1. Introduction

This module is a high-precision, stable, and reliable timer relay designed for various applications, including controlling cooling fans, exhaust fans, and other devices requiring a delayed power-off function. It features adjustable time ranges and units, making it versatile for different operational needs.

2. Product Overview

Timer Relay Module Overview

Figure 1: Module Components and Indicators
This image shows the main components of the timer relay module, including the relay, adjustable potentiometer, dip switches for time range and unit selection, and indicator lights. Labels point to: "Working light: On: Long light, Delay process: blinking", "Time value adjustment", "Unit time: Lower:Seconds, Upper:Minute", and "Range value setting: Lower 0-30, Upper 0-300".

  • Working Light: Stays on when the module is powered.
  • Delay Process: The working light blinks during the active delay period.
  • Time Value Adjustment: A blue potentiometer (Time Adj) is used to fine-tune the delay duration.
  • Unit Time Selection: Red dip switches (1, 2) select between seconds (Sec) and minutes (Min).
  • Range Value Setting: Red dip switches (1, 2) select between 0-30 and 0-300 for the time range.

3. Setup and Wiring

Important: Ensure power is disconnected before performing any wiring to prevent electric shock.

Wiring Diagram for Timer Relay Module

Figure 2: Typical Wiring Diagram
This diagram illustrates how to connect the timer relay module to a 220V power supply, a heater, and a fan. It shows a switch 'K' controlling the circuit. When 'K' is closed, the heater and fan work immediately. When 'K' is broken, the heater stops immediately, and the fan stops after a set delay. Terminals L, L2, N, and FAN are clearly marked.

3.1 Terminal Descriptions

  • L: Firewire access (Live input).
  • L2: Live wire of the output side of the switch, typically connected to the live wire of the heating body or other load.
  • N: Zero line (Neutral, public).
  • FAN: Fan output, live wire (connects to the live input of the fan).

3.2 Wiring Instructions

  1. Connect the 220V AC power supply: Live to 'L', Neutral to 'N'.
  2. Connect the fan: Live input of the fan to 'FAN', Neutral input of the fan to 'N'.
  3. If using a heater or other load: Connect its live input to 'L2', and its neutral input to 'N'.
  4. Integrate a control switch (K) as shown in Figure 2 to manage the initial power state.

Note: The start button or switch controlling the module needs to be able to withstand the load current for a short duration (approx. 0.3 seconds). For example, if controlling a 5A fan, the switch should be rated for 5A or more.

4. Operating Instructions

4.1 Setting the Time Range

Time Range Setting Dip Switches

Figure 3: Time Range and Unit Selection
This image displays the red dip switches used to configure the time range and unit. It shows four configurations: 0.2s to 30s, 0.2s to 300s (5 min), 0.2s to 30 min, and 0.2s to 300 min (5 hours).

The module offers four time ranges, selected using the red dip switches (labeled '300 Min' and '30 Sec' on the module):

  • First Gear (0.2 - 30 seconds): Accuracy 0.1 seconds.
  • Second Gear (0.2 - 300 seconds / 5 minutes): Accuracy 0.3 seconds.
  • Third Gear (0.2 - 30 minutes): Accuracy 1.8 seconds.
  • Fourth Gear (0.2 - 300 minutes / 5 hours): Accuracy 18 seconds.

Refer to Figure 3 for specific dip switch configurations for each range.

4.2 Setting the Time Unit

The time unit (seconds or minutes) is also selected via the red dip switches:

  • When the selector switch is set to 'Sec' position, the unit is seconds.
  • When the selector switch is set to 'Min' position, the unit is minutes.

4.3 Adjusting the Time Value

Use the blue adjustable potentiometer (labeled 'Time Adj') to set the precise delay within the chosen range:

  • Rotate counter-clockwise (towards '-') to decrease the delay time.
  • Rotate clockwise (towards '+') to increase the delay time.

Example: Setting a 50-minute delay

  1. Set the time range to '300' (using the dip switches for 0.2 - 300 minutes).
  2. Set the time unit to 'Min' (using the dip switches).
  3. Adjust the blue potentiometer until the desired 50-minute delay is achieved. This can be done by trial and error or by using a multimeter to measure the voltage across the potentiometer (e.g., for a 30-unit range, if you want 12 units, set voltage to 2.0V if full range is 5.0V).

4.4 Operation Sequence

Operation Sequence Diagram

Figure 4: Operation Sequence Diagram
This diagram illustrates the timing relationship between the heater (L2) and the fan (FAN) output. When the heater signal goes low (turns off), the fan continues to operate for a set time 'X' before turning off, demonstrating the delay function.

The module operates by maintaining power to the fan (or other connected device) for a set duration 'X' after the primary signal (e.g., from a heater) is removed. This ensures continued operation for cooling or exhaust purposes after the main appliance has ceased operation.

5. Maintenance

The timer relay module is designed for long-term, reliable operation with minimal maintenance. To ensure optimal performance:

  • Keep the module clean and free from dust and debris.
  • Ensure it is installed in a dry environment, away from moisture and corrosive substances.
  • Periodically inspect wiring connections to ensure they are secure.
  • Avoid exposing the module to extreme temperatures or direct sunlight.

6. Troubleshooting

  • Module not powering on: Check the 220V AC power supply and ensure all input wiring (L, N) is correct and secure.
  • Load (fan/heater) not activating: Verify the wiring to the load (FAN, L2, N) and ensure the load itself is functional. Check the control switch (K) if used.
  • Incorrect delay time:
    1. Confirm the time range dip switches are set correctly for your desired duration.
    2. Confirm the time unit dip switches (Sec/Min) are set correctly.
    3. Adjust the blue potentiometer ('Time Adj') to fine-tune the delay.
  • Module behaving erratically: Disconnect power, check for any loose components or signs of damage, and re-connect power. Ensure stable power supply.

7. Specifications

Timer Relay Module Dimensions

Figure 5: Module Dimensions
This image provides the physical dimensions of the timer relay module: Length 88mm (3.5in), Width 36mm (1.42in), and Aperture 3.2mm (0.13in).

FeatureSpecification
ModelQF-RD21F
Operating VoltageAC 100V-220V
Power Consumption<1.0W (standby)
Time Range (Gear 1)0.2 - 30 seconds (Accuracy: 0.1s)
Time Range (Gear 2)0.2 - 300 seconds (5 min) (Accuracy: 0.3s)
Time Range (Gear 3)0.2 - 30 minutes (Accuracy: 1.8s)
Time Range (Gear 4)0.2 - 300 minutes (5 hours) (Accuracy: 18s)
Output VoltageSame as input voltage
Max Output Current10A
Life Span100,000 operations
Dimensions (L x W x H)88mm x 36mm x 22mm (3.5in x 1.42in x 0.87in approx.)
Screw Hole Center Distance83mm x 31mm
Screw Hole Aperture3.2mm

8. User Tips

  • This module is an excellent replacement for existing 220V bathroom fan timers that are out of order.
  • The wide range of delay values is extensive and easy to configure using the dip switches and potentiometer.
  • When integrating with a heater, carefully review the wiring diagram to ensure correct connections, especially for the 'L2' terminal.

9. Warranty and Support

For warranty information, technical support, or further assistance, please contact your original seller or refer to the product listing page. Keep your purchase records for any warranty claims.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?