1. Introduction and Features
This manual provides detailed instructions for the Gaqqee 0~60V CNC Adjustable DC Stabilized Voltage Power Supply. This versatile step-down module offers constant voltage and constant current output, making it suitable for various electronic projects and applications.
Key Features:
- High-quality, durable materials.
- Constant voltage and constant current CNC DC voltage stabilization.
- Large screen display, full-view special power LCD.
- Supports serial communication with standard MODBUS protocol.
- Complete display, simple operation, and stable performance.
2. Safety Information
Please read and understand all safety instructions before operating this device. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Ensure proper ventilation to prevent overheating.
- Do not expose the device to moisture or extreme temperatures.
- Always connect the input power correctly, observing polarity.
- Verify all connections before applying power.
- This product provides DC power supply; it is not designed for non-AC power supply (220V) directly.
- Keep out of reach of children.
3. Package Contents
Depending on the package purchased, you will receive the following components:
Package A:
- Meter head (display module) x1
- Base plate (main power module) x1
- Connection cables x2
Package B:
- Base plate (main power module) x1
4. Product Overview and Component Identification
Familiarize yourself with the main components and their functions.

- Positive input terminal (VIN+): Connect positive input voltage.
- Negative input terminal (VIN-): Connect negative input voltage.
- Positive output pole (OUT+): Connect positive load terminal.
- Negative output pole (OUT-): Connect negative load terminal.
- Power supply switch (OFF/ON): Hard switch for power on/off.
- 10K NTC external temperature sensor port: For connecting an external temperature sensor.
- Dip switch: Used to set fixed output voltages when the sole plate is used without the display for numerical control.
- Serial port communication port: For MODBUS communication.
- Display connection: Connects the main module to the display.
- Key press connection: Connects the control buttons on the display.
5. Installation
5.1. Physical Dimensions
Refer to the diagrams below for product dimensions and suggested installation opening sizes.


5.2. Wiring Connections
Connect the main power module to the display module using the provided cables. Ensure correct polarity for input and output terminals.

For serial communication, connect a TTL to 485 module or a WiFi module to the serial port communication port. This allows for multi-machine remote control via mobile app or web control.
6. Initial Setup: Fixed Voltage Output (DIP Switch)
The DIP switch on the main board allows for setting fixed output voltages. This is particularly useful when using the module without the dedicated display for numerical control.

Refer to the truth table on the back of the baseboard (and Figure 6.1) to configure the DIP switches for desired fixed output voltages (5V, 9V, 12V, 24V, 36V, 48V, 60V). The "NC" setting indicates numerical control gear, which must be set when using the dial head numerical control to adjust pressure.
7. Operating Instructions
7.1. Setting Voltage and Current

- In the operation interface, press the V/A button to enter the setting voltage and current interface.
- The LCD downlink will display "SET", and "CV" will flash.
- Press the SW button or rotate the encoder to switch voltage selection and adjust the set voltage.
- Press the V/A button again. The LCD downlink will display "CC" flashing.
- Press the SW button or rotate the encoder to switch current bit selection and adjust the set current.
- Press the V/A button again to exit and save settings, returning to the operating interface.
- Long press the V/A button for 2 seconds, or wait for 6 seconds without any key operation, and the system will automatically exit and save settings.
7.2. Quick Setting of Voltage or Current

In the parameter setting interface, set the parameter "FET" to "CV" (Constant Voltage) or "CC" (Constant Current). Rotate the encoder in the operation interface, then enter the setting voltage and current interface, and use the rotary encoder to quickly set the voltage or current.
7.3. Parameter Setting Interface

- On the running screen, hold down SW for 2 seconds to enter the parameter setting screen.
- Press SW to switch between parameters. Press the encoder button to switch bit selection, rotate the encoder to adjust values.
- For Maximum Capacity (OAH), Maximum Power (OPH), or Maximum Running Time (OHP), press the "ON/OFF" button to enable/disable. If disabled, "----" will be displayed.
- On the OAH/OPH screen, hold down "ON/OFF" to select capacity range (e.g., 9.999Ah, 99.999AH, etc.).
- After setting, hold down SW for 2 seconds to exit. Settings are automatically saved.
7.4. Input and Output Voltage Display

Press the SW button on the running interface to switch between displaying input and output voltage.
7.5. View Power, Capacity, Energy, and Time

In the operation interface, press the encoder button to switch the display between power (W), capacity (Ah), energy (Wh), and time (h).
7.6. Locking Function

In the operation interface, long press the encoder button for 2 seconds to lock the voltage and current settings, preventing misoperation. After locking, a lock symbol will be displayed. To unlock, long press the encoder button for 2 seconds again.
7.7. Data Group Function

This product has 10 sets of data (Cd0 to Cd9). Data is saved in Cd0 by default. Note that Cd8=12V and Cd=24V cannot be adjusted.
- Long press the V/A key for 2 seconds to enter the data group call-out interface. The upper two lines display the set voltage (CV) and current (CC) of the data group. The downstream display shows the data group number (CD1-CD9).
- Press the V/A key to switch between setting voltage (CV), setting current (CC), and data set serial number (Cd). Modify parameter values using the encoder.
- After confirming the data group, long press V/A to exit the data group and return to the operation interface.
7.8. Capacity/Energy/Running Time Statistics and Protection
- Statistics: When powered ON, statistics automatically start. When powered OFF, the previous state's value is displayed. When powered ON again, the record restarts. To clear data, press and hold ON/OFF for 2 seconds on the corresponding screen.
- Maximum Capacity (OAH)/Energy (OPH): If enabled, the power supply automatically shuts down output and flashes "OAH"/"OPH" if statistical capacity/energy exceeds the set maximum. Clearing the alarm clears statistics.
- Maximum Discharge Time (OHP): If enabled, the power output automatically turns off and "OHP" blinks if running time exceeds the set maximum. Clearing the alarm clears time statistics.
- Note: If OAH/OPH and OHP are not enabled, the power supply records capacity/energy and running time. If enabled, it shuts down output upon reaching the set value. If OHP is enabled, running time is in countdown mode.
8. Specifications
| Parameter | Value (XY6015L) | Value (XY6020L) |
|---|---|---|
| Input Voltage | 6.0~70V | 6.0~70V |
| Output Voltage | 0.0~60V | 0.0~60V |
| Input Current | 0~15.00A | 0~20.00A |
| Output Power | 0~900W | 0~1200W |
| Output Ripple Typical Value | 100mv VPP | 100mv VPP |
| Maximum Output Voltage | (Input voltage + 1.1)-2 | (Input voltage + 1.1)-2 |
| Voltage Resolution | 0.01V | 0.01V |
| Current Resolution | 0.01A | 0.01A |
| Input Voltage Accuracy | ±1% + 5 words | ±1% + 5 words |
| Output Voltage Accuracy | ±0.4% + 1 word | ±0.4% + 1 word |
| Output Current Accuracy | ±0.5% + 3 words | ±0.5% + 3 words |
| Cooling Fan ON (Conditions) | Current >2A, Power >50W, Temp >50℃ | Current >2A, Power >50W, Temp >50℃ |
| Cooling Fan OFF (Conditions) | Current <1.5A, Power <45W, Temp <45℃ | Current <1.5A, Power <45W, Temp <45℃ |
Protection Mechanisms:
| Protection Type | Setting / Default |
|---|---|
| External Temperature Protection | 0-110°C (Default OFF) |
| Input Overvoltage Protection | 71V (Default) |
| Input Undervoltage Protection | 4.8-71V Adjustable (Default 4.8V) |
| Output Overvoltage Protection | 0-65V Adjustable (Default 65V) |
| Output Overcurrent Protection (XY6015L) | 0-16A Adjustable (Default 16A) |
| Output Overcurrent Protection (XY6020L) | 0-22A Adjustable (Default 22A) |
| Output Over Power Protection (XY6015L) | 0-950W Adjustable (Default 950W) |
| Output Over Power Protection (XY6020L) | 0-1250W Adjustable (Default 1250W) |
| Over Temperature Protection | 60-110°C (Default 95°C) |
| Timeout Protection | 0-100H Adjustable (Default OFF) |
| Over Capacity Protection | 0~9999AH Adjustable (Default OFF) |
| Super Energy Protection | 0~9999WH Adjustable (Default OFF) |
9. Troubleshooting
- No output voltage/current:
- Ensure all input and output connections are secure and correctly polarized.
- Check if the power supply switch is in the "ON" position.
- Verify that the input voltage is within the specified range (6.0~70V) and is higher than the desired output voltage, as this is a step-down module.
- Check for any active protection mechanisms (e.g., OVP, OCP, OPP, OTP) that might have shut down the output.
- Display not working or showing incorrect values:
- Ensure the display module is correctly connected to the main board via the display connection cable.
- If you purchased a module without a display, you will need to acquire a compatible display unit separately for full functionality.
- Output voltage fixed despite display settings:
- Check the DIP switch settings on the main board. If fixed voltage settings are enabled via the DIP switch, the display's numerical control might be overridden. Set the DIP switch to "NC" (numerical control gear) if you intend to use the display for adjustable voltage.
10. User Tips
- Display Compatibility: If you purchased a base plate only, you will need a compatible display module to access the full range of adjustable settings and monitoring features. Ensure any separately purchased display is designed for this model.
- Step-Down Functionality: Remember that this is a step-down module. The input voltage must always be higher than the desired output voltage for proper operation.
- Soldering Applications: While this power supply can provide stable voltage and current for powering a soldering iron, it is not a soldering machine itself. Ensure your soldering iron's power requirements match the module's output capabilities.
11. Maintenance
- Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
- Ensure adequate airflow around the module, especially the heat sink and fan, to prevent overheating.
- Avoid dropping or subjecting the device to strong impacts.
- Store in a dry environment when not in use.
12. Product Demonstration Video
13. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the seller's policies or contact the retailer where the product was purchased. Keep your purchase receipt as proof of purchase.
A user manual in PDF format is available for download: User Manual (PDF)