settings optimize battery charging for specific battery types.

To set equalization or absorption charging duration:

  1. Navigate to the respective equalization or absorption charging page from the main page.
  2. Long press "MENU" for 3 seconds until the parameter starts to flash.
  3. Keep pressing "MENU" for 3 seconds to enter the duration setting page.
  4. Short press "MENU" or "SET" to increase or decrease the time.
  5. Long press "MENU" for 3 seconds to save the setting.

5.6 PV Voltage Page

To view the PV (solar panel) voltage, long press "SET" for 3 seconds to switch between the main page and the PV voltage page.

6. Maintenance

To ensure optimal performance and longevity of your solar charge controller, regular maintenance is recommended:

  • Inspect Connections: Periodically check all wiring connections for tightness and corrosion. Loose connections can cause overheating and poor performance.
  • Clean the Controller: Keep the controller clean and free from dust and debris. Ensure the heat sink fins are not obstructed to allow for proper cooling.
  • Check for Damage: Visually inspect the controller for any signs of physical damage, such as cracks, frayed wires, or discoloration.
  • Monitor Performance: Regularly check the LCD display for normal operation and any error codes.

7. Troubleshooting

7.1 Protection Functions

The controller includes several protection features to safeguard your system:

Protection Condition Status
Solar panel reversedSolar panel can be reversed if battery is not connected.Controller isn't broken.
Battery is reversedBattery can be reversed if PV is unconnected.Controller isn't broken.
Battery over-voltageBattery voltage reaches the over-voltage point.Stop charging and discharging.
Battery over-dischargeBattery voltage drops below the under-voltage point.Stop discharging.
Over-loadThe load current is over the rated current.Turn off the output.

7.2 Fault Management (Error Codes)

The controller displays error codes to indicate specific fault conditions. The fault code consists of an "E" and two digits. The first digit represents the current error count, and the second digit indicates the specific fault condition.

Error Code Cause Correction
PV array indicator off (sunlight sufficient)Solar panel is disconnected.Check if PV array connection is proper or not.
No sign on LCD (connection correct)1. Battery voltage is less than 8V.
2. Voltage of solar panel is less than battery voltage.
1. Check battery voltage (at least 8V to activate the controller).
2. The voltage of PV must be higher than battery voltage.
E1 (Ex1)Battery over discharge.The load will stop automatically and recover when battery voltage reaches 12.6V (LVR).
E2 (Ex2)Battery over voltage.Make sure the settled value of high voltage disconnection voltage is over battery voltage and reconnect PV array.
E3 (Ex3)Over load.Reduce load or check load connection.
E5 (Ex5)Controller overheating.The controller will restart after it cools down.
E6 (Ex6)Input voltage of solar panel is too high.Check voltage of solar panel and reduce quantities of solar panel in series.
E7 (Ex7)No operation.Controller will restart after setting system voltage.

8. Specifications

8.1 General Features

  • Technology: MPPT (Maximum Power Point Tracking) with PWM charging for safety.
  • Charging Efficiency: High MPPT charging efficiency of 97-99%.
  • Charging Algorithm: 3-stage charging algorithm to optimize battery performance.
  • System Voltage: 12V/24V Auto-work.
  • Battery Compatibility: AGM, Gel, Flooded, LiFePO4, Lithium-ion.
  • Max. PV Input Voltage: Up to 100V.
  • DC Output: Built-in DC output port delivers up to 30A of direct current.
  • Load Output Modes: Four configurable load output modes (Manual, Light Control, Light + Time Control, Reverse Light Control).
  • Additional Features: Dual USB ports, built-in temperature compensation, multiple protection features.
  • Smart Device: Yes, supports PC monitoring.
  • Certification: CE.

8.2 Technical Data

Parameter 20A Model 30A Model 40A Model
Rated Charge Current20A30A40A
Max. Open Voltage of PV Array<60V<75V<100V
System Rated Voltage12V/24V Auto recognized
Battery Voltage Range8V~32V
Maximum Input Power (12V)260W390W520W
Maximum Input Power (24V)520W780W1040W
Rated Discharge Current20A20A30A
Battery TypeUser default, Sealed, Flooded, GEL, LiFePO4, Li(NiCoMn)O2
Equalize Charging Voltage*Maintenance-free lead-acid: 14.6V; GEL: 14.2V; Flooded: 14.6V. Duration: 2 hours.
Absorption Charging Voltage*Maintenance-free lead-acid: 14.4V; GEL: No; Flooded: 14.8V. Duration: 2 hours.
Float Charging Voltage*Maintenance-free lead-acid, GEL, Flooded: 13.8V.
LVR (Low Voltage Recovery)*Maintenance-free lead-acid, GEL, Flooded: 12.6V.
LVD (Low Voltage Disconnection)*Maintenance-free lead-acid, GEL, Flooded: 10.8V.
Static Loss≤50mA
HVD (High Voltage Disconnection)Lead acid battery 16V
Light Control Voltage5V/10A
Temperature Compensation Coefficient-4mV/°C/2V (25°C)
Discharge Loop Voltage Drop≤0.2V
LCD Temperature-20°C ~ +70°C
Operating Temperature-20°C ~ +55°C
Storage Temperature-30°C ~ +80°C
Working Humidity≤90%, No condensation
Protection ClassIP30
Grounded TypePositive grounded
Aperture for InstallationΦ5mm

*Above parameters are for 12V system at 25°C; values are twice for 24V system.

9. User Tips

  • MPPT vs. PWM: This controller utilizes MPPT technology for primary charging, but also incorporates PWM charging for safety when the battery voltage reaches the high voltage disconnection point. This hybrid approach aims to maximize efficiency while protecting your battery.

10. Warranty and Support

For detailed warranty information and technical support, please refer to the official PowMr website or contact their support team.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.