1. Introduction
The Ziqqucu JY-S65 is a versatile Load Cell Sensor Transmitter Amplifier Module designed for signal amplification, conditioning, and transmission. It converts low-level sensor signals into standard voltage or current outputs, making it suitable for various industrial applications involving weighing, tension, pressure, and torque sensors. This module operates on a DC12-24V power supply and offers high accuracy and reliable performance with adjustable zero and full-scale outputs.
For a comprehensive guide, please refer to the official user manual PDF available at: JY-S65 User Manual (PDF)

Figure 1: JY-S65 Module with key features highlighted. It shows the module with green terminal blocks on both sides, indicating a 12-24V power supply, high accuracy, reliable performance, zero/full scale adjustability, and output options of 0-5V, 0-10V, 4-20mA, with a true 0V output.
2. Setup
2.1 Unpacking
Verify that the package contains the following item:
- JY-S65 Load Cell Sensor Transmitter Amplifier Module (x1)
2.2 Power Supply
The module requires a DC12-24V power supply. Ensure the power supply is stable and within the specified voltage range to prevent damage to the module.
2.3 Wiring Connections
The JY-S65 module is equipped with plug-in terminal blocks for easy connection. The left 4 terminals are for sensor input, and the right 5 terminals are for power supply and output signals. Refer to the wiring diagram and interface definition table below for correct connections.

Figure 2: Wiring Diagram. This diagram illustrates connecting a load cell sensor to the module's input terminals (+S, -S, +E, GND) and connecting the module's output (Voltage output, Current output) and power (24VDC) to a collector device.

Figure 3: Interface Definition Table. This table details the input signal wiring identification (+S: Signal+, -S: Signal-, +E: Excitation power supply+, GND: Excitation power supply-). It also defines the output signal wiring identification (VIN: Power supply+, GND: Power supply-, OUT: 4-20mA output, 0-5V, 0-10V for respective voltage outputs).
Important Notes on Wiring:
- The output excitation power supply voltage is 12V.
- Current and voltage outputs are relative to GND.
- Ensure correct polarity for power supply connections (VIN and GND).
- Connect the sensor to the left 4 terminals (+S, -S, +E, GND).
- Connect power and output signals to the right 5 terminals (VIN, GND, OUT, 0-5V, 0-10V).
2.4 Adjustments
The module features adjustable potentiometers for zero and full-scale calibration. These can be fine-tuned to match the specific requirements of your sensor and application, ensuring accurate readings across the desired measurement range.
3. Operating Instructions
Once properly wired and powered, the JY-S65 module will amplify and condition the signal from your connected load cell or strain sensor. The module provides a stable and high-precision output signal based on the sensor's input.
- Output Signals: The module can output 0-5V, 0-10V, 4-20mA, or 0-20mA, depending on the configuration and specific output terminals used. The true output for voltage signals is 0V at the minimum range.
- Indicators: The module is equipped with a power supply indicator to confirm it is receiving power, and an output current strength indicator for monitoring the output signal.
- Performance: Utilizes a special instrumentation load cell amplifying chip design and a high-precision op-amp circuit for strong performance, high precision, and good stability.
4. Maintenance
The JY-S65 module is designed for reliable operation with minimal maintenance. To ensure longevity and optimal performance:
- Keep the module clean and free from dust and debris.
- Avoid exposing the module to excessive moisture, extreme temperatures, or corrosive environments.
- Ensure all connections remain secure.
- Do not attempt to open or modify the module, as this may void any potential warranty and could damage the device.
5. Troubleshooting
If you encounter issues with the JY-S65 module, consider the following:
- No Power Indicator: Check the DC12-24V power supply connection and ensure it is providing the correct voltage. Verify polarity.
- No Output/Incorrect Output:
- Verify all sensor and output wiring connections are correct and secure according to the diagrams.
- Ensure the sensor itself is functioning correctly.
- Check the zero and full-scale adjustments; they might need recalibration.
- Confirm the load cell sensitivity is above 0.1mV/V.
- Unstable Output: Ensure the power supply is clean and stable. The module uses inductors and capacitors to filter power supply ripples, but external interference can still affect performance.
If problems persist, contact the seller for further assistance.
6. Specifications
| Parameter | Value |
|---|---|
| Model Number | JY-S65 Load Cell Sensor Transmitter Amplifier Module |
| Brand Name | Ziqqucu |
| Theory | Current voltage transmitter |
| Working Voltage | DC12-24V |
| Output Signal | 0-5V, 0-10V, 4-20mA or 0-20mA |
| Sensor Sensitivity | Above 0.1mV/V |
| Operating Temperature Range | -20 to 80°C |
| Working Environment Humidity | 10%RH-90%RH (non-condensing) |
| Output Type | Weighing Sensor |
| Use | Pressure Sensor |
| Protection Features | Reverse connection protection, surge protection |
7. User Tips
Based on available information, no specific user tips or common usage advice were found in buyer reviews or Q&A sections for this product. Users are encouraged to follow the detailed wiring instructions and calibrate the module carefully for optimal performance in their specific applications.
8. Warranty and Support
Warranty information for the JY-S65 Load Cell Sensor Transmitter Amplifier Module is not provided in the product description. For details regarding warranty coverage, technical support, or any product-related inquiries, please contact the seller directly.