1. Introduction
Thank you for choosing the PowMr HHJ-60A MPPT Solar Charge Controller. This manual provides essential information for the safe and efficient operation of your solar charging system. The HHJ-60A is a powerful MPPT solution with a 60A charging current, designed for optimal performance in various solar setups.
This controller features a high-performance DSP controller for fast digital signal processing, ensuring 99.9% tracking efficiency. It supports a wide range of system voltages (12V, 24V, 36V, 48V) and is compatible with multiple battery types, including sealed lead-acid, flooded, gel, and lithium batteries.
Video: PowMr HHJ-60A MPPT Solar Charge Controller Overview
2. Important Safety Instructions
Please read and save these instructions. This manual contains important safety, installation, and operating instructions for the charge controller. The following symbols are used to indicate potentially dangerous conditions or important safety information:
- WARNING: Indicates a potentially dangerous condition. Use extreme caution when performing this task.
- CAUTION: Indicates a critical procedure for safe and proper operation of the controller.
- NOTE: Indicates a procedure or function that is important to the safe and proper operation of the controller.
2.1 General Safety Information
- Read all instructions and cautions in the manual before beginning installation.
- There are no serviceable parts for this controller. DO NOT disassemble or attempt to repair the controller.
- DO NOT allow water to enter the controller.
- Make sure all connections going into and from the controller are tight.
2.2 Charge Controller Safety
- NEVER connect the solar panel array to the controller without a battery. The battery must be connected first.
- Ensure input voltage does not exceed 160 VDC to prevent permanent damage. Use the Open Circuit Voltage (Voc) to make sure the voltage does not exceed this value when connecting panels together.
2.3 Battery Safety
- Use only sealed lead-acid, flooded, gel, or lithium batteries which must be deep cycle.
- Explosive battery gases may be present while charging. Be certain there is enough ventilation to release the gases.
- Be careful when working with large lead-acid batteries. Wear eye protection and have fresh water available in case there is contact with battery acid.
- Carefully read battery manuals before operation.
- DO NOT let the positive (+) and negative (-) terminals of the battery touch each other. Recycle battery when it is replaced.
- Over-charging and excessive gas precipitation may damage the battery plates and activate material shedding on them. Too high of an equalizing charge or too long of one may cause damage. Please carefully review the specific requirements of the battery used in the system.
- Equalization is carried out only for non-sealed / vented / flooded / wet cell lead-acid batteries.
- DO NOT equalize VRLA type AGM / Gel / Lithium cell batteries UNLESS permitted by the battery manufacturer.
3. Setup and Installation
Proper installation is crucial for the performance and longevity of your solar charge controller. Follow these steps carefully:
3.1 Dimensions
The physical dimensions of the controller are approximately 214mm x 115mm x 50mm (8.43in x 4.53in x 1.97in).
Image: PowMr MPPT Solar Charge Controller with dimensions and fan cooling details.
3.2 Connection Steps
- Connect the batteries (1st step): Connect the battery connection cable with the correct polarity to the middle pair of terminals on the solar charge controller (marked with the battery symbol). If the system is 12V, ensure your battery voltage is more than 12V for the controller to boot up.
- Connect the solar panel (2nd step): Ensure that the PV modules are protected from incident light and that the solar panel voltage does not exceed the maximum permissible input current. Connect the PV modules connection cable to the correct polarity of the left pair of terminals on the solar charge controller (marked with the PV modules symbol).
- Connect loads (3rd step): Connect the load cable to the correct polarity of the right pair of terminals on the solar charge controller (marked with the lamp symbol). To avoid any voltage on the wires, connect the wire to the load before connecting to the controller.
- Final check (4th step): Tighten all cables connected to the controller and remove all debris around the controller, leaving a space of approximately 5.91 inches for ventilation.
Image: Wiring diagram for the solar charge controller.
3.3 Air Circuit Breaker Installation
We strongly recommend connecting a fuse directly to the battery to protect against any short circuit at the battery wiring. Solar PV modules create current whenever light strikes them. The current created varies with light intensity, but even with low light, full voltage is present. Protect the solar modules from incident light during installation. Never touch uninsulated cable ends, use only insulated tools, and ensure the wire diameter is in accordance with the expected currents of the solar charge controller. Connections must always be made in the sequence described below.
It's better to connect two wires to two PV+ and another two wires to two PV-. For BAT+ and BAT-, it's the same way to connect wires.
- Install an air circuit breaker between the controller and batteries. Turn off the circuit breaker, then connect batteries to the controller with correct polarity.
- Install an air circuit breaker between the controller and PV modules. Turn off the circuit breaker, and ensure the PV polarity is correct, then connect wires between PV modules and the controller.
- Turn on the air circuit breaker between the controller and batteries.
- Turn on the air circuit breaker between the controller and PV modules.
- The controller goes into self-test mode. Its LCD displays parameters if all is correct. The RUN lamp (under the fan inside the casing) will flash every one second. If the controller is unresponsive, please read the full manual again for reinstalling or contact us for help.
Air Circuit Breaker and Wires Requirement
| Models | Copper wires | Air circuit breakers |
|---|---|---|
| MPPT-60A | 6mm²x2PCS | 100A |
4. Operation
The controller features an intuitive LCD display for monitoring and configuration.
4.1 Main Interface LCD Display
The main interface displays key operational parameters:
- PV: PV voltage / Output power
- OUTPUT: Working mode / Temperature
- BATT: Battery voltage / Charging current
- Protection mode: Indicates active protection status.
Image: Detailed view of the LCD display and its indicators.
4.2 Working Modes
The controller operates in several distinct modes to optimize battery charging:
- 3.0 Night Mode: No charging occurs.
- 4.0 MPPT Mode: Maximum Power Point Tracking for efficient solar energy conversion.
- 7.0 Absorption Mode: Charges the battery to its full capacity at a constant voltage.
- 8.0 Floating Mode: Maintains the battery at a full state of charge by providing a constant, low voltage.
Image: Illustration of the 3-stage charging process.
5. Manual Settings
The controller will work fine under default settings, except for lithium batteries, which may require specific adjustments.
5.1 Battery Charge Voltage Reference
| Battery Type | Absorption Voltage (Constant voltage) | Floating Voltage | ||||
|---|---|---|---|---|---|---|
| 12V | 24V | 48V | 12V | 24V | 48V | |
| Vented | 14.2V | 28.6V | 57.2V | 13.2V | 26.4V | 52.80V |
| Sealed | 14.4V | 28.8V | 57.6V | 13.8V | 27.6V | 55.2V |
| Gel | 14.4V | 28.8V | 57.6V | 13.8V | 27.6V | 55.2V |
| NiCd | 14.2V | 28.6V | 57.2V | 14.0V | 28.0V | 56.0V |
| Lithium or others | Defined by users | |||||
5.2 Setting Procedures
Use the PRG, ENT, UP, and DOWN buttons on the controller to navigate and adjust settings.
-
Step 1: D00 (Load Working Time)
Press the PRG button until the LCD displays D00. This is for setting the load working time (default is 24 hours). Press ENT until numbers flash, then use UP/DOWN to set the desired time. Long-press ENT to confirm. This output voltage is the same as the battery. The load is only for small DC loads less than 5A current. If no load, leave it. -
Step 2: D01 (Floating Charging Voltage)
Press the UP button. The LCD shows 13.8 (default value for floating charging). Press ENT until numbers flash, then use UP/DOWN to set the desired voltage. Long-press ENT to confirm.CAUTION: This value is for one 12V battery. If there are many batteries in series, the controller will multiply them in proportion automatically, and the LCD only displays the voltage of one battery (e.g., for a 4x12V battery, if you set 14.1V, the charge voltage will be 4x14.1V automatically, but the LCD only displays 14.1V). -
Step 3: D02 (Absorption Charging Voltage)
Continue to press the UP button. The LCD shows 14.5 (highest absorption charging voltage for battery). Press ENT until numbers flash, then use UP/DOWN to set the desired voltage. Long-press ENT to confirm.CAUTION: This value is for one 12V battery. If there are many batteries in series, the controller will multiply them in proportion automatically, and the LCD only displays the voltage of one battery. -
Step 4: D03 (Battery Discharge Protection Voltage)
Continue to press the UP button. The LCD shows 10.0. This is the protection value for battery discharge. Press ENT until numbers flash, then use UP/DOWN to set the desired voltage. Long-press ENT to confirm. This means it's protected when a 12V battery is less than 10.0V, and there will be no output power from OU+ and OU-. -
Step 5: D04 (Battery Type Selection)
Continue to press the UP button. The LCD shows 00.00, which is the default for acid batteries. If using a lithium battery, press ENT until numbers flash, then use UP/DOWN to choose 01. Long-press ENT to confirm. Note that Step 2 (D01) is not used when you choose 01 for lithium battery. The voltage set in Step 3 (D02) will be the highest charging voltage for the lithium battery.
Press ESC to exit the setting menu.
6. Troubleshooting
The controller includes a fault diagnosis system to help identify and resolve issues quickly.
| Code | Description | How to solve |
|---|---|---|
| 18 | Input PV voltage is low | Increase the PV voltage |
| 60 | Over-temperature protection | Fan will work and temperature reduction automatically |
| 63 | Battery voltage is high | Battery high voltage protection and wait for recovery |
| 65 | Battery voltage is low | Battery over-discharge and wait for recovery |
| 71 | Input PV voltage is high | Decrease the PV voltage |
| 73 | Over-charging current | Decrease the PV power |
7. Protections
The PowMr HHJ-60A MPPT Solar Charge Controller incorporates several built-in protection features to ensure the safety and longevity of your system:
- PV Over Current: The controller will limit charging power to its rated charge power. An over-sized PV array will not operate at maximum power point.
- PV Short Circuit: When a PV short circuit occurs, the controller will stop charging. Remove the short circuit to resume normal operation.
- PV Reverse Polarity: Full protection against PV reverse polarity is provided, causing no damage to the controller. Correct the connection to start normal operation.
- Battery Over Voltage: If other energy sources charge the battery, and the battery voltage exceeds 15.5V (for 12V system, scaled for 24V/36V/48V), the controller will stop charging to protect the battery from overcharging damage.
- Battery Over Discharge: When battery voltage drops to the set low voltage disconnect point, the controller will stop discharging to protect the battery from over-discharging damage.
- Load Over Current Protection: If the load current exceeds 1.25 times the maximum load current rating, the controller will disconnect the load.
- Load Short Circuit Protection: Once a load short circuit happens, the load short circuit protection will activate automatically.
- Over Temperature Protection: The internal fan will activate to reduce temperature automatically if the controller's temperature exceeds safe limits.
8. Specifications
| Feature | Value | |
|---|---|---|
| Model | MPPT-60A | |
| Charging mode | 3-stage: constant current (MPPT), 4-constant voltage, Floating | |
| Max. PV Input Power | 12V system | 720W |
| 24V system | 1440W | |
| 36V system | 2100W | |
| 48V system | 2800W | |
| Input specification DC | 12V system DC | 20V~80V |
| 24V system DC | 37V~105V | |
| 36V system DC | 50V~160V | |
| 48V system DC | 72V~160V | |
| Battery voltage automatic recognition | 12V Battery | DC9V~DC15V |
| 24V Battery | DC18V~DC29V | |
| 36V Battery | DC30V~DC39V | |
| 48V Battery | DC40V~DC60V | |
| Overcharging protection voltage | 60V | |
| Limited current protection | 61A | |
| Max efficiency | ≥98.1% | |
| PV utilization | ≥99% | |
| Protection Function | ||
| Temperature protection | 75°C / 167°F | |
| Fan-on temperature | >45°C / 104°F | |
| Fan-off temperature | <40°C / 95°F | |
| Properties | ||
| Size (mm)/(in) | 214x115x50mm / 8.43x4.53x1.97in | |
| Net weight (Kg)/(lb) | 1.1 / 2.43 | |
| Gross weight (Kg)/(lb) | 1.2 / 2.65 | |
| Electromagnetic compatibility | Accord to EN61000, EN55022, EN55024 | |
| Enclosure | IP21 | |
| Environmental temperature | -20°C ~ +55°C | |
| Storage temperature | -40°C ~ +75°C | |
9. User Tips
- Lithium Battery Compatibility: The controller is compatible with lithium batteries. Remember to adjust the battery type setting (D04) to '01' for lithium batteries, as the default is for acid batteries. The absorption charging voltage (D02) will then serve as the highest charging voltage for lithium batteries.
- Voltage Range: The controller supports a wide system voltage range (12V/24V/36V/48V), making it suitable for most setups.
- Troubleshooting: If you encounter issues, refer to the troubleshooting section for error codes and solutions. For persistent problems, especially if your PV input power or voltage seems insufficient, contact customer support.
10. Warranty and Support
10.1 Warranty Regulations
- Within 30 days from the date of purchase, a faulty controller will be replaced free of charge under normal usage (with authorization from the company's technical personnel).
- Within 2 years from the date of purchase, a faulty controller will be repaired free of charge.
10.2 Contact Information
For any questions or support, please contact:
- Email: support@powmr.com
- Web: www.powmr.com
- Phone/Fax: +86 755-28219903
- Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China
A PDF version of this user manual is available for download: PowMr MPPT Solar Charge Controller User Manual (PDF)
11. Content Included
The product package typically includes:
- 1x MPPT Solar Charge Controller
- 4x Corner connections
- 4x Screws for controller casing
- 1x English manual