TTArtisan Light Meter II

Contents

TTArtisan Light Meter II User Manual

For DSLR and Mirrorless Cameras

1. Introduction

Thank you for purchasing the TTArtisan Light Meter II. This device is designed to provide accurate exposure measurements for your photography, compatible with a wide range of DSLR and mirrorless cameras via a cold shoe mount. Please read this manual carefully before use to ensure proper operation and to maximize the lifespan of your device.

TTArtisan Light Meter II in black and silver

Figure 1: TTArtisan Light Meter II (Black and Silver variants)

2. Specifications

FeatureSpecification
Material6061 Aluminum
Power SourceCR1632 (Light Meter II) / CR2032 (Light Meter I)
Battery LifeAround 60 hours
Measuring AngleApproximately 45°
Shutter Speed RangeAmbient 1 sec. - 1/2000 sec. (Light Meter II: 23 stops)
Measuring ModeAverage Metering
Dimensions (LWH)40mm x 35mm x 16mm
IRIS (Aperture) RangeF1.0, F1.2, F1.4, F1.7, F2.0, F2.4, F2.8, F3.5, F4.0, F5.0, F5.6, F7.1, F8.0, F10, F11, F13, F16, F19, F22
ISO Range25, 50, 100, 200, 400, 800, 1600, 3200
Comparison table of Light Meter II and Light Meter I specifications

Figure 2: Comparison of Light Meter II and Light Meter I

Diagram showing the dimensions of the Light Meter II

Figure 3: Light Meter II Dimensions (40mm x 35mm x 16mm)

3. Product Overview

Familiarize yourself with the components of your TTArtisan Light Meter II:

Diagram of Light Meter II showing indicator light and two dials

Figure 4: Indicator Light and Two Dials

  • Metering Module: The sensor that measures ambient light.
  • Indicator Light: Displays the current exposure status (over, under, accurate).
  • Indicator Point: Reference point on the dials.
  • Shutter Speed Dial: Adjusts the shutter speed setting.
  • IRIS/ISO Dial: Adjusts the aperture (f-stop) and ISO settings.
  • Metering Button: Activates the light measurement.
  • Shoe Seat: The base for mounting onto a camera's cold shoe.
  • Battery Cover: Secures the battery compartment.

4. Setup

4.1. Battery Installation

The TTArtisan Light Meter II uses a CR1632 button battery (package without battery). Follow these steps for correct installation:

  1. Open the package.
  2. Use a cross screwdriver to unscrew the top right screw at the bottom of the device (this is the battery cover).
  3. Insert the button battery. Ensure correct polarity.
  4. Important Note: When inserting the battery, first insert it from the end of the battery compartment that has the metal electrode plate. Then, gently press the other end until the battery is securely seated under the electrode metal plate to form a circuit.
  5. If you encounter difficulty, do not press violently. Adjust the battery direction and try again. Incorrect installation can damage the device.
Diagram showing correct and incorrect battery installation for the light meter

Figure 5: Correct Battery Installation. The battery must be stuck under the electrode metal plate. Pressing directly on the plate can crush it.

4.2. Cold Shoe Mount Installation

The light meter can be mounted on your camera's cold shoe. The cold shoe mount is typically attached to the bottom of the light meter using small screws. Ensure it is securely fastened. Once attached, slide the light meter into your camera's cold shoe.

Images demonstrating how to attach the cold shoe mount and position the light meter on a camera

Figure 6: Attaching the Cold Shoe Mount and various mounting positions (left, middle, right) on a camera.

5. Operating Instructions

5.1. Metering Steps

  1. Set ISO: Rotate the IRIS/ISO dial to set your desired ISO value.
  2. Aim and Measure: Aim the light meter at your subject or the scene you wish to meter. Press the metering button once. The device will take a measurement and display the exposure status via the indicator light. Wait approximately 0.5 seconds for the measurement to complete.
  3. Adjust for Accurate Exposure: Rotate either the aperture (IRIS) dial or the shutter speed dial until the indicator light turns green. A green light signifies an accurate exposure.

Example: If your ISO is set to 400, and the meter indicates F5.6 at 1/125 sec as accurate, other combinations linked by the red dotted line on the dial (e.g., F11 at 1/30 sec, F8.0 at 1/60 sec, F4.0 at 1/250 sec, F2.8 at 1/500 sec) will also yield accurate exposure.

5.2. Metering Button Function

  • Click the metering button to initiate a light measurement.
  • If there is no operation within 10 seconds after a measurement, the indicator light will automatically turn off to conserve battery. It will wake up with any subsequent operation (e.g., pressing the button again or rotating a dial).
  • If there is no operation within 60 seconds, the device will enter a deeper sleep mode. To wake it up from this mode, you must click the metering button.

5.3. Indicator Light Guide

The indicator light provides immediate feedback on your exposure status:

  • Red and Green (Overexposure within one step): Exposure is slightly over.
  • Red (Overexposure): Exposure is significantly over.
  • Green (Accurate Exposure): Exposure is correct.
  • Green and Red (Underexposure within one step): Exposure is slightly under.
  • Red (Underexposure): Exposure is significantly under.
  • No Light (Not Available): The light meter may be out of its measurable range or off.

Video 1: TTArtisan Light Meter II Product Demonstration. This video showcases the light meter's features, including accurate light measurement, 45° average metering angle, battery type, and dial ranges for IRIS, ISO, and Shutter Speed.

6. Maintenance and Care

  • Storage: If the device will not be used for an extended period, please remove the battery to prevent leakage and store the light meter in a dry place.
  • Cleaning: Use a soft, dry cloth to clean the exterior of the light meter. Do not use harsh chemicals or abrasive materials.
  • Handling: Avoid dropping the device or subjecting it to strong impacts, which can damage internal components.

7. Troubleshooting

  • Device Not Turning On: Check if the battery is installed correctly with the right polarity. Ensure the battery has sufficient charge.
  • Inaccurate Readings: Ensure the metering module is clean and unobstructed. Verify that the ISO setting on the light meter matches your camera's ISO.
  • Difficulty with Battery Removal: The battery compartment design requires careful handling. Use a small, non-metallic tool (like a plastic spudger) to gently pry the battery out if it's stuck, to avoid scratching the device.

8. User Tips

  • This light meter is compatible with standard cold shoe mounts, including those found on Pentax and Canon QL17 cameras.
  • When removing the battery, exercise caution and use appropriate tools to avoid scratching the device, as the compartment can be tight.

9. Warranty and Support

The TTArtisan Light Meter II comes with a warranty period of two years from the date of purchase. Please retain your proof of purchase (receipts, order numbers) for warranty claims.

The warranty does not cover:

  • Counterfeit products.
  • Accidental or man-made damage, including water ingress or physical impacts.
  • Damage due to improper use or unauthorized modifications.
  • Failure to provide valid proof of purchase.
  • Products where the purchase date exceeds the warranty period.

For further assistance or support, please refer to the official TTArtisan website or contact your retailer.

A detailed user manual in PDF format can be found here.

© 2024 TTArtisan. All rights reserved.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.