The Hi-Link 5W Ultra-small Series AC DC Power Supply Module is a compact, high-efficiency power solution designed for a wide range of applications. It features a global input voltage range, low temperature rise, low power consumption, high efficiency, high reliability, and high safety isolation. This module is suitable for use in smart home devices, automation control systems, communications equipment, and various instrumentation.

This manual provides essential information for the safe and effective use of your Hi-Link power supply module.

2. Product Features

  • Ultra-thin, ultra-small, smallest volume design.
  • Global universal input voltage range: 85~265Vac.
  • Low power consumption with green environmental protection; no-load loss is less than 0.1W.
  • Features low ripple and low noise output.
  • Equipped with high output short circuit and over-current protection with self-recovery capabilities.
  • High efficiency and high power density.
  • Input and output isolation voltage of 3000Vac.
  • 100% full load aging and testing ensures reliability.
  • High reliability and long life design, with a continuous working time greater than 100,000 hours.
  • Meets UL and CE requirements; product design adheres to EMC and safety testing standards.
  • Utilizes high-quality, environmentally friendly waterproof plastic potting, providing moisture, vibration, water, and dust resistance to meet IP65 standards.
  • Economic and cost-effective solution.
  • Operates without the need for external circuitry.
  • Comes with a 1-year quality guarantee period.

3. Specifications

3.1. Environmental Conditions

Item Parameter
Working Temperature-25°C to +60°C
Storage Temperature-40°C to +80°C
Relative Humidity5-95%
Thermal MethodsNatural cooling
Atmospheric Pressure80-106 Kpa
Altitude<2000m
Vibration10~500Hz, 2G10min./1cycle, 60min.each along X,Y,Z axes (Meets requirements for secondary road transportation)

3.2. Electrical Characteristics (Input)

Item Parameter Units Notes
Rated Input Voltage100~240Vac
Input Voltage Range85-265VacOr 70-350Vdc
Maximum Input Current≤0.2A
Input Inrush Current≤10A
Input Low Start≤50mS
Long-term Reliability (MTBF)≥100,000h
External Fuse Recommended1A / 250Vac or 10Ω wire wound resistanceSlow blow

3.3. Electrical Characteristics (Output)

Model Output Voltage (Vdc) Output Current (mA) Output Ripple & Noise (mVp-p)
HLK-5M033.3 ±0.1 (No-load), 3.3 ±0.2 (Full-load)1500 (Long-time), ≥1800 (Short-time max)≤100
HLK-5M055.0 ±0.1 (No-load), 5.0 ±0.2 (Full-load)1000 (Long-time), ≥1200 (Short-time max)≤100
HLK-5M099.0 ±0.1 (No-load), 9.0 ±0.2 (Full-load)560 (Long-time), ≥680 (Short-time max)≤120
HLK-5M1212.0 ±0.1 (No-load), 12.0 ±0.2 (Full-load)450 (Long-time), ≥540 (Short-time max)≤120
HLK-5M1515.0 ±0.1 (No-load), 15.0 ±0.2 (Full-load)333 (Long-time), ≥440 (Short-time max)≤120
HLK-5M2424.0 ±0.1 (No-load), 24.0 ±0.2 (Full-load)208 (Long-time), ≥308 (Short-time max)≤150

Note: Output ripple and noise are measured at rated input voltage, full output load, with a 20MHz bandwidth oscilloscope, and a load side test with 10uF and 0.1uF capacitors.

  • Voltage Regulation: ±0.2%
  • Load Regulation: ±0.5%
  • Input Low Voltage Efficiency (Vin=115Vac, Output full load): ≥69%
  • Input High Voltage Efficiency (Vin=230Vac, Output full load): ≥70%
  • Switching On/Off Overshoot Amplitude: (Rated input voltage, output plus 10% load) ≤5%Vo
  • Output Over-Current Protection: Output maximum load 110-150%
  • Output Short Circuit Protection: Direct short circuit in normal output and automatic return to normal operation after removal of short circuit (No damage to the whole device).

3.4. Dimensions and Weight

  • Module Dimensions (L x W x H): 38 x 23 x 18 mm
  • Module Weight: 32 ± 1g
  • Package Dimensions (L x W x H): 15 x 9 x 3 cm
  • Package Weight: 0.05 kg
Dimensional drawing of the Hi-Link 5W power module
Dimensional drawing of the Hi-Link 5W power module, showing measurements in millimeters and pin layout.

4. Setup and Installation

4.1. Pin Function

Pin Function
1AC Input
2AC Input
3-Vo (Negative Output Voltage)
4+Vo (Positive Output Voltage)

Pin length error: ±1mm. Pin diameter error: -0.2mm.

For optimal performance and safety, it is recommended to use the following external components in conjunction with the power module. The typical application circuit involves connecting the AC input (L and N) through a fuse and varistor, followed by a safety capacitance and common-mode inductance before reaching the power module's AC input pins. The output (+Vo and -Vo) should be connected to the load (RL) with a filter capacitor (C2) in parallel.

Table of electrical characteristics for the power module
Table showing various electrical characteristics and parameters of the power module.
  • F1/Fuse: 1A / 250Vac or 10Ω wire wound resistor (Slow blow type recommended). This protects the circuit from damage if the module malfunctions.
  • MOV1/Varistor: 10D561K. This protects the module from cumulative surges.
  • C1/Safety Capacitance: 0.1uF / 275Vac. Essential for filtering and EMC certification.
  • L1/Common-mode Inductance: Sensible value 10-30mH (Testing requirements: 1KHZ / 0.3V current: 100-500mA). Used for EMI filtering.

Note: Fuse and varistor are basic protective circuits and must be connected. If authentication/certification is required, the safety capacitance and common-mode inductance cannot be omitted.

  • C2/Filter Capacitor: Aluminium electrolytic capacitance, capacity 100-220uF, with a voltage reduction greater than 75%. Adding this capacitor can reduce the output ripple from the original 50mV to 30mV.

5. Operating Instructions

  1. Connect Input: Connect the AC input (L and N) to your power source (100-240Vac, 50-60Hz) ensuring proper safety components (fuse, varistor, capacitors, inductors) are in place as per the recommended circuit.
  2. Connect Output: Connect the +Vo and -Vo pins to your load. Ensure correct polarity to prevent damage to the load or the module.
  3. Power On: Apply power to the AC input. The module will automatically regulate the output voltage to the specified level.
  4. Monitor Performance: Observe the load's operation. The module is designed for stable output under various load conditions within its specified limits.
  5. Overload/Short Circuit: In case of an overload or short circuit, the module's protection features will activate, and it will automatically recover once the fault condition is removed.
Video demonstrating the physical appearance and handling of the Hi-Link 5W power module.

6. Maintenance

  • Keep Clean: Ensure the module is free from dust and debris to maintain proper heat dissipation.
  • Environmental Control: Operate and store the module within the specified temperature and humidity ranges.
  • Avoid Physical Stress: Do not subject the module to violent vibration, impact, or excessive mechanical stress.
  • Regular Inspection: Periodically check connections for tightness and signs of wear or corrosion.
  • No User-Serviceable Parts: The module itself contains no user-serviceable parts. Do not attempt to open or repair the module, as this may void the warranty and pose a safety risk.

7. Troubleshooting

  • No Output Voltage:
    • Check if the input AC voltage is within the specified range (85-265Vac).
    • Verify all input and output connections are secure and correctly polarized.
    • Inspect the external fuse (if used) for continuity.
    • Ensure the load is not drawing excessive current, which might trigger over-current protection.
  • Unstable Output Voltage / High Ripple:
    • Confirm that the recommended external filter capacitor (C2) is correctly installed and has the appropriate specifications.
    • Check for any loose connections or interference in the circuit.
    • Ensure the load is not fluctuating rapidly or exceeding the module's capacity.
  • Module Overheating:
    • Verify that the ambient operating temperature is within the specified range (-25°C to +60°C).
    • Ensure adequate natural cooling is provided and the module is not enclosed in a way that restricts airflow.
    • Check if the load current is consistently at or above the maximum long-time output current.

If issues persist after checking these points, consult the official documentation or contact technical support.

8. User Tips

  • Verify Specifications: Always double-check the specific output voltage and current requirements of your application against the module's specifications (e.g., HLK-5M03 for 3.3V, HLK-5M12 for 12V) to ensure compatibility and prevent damage.
  • Proper Grounding: While not explicitly detailed in the basic diagram, ensuring proper grounding practices in your overall circuit design can enhance stability and reduce noise.
  • Consider a Heatsink for High Loads: Although designed for natural cooling, for continuous operation at the upper limits of its load capacity, especially in warmer environments, consider providing additional passive cooling or ensuring ample air circulation.

9. Safety and Certifications

The Hi-Link 5W power module is designed to meet stringent safety and electromagnetic compatibility (EMC) standards. Users are responsible for ensuring their final product design complies with relevant certifications based on the module's reference circuit.

9.1. Certifications

  • Product design meets UL and CE safety certification requirements.
  • Safety Standard Compliance: UL1012, EN60950, UL60950.
  • Insulation Voltage (Input/Output): 2500Vac.
  • Insulation Resistance (Input/Output): >100M Ohms / 500Vdc at 25°C, 70% RH.

9.2. Electromagnetic Compatibility (EMC)

  • Conduction and Radiation: Meets EN55011, EN55022 (CISPR22).
  • Electrostatic Discharge (ESD): IEC/EN 61000-4-2 level 4 (8kV/15kV).
  • Radio Frequency Radiation Immunity: IEC/EN 61000-4-3.

9.3. Material and Construction Safety

  • Input design incorporates a UL listed 1A/250Vac slow-blow fuse or 10Ω wire-wound resistor.
  • The PCB board is made of double-sided copper clad foil, with a material fire resistance grade of 94-V0.

10. Marking, Packaging, Transportation, and Storage

10.1. Product Marking

Each product features a unique barcode for traceability, including the date of manufacture and product batch. The marking content complies with national and industry standards.

10.2. Packaging Marking

Product boxes are marked with the manufacturer's name, site, zip code, product model, and manufacturing date (factory year, month, day). Transport signs such as "up", "moisture-proof", and "carefree" are included, all in line with GB 191 provisions.

10.3. Packaging

Products are packaged in special plastic boxes with anti-vibration functionality, conforming to GB 3873 standards.

10.4. Transportation

Packaged products can be transported by any means. During transit, they should be protected by an awning and must not be subjected to violent vibration, impact, or other damaging forces.

10.5. Storage

Product storage must adhere to the requirements specified in GB3873.

11. Warranty and Support

This Hi-Link power supply module comes with a 1-year quality guarantee period from the date of purchase.

For technical support or warranty claims, please refer to the official Hi-Link website or contact your distributor. When contacting support, please provide your product model (e.g., HLK-5M12) and a detailed description of the issue.

For the most comprehensive and up-to-date information, please refer to the official user manual PDF: Hi-Link 5W Power Module User Manual (PDF).

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.