1. Introduction
The Aideepen STC-3031 is an intelligent digital soil moisture controller designed for precise humidity management in various applications. This device accurately measures soil moisture levels and controls an output based on user-defined settings, making it ideal for water-saving irrigation, greenhouses, plant cultivation, and scientific research.

2. Key Features
- Versatile Measurement: Capable of measuring various soil types with ease and speed.
- Wide Application: Suitable for water-saving irrigation, greenhouses, grass pastures, plant cultivation, and scientific cultivation.
- Precise Humidity Control: Features automatic start and stop functions for efficient soil moisture management.
- High-Quality Sensor Chip: Ensures low power consumption, high sensitivity, and stable signal transmission.
- Accurate Water Adjustment: Allows for precise control over the amount of water supplied, catering to different plant requirements.
- Ultra-Long Sensing Line: Customizable sensor line length from 1 to 20 meters for outdoor control and detection, even when immersed in water.
- Two-Channel Sensor Detection: Supports two soil moisture sensors for independent control output based on different soil moisture readings.
- Digital Display: Clear and accurate digital display for monitoring current and set humidity levels.

3. Specifications
Product Parameters:
| Parameter | Value |
|---|---|
| Product Model | STC-3031 |
| Measurement & Control Range | 0% ~ 100% |
| Resolution | 1 |
| Accuracy | ±1% |
| Relay Output Contact Capacity | 10A/240VAC |
| Sensor Type | Two soil sensors |
| Sensor Line Length | 1 meter (customizable 1-20 meters) |
| Output Power | 120W/240W/1500W (depending on model/voltage) |
| Power Supply Voltage | DC12V / DC24V / AC110-220V (optional) |
| Shell Material | Gray ABS flame retardant plastic shell |
| Power Supply (General) | 110-220VAC±10%, 50/60Hz (or DC12V/DC24V) |
Dimensions:
- Length: 75mm (2.95in)
- Width: 70mm (2.75in)
- Height: 35mm (1.37in)

4. Setup and Installation
Package Contents:
- 1x STC-3031 Soil Humidity Controller
- 2x Soil Sensor Lines (1 meter each)
Wiring Instructions:
The STC-3031 controller requires careful wiring for power, sensors, and output. There are two main wiring configurations: Independent Load Wiring and Same Negative Cutting Line Wiring.
Important Safety Note:
- Strictly distinguish the interfaces for relay, sensor, and power.
- Strictly distinguish the connection of the sensor and power.
- The sensor down-lead and power wire should be kept at a proper distance to avoid interference.
For detailed visual guidance, please refer to the wiring diagrams in the official user manual PDF available at this link.
Independent Load Wiring Diagram:
- Connect the power supply to the designated terminals.
- Connect the two soil sensors to their respective sensor input terminals.
- Connect the load (e.g., water pump, solenoid valve) to the output terminals, ensuring the load has its own independent power supply.
Same Negative Cutting Line Wiring Diagram:
- Connect the power supply to the designated terminals.
- Connect the two soil sensors to their respective sensor input terminals.
- Connect the load to the output terminals, sharing a common negative line with the controller's power supply.

5. Operating Instructions
Digital Display and Controls:
The STC-3031 features a digital display showing current ('Out') and set ('Set') humidity values. Control buttons include 'S' (Set), Up arrow, and Down arrow.

Entering Setting Mode:
To enter the setting mode for function adjustment, long press the "S" button.
Function Adjustment Codes:
| Code | Function | Setting Range | Default Value |
|---|---|---|---|
| F0 | Hysteresis Setting (Return Error) | 1 - 30 | 2 |
| F1 | Calibration Setting | -30 - 30 | 0 |
| F2 | High Humidity Alarm Setting | 0 - 100 | 100 |
| F3 | Low Humidity Alarm Setting | 0 - 100 | 0 (alarm off) |
| F4 | Delayed Start Setting | 0 - 10 | 0 Min |
Example: Setting Soil Moisture for Water Addition
Let's say you want to set the controller to start adding water when soil humidity drops to 78% and stop when it reaches 80%.
- First, long press the "S" button to enter the setting mode.
- Use the Up/Down arrows to navigate to the desired setting (e.g., the 'Set' value for target humidity).
- Set the target humidity to 80%.
- Adjust the Hysteresis Setting (F0) to 2. This means the output will turn off when humidity reaches 80% and turn back on when it drops to 78% (80% - 2%).
Note: If either of the two soil sensors reaches the set parameter, the relay will open the output.

6. Maintenance
- Sensor Care: The soil sensors are designed for corrosion resistance and can be immersed in water for long-term outdoor work. However, regular inspection for physical damage or excessive buildup is recommended. Clean sensors gently if necessary.
- Controller Unit: Keep the main controller unit clean and free from dust and moisture. The shell is made of flame-retardant ABS plastic, but it should not be exposed to extreme conditions beyond its operating specifications.
- Wiring: Periodically check all wiring connections to ensure they are secure and free from corrosion or damage.
7. Troubleshooting
This section addresses common issues you might encounter with your STC-3031 controller.
- Controller Not Powering On:
- Check the power supply connection and ensure it matches the controller's voltage requirements (DC12V, DC24V, or AC110-220V).
- Verify that the power source is active.
- Inaccurate Readings:
- Ensure sensors are properly inserted into the soil and making good contact.
- Check sensor wiring for loose connections or damage.
- Consider using the F1 Calibration Setting to adjust for any offset if you have a known reference.
- Ensure the sensor lines are kept at a proper distance from power wires to prevent interference.
- Output Not Activating/Deactivating:
- Verify that the 'Set' humidity value and 'F0 Hysteresis' settings are configured correctly for your desired operation.
- Check the wiring to the load (e.g., pump) and ensure it is correctly connected and receiving power.
- If using two sensors, remember that the relay will activate if either sensor reaches the set parameter.
- Check the F4 Delayed Start setting; if set to a non-zero value, there will be a delay before the output changes state.
- Alarm Not Functioning:
- Check F2 (High Humidity Alarm) and F3 (Low Humidity Alarm) settings. Ensure F3 is not set to 0 if you want the low humidity alarm to be active.
8. User Tips
Based on general usage and product design, here are some tips for optimizing your experience with the STC-3031:
- Sensor Placement: For best results, place sensors in representative areas of the soil you wish to monitor. For larger areas, consider using both sensors in different spots.
- Customizing Sensor Length: If the included 1-meter sensor lines are too short, remember that lines up to 20 meters can be customized for outdoor or remote applications.
- Understanding Hysteresis (F0): The hysteresis setting is crucial for preventing rapid cycling of your connected load. A value of 2 (default) means if you set the target to 80%, the output will turn off at 80% and turn back on at 78%. Adjust this value based on the sensitivity required for your plants and the response time of your irrigation system.
- Initial Calibration (F1): If you have a trusted method for measuring soil moisture, use the F1 setting to calibrate your STC-3031 for the most accurate readings in your specific soil type.
9. Warranty and Support
For warranty information, technical support, or further inquiries, please contact the seller or refer to the official product documentation. A detailed user manual in PDF format is available for download: