1. Introduction
This sound level meter is designed to measure the sound level of various environments, including factories, workshops, schools, residences, offices, and traffic areas. It is also suitable for noise engineering, product quality control, and health prevention. Additionally, it can measure ambient temperature and humidity.
2. Package Contents
Please check the package for the following items:
- GVDA Digital Sound Level Meter (GD151A or GD151B)
- User Manual
- Sponge Ball (Windscreen)
- Carrying Bag

3. Device Overview
The GVDA Digital Sound Level Meter features a clear LCD display and intuitive controls. Below is an overview of the device and its display symbols.

3.1 Display Symbols
| Symbol | Description | Symbol | Description |
|---|---|---|---|
| ن | Auto Power Off | H | Data Hold |
| MAX | Maximum Value | MIN | Minimum Value |
| °C | Celsius | RH% | Humidity Unit |
| °F | Fahrenheit | Low Battery | |
| FAST | Quick Response | SLOW | Slow Response |
| dB | Decibel Unit | A | A Weighted |
| C | C Weighted |
3.2 Microphone and Sensors
The device uses a condenser microphone for sound measurement and integrated sensors for temperature and humidity.


4. Setup
4.1 Battery Installation
The device requires 3 AAA batteries (not included).
- Unscrew the battery cover on the back of the device.
- Open the battery compartment.
- Insert 3 AAA batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
- Close the battery cover and fasten the screws to secure it.
When the low battery symbol appears on the display, replace the batteries promptly.

5. Operation
5.1 General Considerations
- Wind blowing across the microphone can increase noise measurements. Use the supplied windscreen (sponge ball) when applicable.
- Calibrate the instrument before each use if possible, especially if it has not been used for a long time.
- Do not store or operate the instrument in areas of high temperature or humidity.
- Keep the meter and microphone dry.
- Avoid severe vibration.
- Remove batteries if the meter will be stored for long periods.
5.2 Basic Measurement
- Open the protection cover of the microphone.
- Press the Power button to turn on the meter.
- After power-on, the meter will display the sound pressure level reading.
- Hold the meter, facing the microphone towards the sound source to be measured.
- Read the measured value from the display.
- Press the Power button to turn off the power.
5.3 MAX/MIN Function
Press the MAX/MIN button to enable the maximum and minimum value display. Press it again to cycle through MAX and MIN values. Press and hold for about 2 seconds to return to normal measurement mode.
5.4 A/C Weighted Selection (Model B only)
For model GD151B, press and hold the A/C button for about 2 seconds to switch between A and C weighting.

5.5 Fast/Slow Time Weighted Selection
Press the F/S button to select 'FAST' (125 ms) or 'SLOW' (1 sec) time weighting. 'FAST' or 'SLOW' will appear on the display accordingly. 'FAST' response captures noise peaks and fast-emerging noise. 'SLOW' response monitors consistent sound pressure levels and averages out rapidly changing noise.

5.6 Data Hold
Press the H/* button to enable data retention. Press it again to turn off data hold and return to normal measurement.
5.7 Backlight
Press and hold the H/* button for more than 2 seconds to enable or disable the backlight.
5.8 Automatic Power Off
The meter automatically shuts down after 10 minutes of inactivity to save battery life. The Auto Power Off symbol is displayed when this function is active. To disable it, press and hold the Power button while turning on the device; release the button after power-on. The Auto Power Off symbol will disappear. Restart the instrument to restore the function.

5.9 Temperature Unit Selection
Press the °C/°F button to switch the temperature unit between Celsius (°C) and Fahrenheit (°F).
6. Maintenance
6.1 Battery Replacement
Refer to Section 4.1 for instructions on battery replacement.
6.2 Cleaning
To avoid damaging the case, do not use corrosive agents or solvents. Wipe the shell regularly with a mild detergent or a damp cloth.
7. Troubleshooting
- Device does not power on: Check battery installation and ensure batteries are fresh.
- Erratic readings: Ensure the microphone is clear of obstructions and the windscreen (sponge ball) is properly installed. Avoid strong winds or vibrations during measurement.
- Display issues: If the display is dim or incomplete, replace the batteries.
8. Specifications
| Parameter | Specification |
|---|---|
| Measurement Range | 30~130dB (GD151A: 30-130dBA; GD151B: 30-130dBA or 30-130dBC) |
| Frequency Range | 30Hz-8KHz |
| Dynamic Range | 50dB |
| Sound Accuracy | ±1.5dB (94dB@1KHz); ±5dB (94dB@8KHz) |
| Frequency Weighting | GD151A: A weighting; GD151B: A weighting, C weighting |
| Time Weighting | Fast: 125ms; Slow: 1sec |
| Temperature Range | -20°C-60°C (-4°F-140°F) |
| Temperature Accuracy | 0°C-45°C (32°F-113°F): ±1°C/2°F; Other: ±1.5°C/3°F |
| Humidity Range | 0.0%-99.9%RH |
| Humidity Accuracy | 20%-80%: ±5RH; Other: ±6RH |
| Auto Power Off | 10 minutes |
| Power Supply | 3 x AAA batteries (not included) |
| Item Size | 142 x 58 x 26mm |
| Microphone Type | Electret condenser |
| Operating Conditions | 0~50°C, <80%RH, altitude <2000m |
| Storage Conditions | -10~50°C |
9. User Tips
- This meter is excellent for comparing sound levels from different sources, such as speakers, by utilizing both A and C weighting curves (on GD151B).
- Always ensure fresh batteries are installed for accurate and consistent measurements.
- Use the sponge ball (windscreen) to minimize wind noise, especially when measuring outdoors.
10. Frequently Asked Questions (FAQ)
- Q: What brand is this sound level meter?
- A: The brand is GVDA.
- Q: Can this device notify me when a certain noise level is reached?
- A: No, this device is designed for measurement and display of sound levels, temperature, and humidity. It does not have an alarm or notification function for specific thresholds.
- Q: The display only shows up to 99.9 dB, but the description states 130 dB. Is there a switch?
- A: The device is specified to measure up to 130 dB. If your display appears to be limited to 99.9 dB, please ensure you are operating it correctly. The display may auto-range, or there might be specific conditions for displaying higher values. Refer to the full user manual for any advanced display modes or range settings.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the official GVDA website or contact your authorized retailer.