PowMr POW-HVM10.2M / POW-HVM6.2M

Contents

PowMr Hybrid Solar Inverter User Manual

Model: POW-HVM10.2M / POW-HVM6.2M

Brand: PowMr

PowMr MPPT Hybrid Solar Inverter

Image: PowMr MPPT Hybrid Solar Inverter, showing 10.2KW and 6.2KW models with WiFi module, 48V battery voltage, MPPT 160/120A max current, and 90-500VDC PV input voltage range.

1. Introduction

This PowMr hybrid solar inverter is a multi-function inverter/charger that combines the functionalities of an inverter, solar charger, and battery charger. It is designed to provide uninterruptible power support in a compact size. The comprehensive LCD display allows for user-configurable and easily accessible button operations, such as setting battery charging current, AC/solar charger priority, and acceptable input voltage based on various application needs.

1.1 Key Features

  • Pure sine wave output.
  • Configurable input voltage range for home appliances and personal computers via LCD settings.
  • Configurable battery charging current based on application requirements.
  • Configurable AC/Solar Charger priority via LCD settings.
  • Compatible with mains voltage or generator power input.
  • Automatic restart function when AC power recovers.
  • Built-in protections for overload, over temperature, and short circuit.
  • Smart battery charger design for optimized battery performance.
  • Cold start function for system initiation without grid power.

1.2 Basic System Architecture

The inverter integrates with solar panels, a battery bank, and can connect to either a generator or utility grid to power household loads. It is capable of powering various appliances in home or office environments, including motor-type appliances like refrigerators and air conditioners.

All-in-one Solar Charge Inverter Diagram

Image: Diagram showing the all-in-one solar charge inverter connecting PV panels, generator, and utility to a 48V battery, which then powers household loads (refrigerator, light, fan, washing machine).

1.3 Product Overview Video

Video: An unboxing and overview of the PowMr Hybrid Solar Inverter, detailing package contents and key features of the unit.

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  2. CAUTION --To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION - Only qualified personnel can install this device with battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation of this inverter/charger, please follow required specifications to select appropriate cable size. It's very important to correctly operate this inverter/charger.
  8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
  9. Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to the INSTALLATION section of this manual for details.
  10. One piece of 150A fuse is provided as over-current protection for the battery supply.
  11. GROUNDING INSTRUCTIONS - This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
  12. NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
  13. Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.

3. Package Contents

Upon unpacking, please inspect the unit and ensure nothing inside the package is damaged. You should have received the following items:

  • PowMr Hybrid Solar Inverter Unit x 1
  • User Manual x 1
  • MC4 Terminal Head x 2 pairs
  • Grounding Terminal x 1

4. Product Overview

Familiarize yourself with the inverter's components and interface:

4.1 Inverter Views

PowMr Inverter Front, Side, and Rear Views

Image: Shows the front view with LCD and indicators, a side view highlighting cooling fins, and a detailed rear view with all connection ports labeled (PV1, PV2, AC In, Main Out, Second Out, COMM, Battery).

4.2 Smart Design Features

PowMr Inverter Smart Design Features

Image: Highlights smart design features including RGB lights for different working modes (White for Stationary, Red for Battery, Blue for Utility, Purple for PV), three cooling fans for efficient heat dissipation, and an anti-dust kit for increased reliability in harsh environments.

4.3 Component Identification

  1. LCD display
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Touch Function buttons
  6. Power on/off switch
  7. AC input
  8. Main output
  9. Second output
  10. PV1 and PV2 input
  11. WIFI communication/RS-232 port
  12. Battery communication/RS-485 port
  13. Battery input
  14. Anti dust kit

5. Setup and Installation

Before connecting any lines, remove the screws under the machine and remove the bottom cover plate.

5.1 Mounting the Unit

Consider the following points when selecting where to install the inverter:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install this inverter at eye level for easy LCD display readability.
  • Allow approximately 20 cm clearance to the sides and 50 cm above and below for proper air circulation and heat dissipation.
  • The ambient temperature should be between $0^{\circ}C$ and $55^{\circ}C$ for optimal operation.
  • The recommended installation position is vertically on the wall.
  • Ensure sufficient space around the machine for adequate heat dissipation and wire management.
  • SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

Install the unit by screwing two M4 or M5 screws.

5.2 Battery Connection

CAUTION: For safety and regulation compliance, install a separate DC over-current protector or disconnect device between the battery and inverter. Refer to the table below for required fuse or breaker size.

WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for battery connection to reduce risk of injury.

Recommended Battery Cable Size
ModelWire SizeCable (mm²)Torque Value (max)
8.2KW/10.2KW1 x 2AWG252 Nm

Connection Steps:

  1. Remove 18 mm of insulation sleeve for positive and negative conductors.
  2. Use bootlace ferrules on wire ends with a proper crimping tool.
  3. Connect all battery packs as shown in the diagram below.
  4. Insert battery wires into inverter connectors, ensuring bolts are tightened to 2 Nm. Verify correct polarity.

WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.

CAUTION!! Before final DC connection, ensure positive (+) is connected to positive (+) and negative (-) to negative (-).

5.3 AC Input/Output Connection

CAUTION!! Install a separate AC breaker between the inverter and AC input power source (63A for 8.2KW/10.2KW). Do NOT mis-connect input and output connectors.

WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for AC input connection.

Recommended AC Cable Size
ModelGaugeCable (mm²)Torque Value
8.2KW/10.2KW10 AWG61.2 Nm

Connection Steps:

  1. Open DC protector or disconnector first.
  2. Remove 10mm insulation sleeve for conductors.
  3. Insert AC input wires according to polarities (Ground, Line, Neutral) and tighten terminal screws.
  4. Insert AC output wires according to polarities (Line, Neutral) and tighten terminal screws.
  5. Ensure all wires are securely connected.

WARNING: Ensure AC power source is disconnected before attempting to hardwire to the unit.

5.4 PV Connection

CAUTION: Install a separate DC circuit breaker between the inverter and PV modules.

WARNING: Use appropriate cable for PV module connection. Refer to the table below for recommended cable size.

Recommended PV Cable Size
ModelWire SizeCable (mm²)Torque Value
8.2KW/10.2KW1 x 10AWG61.2 Nm

PV Module Selection

Consider the following parameters:

  • Open circuit Voltage (Voc) of PV modules must not exceed max. PV array open circuit voltage of inverter (500Vdc).
  • Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
  • PV Array MPPT Voltage Range: 90Vdc~450Vdc.
Dual MPPT Input Diagram

Image: Diagram illustrating dual MPPT input, showing two separate strings of solar panels connected to PV1 and PV2 inputs, compatible with multiple battery types (FLD, GEL, SLD, AGM, LI).

PV Module Wire Connection: Check that the input voltage of PV array modules is within 120VDC - 500VDC. Maximum current load of each PV input connector is 10A.

CAUTION: Exceeding the maximum input voltage can destroy the unit! Check the system before wire connection.

5.5 Communication Connection

Wi-Fi Cloud Communication (Optional)

Use the supplied communication cable to connect to the inverter and Wi-Fi module. Download the APP, install it, and refer to the "Wi-Fi Plug Quick Installation Guideline" to set up the network and register. The inverter status will be displayed via the mobile phone APP or a webpage on your computer.

Battery Communication

Communication between the battery and the inverter is achieved via the battery communication interface (Baud rate: 9600). For lithium batteries, use power cables and communication cables to connect. Ensure correct positive and negative positions. The RJ45 connector of the communication cable connects to the BMS port of the inverter, and the other RJ45 connector connects to the RS485 port of the lithium battery. Ensure both inverter and battery are turned off before connecting. It is recommended to install a circuit breaker for the power cables.

6. Operation

6.1 Power ON/OFF

Once the unit is properly installed and batteries are connected, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.

6.2 Operation and Display Panel

The front panel of the inverter features an LCD display, three indicators, and four function keys. This panel provides information on operating status and input/output power.

LED Indicators

  • INV/AC (Green): Solid On for utility power, Flashing for battery/PV power.
  • CHG (Green): Solid On for fully charged battery, Flashing for charging battery.
  • FAULT (Red): Solid On for inverter fault, Flashing for warning condition.

Function Keys

  • ESC: To exit setting mode.
  • UP: To go to previous selection.
  • DOWN: To go to next selection.
  • ENTER: To confirm selection or enter setting mode.

LCD Display Icons

The LCD displays various icons for input source, configuration, fault information, output information, and battery status. These include icons for AC input, PV input, input voltage/frequency, PV voltage, charger current, battery voltage, output voltage/frequency, load percentage, and warning/fault codes.

LCD Setting Programs

Press and hold the ENTER button for 3 seconds to enter setting mode. Use UP/DOWN to select programs and ENTER to confirm. Key settings include:

  • Program 00: Exit setting mode / One-button restore setting options.
  • Program 01: Output source priority (Utility First, Solar First, SBU Priority, MKS Priority).
  • Program 02: Maximum charging current.
  • Program 03: AC input voltage range.
  • Program 05: Battery type (AGM, Flooded, User-Defined, LIB).
  • Program 09: Output frequency (50Hz/60Hz).
  • Program 10: Output voltage (220V/230V/240V).
  • Program 26: Bulk charging voltage.
  • Program 27: Floating charging voltage.
  • Program 29: Low DC cut-off voltage.
  • Program 30: Battery equalization enable/disable.
  • Program 37: GRID-tie operation mode (Off grid, Hybrid).

6.3 Operating Modes

The inverter supports various operating modes:

  • Line Mode: Inverter operates with utility power as the primary source.
  • Standby Mode: Inverter is idle, waiting for conditions to switch to an active mode.
  • Battery Mode: Inverter draws power from the battery to supply loads.
  • Grid-Tie Operation: Inverter feeds excess solar power back to the grid.

6.4 Battery Equalization

Equalization reverses the buildup of negative chemical effects like stratification and removes sulfate crystals from battery plates, which can reduce battery capacity. It is recommended to equalize batteries periodically.

To apply equalization, enable it in LCD setting program 30. You can set an equalization interval in program 35 or activate it immediately in program 36. The inverter will enter the Equalize stage when the set interval is reached or activated.

7. Maintenance

7.1 Clearance and Maintenance for Anti-Dust Kit

The inverter comes with a pre-installed anti-dust kit. This kit helps keep dust out and enhances product reliability. The inverter automatically detects the kit and adjusts internal temperature.

Maintenance Steps:

  1. Loosen the screw on the top of the inverter in a counterclockwise direction.
  2. Remove the dustproof case and take out the air filter foam.
  3. Clean the air filter foam and dustproof case.
  4. Re-assemble the dust-kit back to the inverter.

NOTICE: The anti-dust kit should be cleaned from dust every one month.

8. Troubleshooting

This section provides solutions for common issues. For persistent errors, contact customer support.

8.1 Common Problems and Solutions

Troubleshooting Guide
ProblemExplanation / Possible CauseWhat to do
Unit shuts down automatically during startupBattery voltage too low (<1.91V/Cell)1. Re-charge battery. 2. Replace battery.
No response after power on1. Battery voltage far too low (<1.4V/Cell) 2. Internal fuse tripped1. Contact repair center for fuse replacement. 2. Re-charge battery. 3. Replace battery.
Mains exist but unit works in battery modeInsufficient quality of AC power (Shore or Generator)1. Check if AC wires are too thin/long. 2. Check generator/input voltage range setting.
Buzzer beeps continuously and red LED is onOverload error / Output short circuited / Over temperature / Battery voltage too high/low / Fan faultReduce load, check wiring, ensure proper ventilation, check battery specs, replace fan.

8.2 Battery Alarm and Fault Codes

The inverter displays specific codes for battery alarms and faults:

Battery Alarm Codes (Icon Flashing)

  • 21-24: Battery Cell/Pack Over/Under Voltage
  • 25-26: Charging/Discharging Over Current
  • 27-30: Charging/Discharging Cell Over/Under Temperature
  • 34: Battery capacity too low
  • 44-45: Battery Cell Voltage/Temperature Imbalance
  • 46: Internal Communication Alarm

Battery Fault Codes (Icon Long and Bright)

  • 21-23: Battery Cell/Pack Over Voltage
  • 24-25: Battery Pack Under Voltage / Charging Over Current
  • 26-27: Discharging Over Current / Charging Cell Over Temperature
  • 28-30: Discharging Cell Over Temperature / Charging/Discharging Cell Under Temperature
  • 31-33: Ambient Over/Under Temperature / MOS Over Temperature
  • 35-37: Battery Short Circuit / Charge Overvoltage / System Failure
  • 39-43: Charging/Discharge MOS Fault / Temperature Sensor Fault / Battery Cell Fault / Sampling Communication Failure
  • 61: Communication Failure

9. Specifications

9.1 Line Mode Specifications

Parameter8.2KW10.2KW
Input Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage230Vac
Low Loss Voltage170Vac±7V (UPS); 90Vac±7V (Appliances)
High Loss Voltage280Vac±7V
Max AC Input Voltage300Vac
Nominal Input Frequency50Hz / 60Hz (Auto detection)
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time10ms typical (UPS); 20ms typical (Appliances)

9.2 Inverter Mode Specifications

Parameter8.2KW10.2KW
Rated Output Power8.2KW10.2KW
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation230Vac±5%
Peak Efficiency93%
Overload Protection3s@≥150% load; 5s@101%~150% load
Nominal DC Input Voltage48Vdc
Cold Start Voltage46.0Vdc
No Load Power Consumption70W75W

9.3 Charge Mode Specifications

Parameter8.2KW10.2KW
Charging Algorithm3-Step
AC Charging Current (Max)140Amp140Amp
Nominal PV Voltage360Vdc
PV Array MPPT Voltage Range90Vdc~450Vdc
Max. PV Array Open Circuit Voltage500Vdc
Max Charging Current (AC charger plus solar charger)160Amp

9.4 Grid-Tie Operation Specifications

Parameter8.2KW10.2KW
Nominal Output Voltage220/230/240 VAC
Feed-in Grid Voltage Range195~253VAC
Feed-in Grid Frequency Range50±1Hz/60±1Hz
Nominal Output Current35.6A44.3A
Maximum Conversion Efficiency (DC/AC)98%

9.5 General Specifications

ParameterValue
Safety CertificationCE, FCC, RoHS
Operating Temperature Range-10°C to 50°C
Storage temperature-15°C~60°C
Humidity5% to 95% Relative Humidity (Non-condensing)
Dimension (D*W*H)537*390*130mm
Weight14.5KG (8.2KW) / 14.7KG (10.2KW)

10. User Tips

  • Dual PV Inputs: This inverter features dual MPPT inputs (PV1 and PV2), allowing for two separate strings of solar panels. This is beneficial for installations with multiple roof areas or different panel orientations.
  • Certifications: The product is certified with CE, FCC, and RoHS standards, ensuring compliance with safety and environmental regulations.
  • Battery Compatibility: The inverter supports various battery types including Flooded, GEL, SLD, AGM, and Lithium (LI), offering flexibility for different energy storage solutions.

11. Warranty and Support

For technical support, warranty claims, or service inquiries, please contact the manufacturer directly.

Manufacturer Contact Information:

Company: SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD

Tel/Fax: +86 755-28219903

Email: support@powmr.com

Website: www.powmr.com

Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.